• 제목/요약/키워드: Power balance

검색결과 1,156건 처리시간 0.024초

발목, 무릎 근력과 균형의 상관관계 (The Correlations among the Balance the Knee and Ankle Muscle Power)

  • 정영준
    • 대한정형도수물리치료학회지
    • /
    • 제16권2호
    • /
    • pp.82-87
    • /
    • 2010
  • Purpose : This study was investigate The correlations between the Balance and the knee muscle power and the ankle muscle power. Methods : This studied selected 9cases of the healthy persons. Each measure of muscle power used Bio-dex pro-3. Balance measure was used balance-meter the ability to measure Ant-post, lateral, overall balance. Result : 1. Knee flexor and extensor causes ankles that plantar flexion strength and high correlation r= .745, r= .825 have, Ankle dorsi flexor strength and a bit of correlation r= .249, r= .221) have. 2. Ankle plantar flexor strength and overall balance and correlation was the r= .204, Ankle dorsi flexor strength and lat. balance and correlation was the r= .314. 3. Knee extensor strength and overall balance and correlation was the r=.212.

  • PDF

DC-Link Voltage Balance Control in Three-phase Four-wire Active Power Filters

  • Wang, Yu;Guan, Yuanpeng;Xie, Yunxiang;Liu, Xiang
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1928-1938
    • /
    • 2016
  • The three-phase four-wire shunt active power filter (APF) is an effective method to solve the harmonic problem in three-phase four-wire power systems. In addition, it has two possible topologies, a four-leg inverter and a three-leg inverter with a split-capacitor. There are some studies investigating DC-link voltage control in three-phase four-wire APFs. However, when compared to the four-leg inverter topology, maintaining the balance between the DC-link upper and lower capacitor voltages becomes a unique problem in the three-leg inverter with a split-capacitor topology, and previous studies seldom pay attention to this fact. In this paper, the influence of the balance between the two DC-link voltages on the compensation performance, and the influence of the voltage balance controller on the compensation performance, are analyzed. To achieve the balance between the two DC-link capacitor voltages, and to avoid the adverse effect the voltage balance controller has on the APF compensation performance, a new DC-link voltage balance control strategy for the three-phase four-wire split-capacitor APF is proposed. Representative simulation and experimental results are presented to verify the analysis and the proposed DC-link voltage balance control strategy.

화력발전시스템 Heat and Mass Balance 최적설계 자동화기법 (Automation of Heat & Mass Balance Design Optimization Method for Power Plant)

  • 백세현;장지훈;김영주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.181-188
    • /
    • 2019
  • 본 연구에서는 발전시스템의 설계 입출력변수들을 Heat & Mass balance 계산 solver 및 최적화 알고리즘과 연계하고 반복계산 과정을 자동화함으로써 기술 및 경제적 측면을 고려한 최적의 발전시스템 Heat & Mass balance 설계를 도출하는 최적설계 자동화 기법을 개발하였다. 그리고 이에 대한 효과를 분석하기 위하여 발전소 형식별 10종에 대하여 최적설계 기법을 적용한 결과, NPV 및 IRR에 대한 개선 효과를 기대할 수 있었다.

세력균형(power balance)에서의 군사력 수준과 동북아시아에 주는 함의 (Balance of Power and the Relative Military Capacity - Empirical Analysis and Implication to North East Asia -)

