• 제목/요약/키워드: Power arc test

검색결과 121건 처리시간 0.027초

신경회로망을 이용한 LIF 및 HIF검출에 판한 연구 (A Study on the Detection of LIF and HIF Using Neural Network)

  • 최해술;박성원;채종병;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.924-926
    • /
    • 1997
  • A high impedance fault(HIF) in a power system could be due to a downed conductor, and is a dangerous situation because the current may be too small to be detected by conventional means. In this paper, HIF(High impedance fault) and LIF(Low impedance fault) detection methods were reviewed. No single defection method can detect all electrical conditions resulting from downed conductor faults, because high impedance fault have arc phenomena, asymmetry and randomness. Neural network are well-suited for solving difficult signal processing and pattern recognition problem. This paper presents the application of artificial neural network(ANN) to detect the HIF and LIF. Test results show that the neural network was able to identify the high impedance fault by real-time operation. Furthermore, neural network was able to discriminate the HIF from the LIF.

  • PDF

EMTP를 이용한 전압 불안정 현상의 동적 시뮬레이션 (A Dynamic Simulation at Voltage Instability using EMTP)

  • 허정용;권오상;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.131-133
    • /
    • 2003
  • Voltage instability has been studied for some decade now. But, there is not generally accepted definition of voltage instability because of the complex phenomenon and the variety of ways in which it can manifest itself. Both IEEE and CIGRE have the respective definitions. The areas of voltage instability research arc the analysis, simulation and countermeasure of voltage instability. In this paper, we perform a dynamic simulation of voltage instability and voltage collapse using EMTP MODELS. The exponential load model is designed with MODELS and this load model is connected with test power system. The result shows the process of voltage change in time domain when the voltage instability or voltage collapse occurs.

  • PDF

팬구동용 저압 8/6 SRM의 설계 및 구동 특성 (Design and Drive Characteristics of Low Voltage 8/6 SRM for Fan Application)

  • 안진우
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1371-1376
    • /
    • 2014
  • In this paper, 4-phase switched reluctance motor(SRM) with 8-stator and 6-rotor pole structure is proposed for a high speed fan with a low voltage. The air blower has unidirectional rotation characteristics and requires a low torque ripple and noise as well as high efficiency. To achieve the requirements, voltage and current according to loading condition of limited specification is considered. Design process is to select the bore diameter, pole arc, york of stator and rotor to get a high torque and efficiency. To verify the validity of the proposed structure, finite element method(FEM) is employed to get the performances. And the converter for the proposed SRM is employed a 1.5q power converter for cost effectiveness. Prototype SRM is manufactured and tested, and the test results show this design is within the specification and good for the air blower applications.

가공용 가스절연부하개폐기 가속수명시험 (Accelerated life test of SF_6 gas load break switch for overhead line)

  • 박승재;허종철;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.551-553
    • /
    • 2004
  • SF_6 gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, with these trends, SF_6 load break switches have rapidly substituted for the air or oil-type load break switches, in order to get higher reliability. And, the national standard was made for reliability assessment of SF_6 gas load break switch and testing facilities was also set in KERI(Korea Electrotechnology Research Institute ). This paper introduces the synopsis for the reliability assessment requirements specified in the standard and the assessment results.

  • PDF

유리 파단면의 화재감식에 관한 실험적 연구 (An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass)

  • 문용수;공하성
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

유리 파단면의 형태 식별에 따른 파손원인 감정에 대한 연구 (A study on the identification of the causes according to the broken plane types of glass)

  • 문용수;사상열;최민석;최재호;김용수
    • 한국화재조사학회지
    • /
    • 제3권1호
    • /
    • pp.12-15
    • /
    • 2003
  • The purpose of this study is to distinguish the causes of broken glass from doors or windows when it is found being originally kept among the remains on the floor in fire site - whether it was broken due to heating or by outer power through test and the properties of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics for judging the point and direction of breakdown through the analysis of glass broken by outer power. With two causes assumed - a. breakdown due to heating and b. breakdown due to outer power - 3 pieces of glass plates $(30cm{\times}30cm{\times}5mm)$ for each case were tested, getting the results as following: 1. For the glass broken due to the change of temperature The broken plane is of slow curve and smooth without any pattern. 2. For the broken due to outer power With the impact point as the center, the shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern 3. Change of the pattern and type of the glass due to outer power The pattern and type of the glass due to outer power shows change due to heatihg.

