• 제목/요약/키워드: Power conditioning operation

검색결과 227건 처리시간 0.026초

2차전지 전력저장시스템의 제어기 설계 (Design of Controllers for Battery Energy Storage System)

  • 한석우;전윤석;최규하;목형수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.431-434
    • /
    • 1999
  • This paper presents design of controllers for battery energy storage system. The proposed battery energy storage system can be controlled to operate in the power conditioning mode or the inverter mode. The operation of this mode further divided into three cases: (a) in the peak load period, the load power supplied from the utility is minimized as far as possible; (b) in the off-peak load period, the utility supplies power to the load and charges the battery bank with automatic charging control; (c) in the medium load period, to save battery energy the real power flow out of the battery energy storage system is minimized. Besides, in all cases, the proposed battery energy storage system also automatically compensates the harmonics, subharmonics and reactive power factor in the utility side are much improved. Simulation results are presented by the effectiveness of the proposed controllers for battery energy storge system.

  • PDF

원자력발전소 비상디젤발전기 상태감시 기술 적용 연구 (Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant)

  • 최광희;박종혁;박종은;이상국
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

Soft-Switching Three-Level Chopper-Inverter for High-Power Applications

  • Lee, D.H.;Peng, D.;Lee, F.C.;Borojevic, D.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.56-61
    • /
    • 1998
  • A soft-switching three-level chopper-inverter system was built for high-power applications like Power Conditioning System (PCS) for Superconductive Magnetic Energy Storage (SMES). The system can handle 1800-VDC, 200-A peak, and 250-kW output power. The system was designed to operate with 20-KHz PWM operation with the aid of state-of-the-art zero-current transition type soft-switching. The system is based on the Power Electronics Building Block (PEBB) concept.

  • PDF

에너지 저장장치를 포함하는 태양광 발전시스템의 운전알고리즘 (A Study on Operation Algorithm for PV System with Energy Storage System)

  • 서현욱;변병주;김동진;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.122-123
    • /
    • 2013
  • 본 논문에서는 배터리를 포함한 태양광 발전 시스템에 직류배전 기능을 추가하여 효율적인 전력운용이 가능한 UPCS (Universal Power Conditioning System)의 구성 및 운용 알고리즘을 제안한다. 제안된 알고리즘과 토폴로지는 시뮬레이션을 통하여 기능을 검증하고 실제 가정용을 대상으로 3kW의 시제품을 제작하여 성능을 검증한다.

  • PDF

한국형고속열차 보조전원장치 특성시험 (A characteristic test of Auxiliary power supply for High Speed Rolling stock 350 experimental (HSR-350x))

  • 정상훈;김동환;이병송;이태형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.185-191
    • /
    • 2006
  • Auxiliary power supply developed by domestic technology has very important function that not only effect on main power converter & inverter system, traction motor and train control system which are related to performance of train, but also influence on power supply for HVAC(Heat, Ventilation, Air-conditioning) and lighting device which are related to comfort of passengers. This paper shows characteristic test results of auxiliary power supply such as working condition and performance, which is associated with velocity of train, operating mode and surrounding equipment, through test running. Also it shows the results deduced from comparison analysis between designed data and manufactory test data as measuring in put voltage of auxiliary power supply. And, it propose a modification of design parameter for stabilizing operation and improving reliability.

  • PDF

한국형고속열차 보조전원장치 특성시험 (A characteristic test of Auxiliary power supply for High Speed Rolling stock 350 experimental (HSR-350x))

  • 김동환;이병송;이태형;정상훈
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.84-87
    • /
    • 2007
  • Auxiliary power supply developed by domestic technology has very important function that not only effect on main power converter & inverter system, traction motor and train control system which are related to performance of train, but also influence on power supply for HVAC(Heat, Ventilation, Air-conditioning) and lighting device which are related to comfort of passengers. This paper shows characteristic test results of auxiliary power supply such as working condition and performance, which is associated with velocity of train, operating mode and surrounding equipment, through test running. And, it propose a modification of design parameter for stabilizing operation and improving reliability.