  • 김명수
    • Strategy21
    • /
    • 통권38호
    • /
    • pp.112-162
    • /
    • 2015
  • This study began to confirm or review the balance of power theory by applying scientific methods through experiential cases. Though there are several kinds of national power, this study supposes military power as a crucial power when it comes to war and peace. This research covered balance and imbalance through comparing relative military power between nations or nations' group. Comparison of relative military power can be achieved by statistically processing the values of which has been converted into the standard variables in same domain, then calculating the values of nation's power which has been synthesized different experiential factors. In addition, the criteria of experiential experiment is highly dedicated to European countries, USA, Japan prior to 1st and 2nd World War, as well as USA, Soviet Union and North East Asia during Cold War era. In addition, the balance of power theory has been redefined to review the action of the state upon the changes of power as mentioned in the theory. To begin with, the redefined theory states that relative level of military power between nations defines the consistency of peace and balance of power. If military power is enough to be on the range of level required to keep the power in equilibrium, peace and balance can be achieved. The opposite would unbalance the military power, causing conflicts. While the relative military level between nations change, nations seek to establish 'nations group' via military cooperation such as alliance, which also shift relative military power between nations group as well. Thus, in order to achieve balance of power, a nation seeks to strengthen its military power(self-help), while pursuing military cooperation(or alliance). This changes relative military power between nations group also. In other words, if there exists balance of power between nations, there is balance of power between nations group as well. In this theory, WWI and II broke out due to the imbalance of military force between nations and nations group, and reviewed that due to the balance of military force during the Cold War, peace was maintained. WWI was resulted from imbalance of military cooperation between two powerful states group and WWII was occurred because of the imbalance among the states. Peace was maintained from cooperation of military power and balance among the states during the Cold War. Imbalance among continental states is more threatening than maritime states and balance of power made by army force and naval force also is feasible. Also the outcomes of two variables are found military power balanced ratio of military power for balance is 67% when variable ratio of balance is 100% and standard value for balance is 0.86. Military power exists in a form of range. The range is what unstabilized the international system causing nations to supplement their military powers. These results made possible the calculation and comparison between state's military power. How balance of power inflicted war and peace has been studied through scientific reviews. Military conflict is highly possible upon already unbalanced military powers of North East Asian countries, if the US draws its power back to America. China and Japan are constantly building up their military force. On the other hand, Korean military force is inferior so in accordance to change of international situation state's survival could be threatened and it is difficult to achieve drastic increase in military force like Germany did. Especially constructing naval force demands lots of time; however but has benefit that naval force can overcome imbalance between continental states and maritime states.

The Effect of Balance between General Walking Exercise and Power Walking Exercise

  • Kim, Shin Gyun;Kim, Chang Sook
    • 국제물리치료학회지
    • /
    • 제4권2호
    • /
    • pp.566-572
    • /
    • 2013
  • This study aims to compared effect of balance between general walking exercise and power walking exercise. Twenty subjects were classified into two groups, general walking exercise(n=10) and power walking exercise(n=10). As a result, two group showed difference within the group and there is significant difference between two groups. 1) In compared static balance of sway area at pre-post test to exercise group, general walking exercise group did not change significantly. however, power walking exercise group did change significantly. and At sway distance, two group showed significant changes. 2) In compared Static balance between the groups sway area and sway path at pre-post test, two group showed significant changes. 3) In compared dynamic balance of center distance at pre-post test to exercise group, general walking exercise group was no significant difference in all directions. power walking exercise group was significant difference in all directions. 4) In compared dynamic balance between the groups sway area and sway path at pre-post test, there was no significant difference in leftward, rightward, forward directions and was significant difference in backward, overall direction. Therefore, power walking exercise can be recommended promote balance.

공통 DC단을 갖는 복합발전시스템을 위한 전력균형제어에 관한 연구 (A Study on Power Balance Control for Hybrid Power System with Common DC Link)

  • 정병환;조준석;고재석;최규하;김응상;이창성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.181-185
    • /
    • 2002
  • This paper discusses power balance control of photovoltaic/wind/diesel hybrid generation system for remote area power supplies. There are many control methods for hybrid power system. Among others, it must be adopted that the control method to guarantee a stable balance between supply and demand, regardless of the fluctuation of generator power by atmospheric changes. In this paper, it Is proposed that a hybrid generation system has a power-balanced controller to equilibrate generation power with a load demand, which is composed of DC bus-type power systems. To execute power balance control, it is assumed that all of power generators have a equivalent current-source characteristics. Through the results of simulation, the proposed scheme was verified.

  • PDF

Development of the Power Simulation Tool for Energy Balance Analysis of Nanosatellites

  • Kim, Eun-Jung;Sim, Eun-Sup;Kim, Hae-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • 제34권3호
    • /
    • pp.225-235
    • /
    • 2017
  • The energy balance in a satellite needs to be designed properly for the satellite to safely operate and carry out successive missions on an orbit. In this study, an analysis program was developed using the MATLAB(R) graphic user interface (GUI) for nanosatellites. This program was used in a simulation to confirm the generated power, consumed power, and battery power in the satellites on the orbit, and its performance was verified with applying different satellite operational modes and units. For data transmission, STK(R)-MATLAB(R) connectivity was used to send the generated power from STK(R) to MATLAB(R) automatically. Moreover, this program is general-purpose; therefore, it can be applied to nanosatellites that have missions or shapes that are different from those of the satellites in this study. This power simulation tool could be used not only to calculate the suitable power budget when developing the power systems, but also to analyze the remaining energy balance in the satellites.