  • PDF

과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발 (Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance)

  • 김윤현;김영주
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.129-136
    • /
    • 2020
  • 컷아웃스위치(COS: Cut Out Switch 이하 COS)는 전력계통에서 수용가로 전력을 송배전하기 위해 사용되는 변압기의 입력단에 설치되어 사고전류로부터 변압기를 보호하기 위해 설치되는 보호장치이다. COS는 크게 퓨즈링크와 COS몸체 및 접속부로 구성되어 사고전류시 퓨즈링크의 엘리먼트가 용단되어 사고전류를 차단하는 역할을 한다. COS 퓨즈링크가 용단되어 발생하는 강력한 아크가 화염과 소음을 유발시켜 주변지역 거주자에게 불쾌감 및 공포감을 주며, 아크화염으로 인하여 주변기기의 2차 피해를 유발시킬 수 있다. 본 논문에서는 COS 동작 시 발생되는 아크와 소음 및 보호협조의 문제점을 해결하기 위해 폭발형이 아닌 한류형 COS 퓨즈를 개발하였다. 또한 과전류 차단 기능이 없는 한류형 퓨즈의 단점을 개선하기 위해 퓨즈 엘리멘트, 스트라이커와 COS 퓨즈금구 개발을 통하여 과전류 차단성능의 신뢰성을 향상시켰다. COS의 동작 특성 향상은 퓨즈 엘리멘트의 최적 형상 도출, 스트라이커의 원활한 동작을 위한 동작선의 재질과 두께 및 저항 산정, 그리고 스트라이커와 연계된 하부금구류의 구조 개선을 통하여 수행하였다. 본 연구에서 개발한 COS 퓨즈링크는 공인기관의 시험을 통하여 차단성능과 보호협조 성능을 검증하였다. 시험은 본 연구의 한류형 COS와 기존의 폭발형 비한류형 COS의 비교 시험으로 수행하였다.

차단성능 평가해석기법을 적용한 강자계 구동방식의 460[V]/225[A]/50[kA]급 한류형 MCCB 소호부 개발 (Development of 460[V]/225[A]/50[kA] Contact System in Current Limiting MCCB using an estimation and analysis method for the interrupting capability)

  • 최영길;박찬교
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.78-84
    • /
    • 2004
  • 배선용 차단기(MCCB)는 신속한 고장전류 차단과 전원시스템의 안정성을 확보하기 위해 배선시스템에 폭넓게 사용되고 있다. 본 논문에서는 MCCB의 소호부 형상에 따른 차단성능을 파악하고 이를 통해 성능향상을 꾀하고자 3차원 자계해석을 이용한 차단성능 평가해석기법을 개발하고, 개발한 평가해석기법을 각 모델 차단기에 적용한 바를 기술하였다. 또한, 소호부내 아크런너의 형상을 불연속 통전경로로 구성하여 차단성능에 미치는 영향을 살펴보았다. 이상의 연구내용을 토대로 새로운 소호부 형상을 고안하여 국내 최초로 460 [V]/225 [A]/50 [kA] 대전력 단락시험에 성공한 결과를 제시하였다.

플라즈마를 결합한 바이오 트리클링 시스템에 의한 휘발성 유기물질의 제거 (Removal of Volatile Organic Compounds Using a Plasma Assisted Biotrickling System)

  • 김학준;한방우;김용진
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.727-733
    • /
    • 2007
  • In this study, a newly developed biotrickling system, combined with a non-thermal plasma reactor, was investigated to effectively treat gaseous contaminants such as VOCs (Volatile Organic Compounds). Three kinds of non-thermal plasmas (NTPs) such as a rod type dielectric barrier discharge (DBD) plasma, a packed bead type DBD plasma and a gliding arc (GA) plasma, were tested and compared in terms of power consumption. The rod type DBD plasma was selected as one for integration with biotrickling system due to its relatively high VOC removal efficiency, low power consumption and low pressure drop. Toluene and xylene as representatives of VOCs were used as test gases. The experiment results showed that the efficiency of biotrickling system was especially very low at the high gas concentration and high flow rate and the removal efficiencies of VOCs were considerably enhanced in the biotrickling system, when the DBD plasma was worked in front of that even at the high gas concentration and high flow rate.

냉각수 배관 용접부 평가를 위한 유도초음파 기술의 적용 (Application of Guided Ultrasonic Wave Technology for Evaluation of Welding Part in Cooling Water Pipe)

  • 길두송;안연식;박상기
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.36-40
    • /
    • 2010
  • The ultrasonic guided wave propagates along with the given structure's wall direction. Because of this specific character, the ultrasonic guided waves arc used in many other fields. Especially, it can be readily utilized for nondestructive inspection of various structures that are made up of gas pipes, heat exchanger tubes, and thin plates. Further, the guided wave technology can be readily utilized when inspecting pipes or thin plates which pose high risk of the accident but for which the nondestructive inspection itself is impossible because it is difficult to get to them since they are coated or buried underground. In the other hand, conventional ultrasonic testing such as thickness gauging uses bulk waves and only tests the region of structure immediately below the transducer. As a result of the application about inlet and outlet cooling water line using guided wave test, we conformed that the overall corrosions were in the lower side of the 304.8 mm inlet valve and these corrosions were engaged in not locally but through the lower side of the valve line. In the near future, we can expect that the detectable defect size is smaller than before along with the development of the sensing technology.