300 kW급 소형 열병합발전기용 배열회수 시스템의 실증운전 성능분석에 관한 연구 (Observation Studies on Field Operation of a Exhausted Heat Recovery System for a 300 kW Class Small Gas Engine Cogeneration System)

  • 김민성;백영진;박성룡;나호상
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.248-257
    • /
    • 2010
  • An exhausted heat recovery system for a small gas engine cogeneration plant was investigated. The system was designed and built in a 300 kW class cogeneration demonstrative system. The basic performance was tested depending on load variation, and installed to a field site as a bottoming heat and power supply system. The exhaust gas heat exchangers (EGHXs) in shell-and-tube type and shell-and-plate type were tested. The entire efficiency of the cogeneration system was estimated between 85 to 90% under the 100% load condition, of which trend appears higher in summer due to the less thermal loss than in winter. Power generation efficiency and thermal efficiency was measured in a range of 31~33% and 54~57%, respectively.

석탄화력 보일러 연소열성능 해석 : 온도와 열에너지 분포를 중심으로 (Computational Studies on the Combustion and Thermal Performance of the Coal Fired Utility Boiler : Temperature and Thermal Energy Distribution)

  • 서상일;박호영;이성노
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.157-166
    • /
    • 2009
  • The pulverized coal combustion behavior in the coal fired utility boiler has been investigated with the CFD and process analysis techniques. The used commercial software were CFX and PROATES, and these were coupled each other to get more reliable boundary condition set-up, resulting in more reliable solution. For two cases which were the actual operation condition of A power plant, the calculated values from the coupled CFD and process analysis for thermal energy system were compared with the plant data, and the good agreements were obtained for Case 1 and 2. The calculated temperature distributions on the surface of heat exchangers were compared with the plant data for the steam temperatures across heat exchangers, and these explained the actual operating situation very well. The temperature deviation across the final superheater tube, which was believed to be the main cause of the frequent tube failure, were also explained very well with the calculated distributions of gas temperature and radiation on the plane of the final superheater.

장기간 사용한 12%Cr강 보일러 튜브의 산화스케일에 관한 연구 (A Study on the Oxide Scale of the Long Term Serviced 12%Cr Boiler Tube Steel)

  • 김범수;민택기
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.281-287
    • /
    • 2012
  • The internal oxide scale of twelve superheater and reheater tubes were tested which were serviced for 30,000~120,000 hours in thermal power plants. The oxide scale was formed in three layers. The Cr-rich area was observed beneath the original metal surface. The hematite ($Fe_2O_3$) phase was formed on the outer surface. The intermediate layer was magnetite ($Fe_3O_4$). The thickness of Cr-rich layer was about half of the total scale. All layers grew during the operation hour of the plant. The thickness of thickest scale was 0.2mm in superheater tubes. This can increase the tube metal temperature about $7^{\circ}C$ more than initial state. $7^{\circ}C$ tube metal temperature can reduce tube life about 30%, but the boiler tube's design margin is big enough therefore it has been analyzed that it would not effect on the life span.

200 W급 휴대용 고분자 전해질막 연료전지 시스템 개발 (Development of a 200 W Portable PEM Fuel Cell System)

  • 한훈식;김윤호;조창환;김서영;현재민
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.91-101
    • /
    • 2012
  • A 200 W portable polymer electrolyte membrane fuel cell (PEMFC) system is developed. The PEMFC system consists of an air-cooled fuel cell stack module, a fuel supply subsystem, a power management subsystem, and a control electronics subsystem. The control logic is designed for the stable system operation. The system-level performance evaluation discloses that the present PEMFC system provides a rated power output of 200.5 W at 13.4 V with the maximum balance-of-plant (BOP) efficiency of 72%, and maximum system efficiency based on lower heating value (LHV) is 37% at 120.7 W system power output.