파워 스티어링 기어의 밸브 밸런스 테스트 장비 개발 (Development of Valve Balance Test Equipment for Power Steering Gear)

  • 고석조;박민규;원태현;김현식;김갑혁
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.65-71
    • /
    • 2011
  • Steering gear is the part of an automobile that change circular movement of steering wheel to lateral movement of rack to change driving direction. This can be classified with manual and power steering gear. Manual steering gear is operated only with human power while power steering gear use oil pressure support. These days power steering gear is more common to almost of the car. Recently a korean company manufactures a speed sensitive power steering which provide variable steering feel depend on the speed of car. The Broens company of Australia produces and exports the test equipments for the manufacture of power steering valves and assemblies to major vehicle manufactures. Some korean companies imported the test equipments from Australia, thus increasing the cost. The purpose of this study is development of the valve balance test equipment to measure the valve torque of the power steering gear. This study designed and manufactured the valve balance test equipment to take hold of the power steering valve using CAE analysis. In order to evaluate the performance of the developed valve balance test equipment, the R&R tests have been conducted.

Energy Balance and Power Performance Analysis for Satellite in Low Earth Orbit

  • Jang, Sung-Soo;Kim, Sung-Hoon;Lee, Sang-Ryool;Choi, Jae-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권3호
    • /
    • pp.253-262
    • /
    • 2010
  • The electrical power system (EPS) of Korean satellites in low-earth-orbit is designed to achieve energy balance based on a one-orbit mission scenario. This means that the battery has to be fully charged at the end of a one-orbit mission. To provide the maximum solar array (SA) power generation, the peak power tracking (PPT) method has been developed for a spacecraft power system. The PPT is operated by a software algorithm, which tracks the peak power of the SA and ensures the battery is fully charged in one orbit. The EPS should be designed to avoid the stress of electronics in order to handle the main bus power from the SA power. This paper summarizes the results of energy balance to achieve optimal power sizing and the actual trend analysis of EPS performance in orbit. It describes the results of required power for the satellite operation in the worst power conditions at the end-of-life, the methods and input data used in the energy balance, and the case study of energy balance analyses for the normal operation in orbit. Both 10:35 AM and 10:50 AM crossing times are considered, so the power performance in each case is analyzed with the satellite roll maneuver according to the payload operation concept. In addition, the data transmission to the Korea Ground Station during eclipse is investigated at the local-time-ascending-node of 11:00 AM to assess the greatest battery depth-of-discharge in normal operation.

Correlation between Uni-standing Balance Ability, Jumping Ability, and Anaerobic Lower Extremity Muscle Power of High School Taekwondo Players

  • Jeong, Mo-beom
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권4호
    • /
    • pp.457-462
    • /
    • 2021
  • Objective: This study analyzed the correlation between uni-standing balance ability, jumping ability, and anaerobic lower extremity power of high school Taekwondo players. Design: Cross-sectional study Methods: Two high schools recruited 36 taekwondo players, but 5 were dropped due to personal circumstances and preparations for the tournament, so the number was counted as 31. In order to test uni-standing balance ability, the Romberg test was performed using Biorescue to measure the sway area. In order to test jumping ability, standing long jump and standing highjump were measured. For anaerobic lower extremity muscle power test, the peak power and average power were measured through 30-second pedaling using a Wingate system bicycle. Results: Participants did not show any correlation with other measures in the uni-standing balance ability test (p>0.05). Looking at the correlation in the standing long jump, standing high jump (r=0.892, p<0.05), anaerobic peak power (r=0.698, p<0.05), anaerobic average leg power (r=0.662, p<0.05) showed a positive correlation. Looking at the correlations in the standing high jump, anaerobic peak power (r=0.663, p<0.05), anaerobic average power (r=0.697, p<0.05) showed a positive correlation. Looking at the correlation in the anaerobic peak power, average power (r=0.785, p<0.05) showed a positive correlation. Conclusions: This study shows that balance ability and anaerobic leg strength are independent of each other. The results of this study can be used as basic data for the training plan of high school taekwondo players in the future.