• Title/Summary/Keyword: Power Transmission line

Search Result 1,395, Processing Time 0.032 seconds

Vector Control of sensorless induction motor using Extended Kalman Filter theory (확장칼만필터 이론을 응용한 속도센서없는 유도전동기의 벡터제어)

  • 오원석;임남혁;홍찬희
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.6
    • /
    • pp.41-48
    • /
    • 1995
  • In field oriented control of Induction motors, speed sensor is required, which reduces the sturdiness of drive system and together with the expenditure of hardware for faultless transmission and processing of sensor signals it causes considerable expenses. These expensive sensors can be replaced by speed sensorless concept. And for good control, the knowledge of the rotor flux component or the rotor resistance are needs. Thus, this paper is based on a Extended Kalman Filter (EKF) that estimates the state variables that are required for the control by only measuring the line voltages and currents of the machine. the rotor time constant and speed estimated by the EKF show satisfactory agreement with the real values, with the simulation approaches.

  • PDF

Energy Consumption - Economic Growth Nexus in Vietnam: An ARDL Approach with a Structural Break

  • NGUYEN, Ha Minh;NGOC, Bui Hoang
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.1
    • /
    • pp.101-110
    • /
    • 2020
  • Energy and energy consumption play an important role in strategies for socio-economic development of the country. In 1995, Vietnam officially entered the 500 kV North-South transmission power line exploits, with a full length of 1,487 km. The purpose of this study is to investigate the breakpoint and the transition effect of energy consumption to economic growth in Vietnam during the period of 1980-1994, and 1995-2016. The Autoregressive Distributed Lag (ARDL) approach and the Bounds test are used to test for the presence of cointegration, whereas the Toda and Yamamoto procedure Granger causality test is used for the direction of causality. The result of the Bounds test validates the existence of cointegration among the included variables. The empirical results provide evidence that energy consumption has a positive impact on the economic growth of Vietnam in the long run. The causality test shows that there is bi-directional causality between energy consumption and economic growth, supported feedback hypothesis. There is a breakpoint in 1995 and the contribution of energy consumption in economic growth in the period of 1995-2016 is lower than the stage 1980-1994. This study suggests Government authorities explore new sources of energy to achieve sustainable economic development in the long run.

The Communication Method at the Auto-Startup System using TCP/IP and VXI and Expert System(G2)

  • Kim, Jung-Soo;Joon Lyon
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.1 no.2
    • /
    • pp.141-146
    • /
    • 1999
  • This paper describes the communication method of an auto-startup system. The Auto-Startup system is designed to operate a nuclear power plant automatically during the startup operation . In general , the operations during startup in existing plant have only been manually controlled by the operator. The manual operation caused to the operator mistake. The Auto-Startup system consists of the Distributed Control System(DCS) and G2 (Expert System). Also, Functional Test Facility(FTF) provides the plant's real-data for an Auto-Startup system. So, it is necessary to develop the communication method between these systems. We developed two methods ; one is a network and the other is a hardwire line. To communicate between these systems (DCS-G2 and DCS-FTF) , we developed the communication program. In case of DCS-FTF, we used the TCP/IP and VXI. BUt, in case of DCS-G2 , we , what it called , developed the bridge program using the GSI(G2 Standard Interface). We test to check the function of the important parameter, in time, for analysis of the developed communication method. The results are a good performance when we check the communication time of important parameter. We conclude that Auto-startup system could save heat-up time about at least 5 hours and reduced the change of the reactor operation and trip.

  • PDF

Novel Polarization Condition of Optical Polarized Beamsplitter with Misaligned Input Interface and Guiding Loss (불연속 입력 경계면과 전송 손실이 있는 광 편파기 설계를 위한 새로운 편파조건)

  • Ho, Kwang-Chun
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.61-68
    • /
    • 2007
  • Using modal transmission-line theory (MTLT), itexplores rigorously the polarization characteristics of TE-TM mode optical polarized beamsplitter with misaligned input interface. To verify the validity of the approach proposed in this paper, a novel polarization condition is defined, and it compares and evaluates with the polarization condition of coupled-mode theory (CMT) used widely. The numerical results reveal that the discontinuity of misaligned input interface has nothing to do with the polarization condition of beamsplitter. Furthermore, the condition of CMT is no longer effective at the asymmetric guiding structures with strong power coupling.

  • PDF

A Study on the Electromagnetic Interference from 765kV Test Line (765kV 시험선로에서의 전자파 장해에 관한 연구)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.1
    • /
    • pp.36-42
    • /
    • 1996
  • In general, EMI(electromagnetic interference) from EHV(extra high voltage) power lines above 50kV cause interference to AM radio and low VHF television reception. This paper describes the results of long-term measurement of RI and TV1 in 765kV, double circule of $6\times29.59mm$(1.65k inches) diammer $480mm^{2}$(Rail) ACSR conductors in suitable for 766kV transmission lines to provide acceptable EMI at 15m fro the beneath of outmost phase.

  • PDF

Fiber Optic Smart Monitoring of Railway Structures (광섬유센서를 이용한 철도구조물의 모니터링)

  • Kim, Ki-Soo;Cho, Sung-Gyu;Kim, Myeong-Se;Kim, Hak-Yeon;Seo, Ki-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.754-760
    • /
    • 2008
  • For monitoring of railway structures, optical fiber sensors are very convenient. The fiber sensors are very small and do not disturb the structural properties. They also have several merits such as electro-magnetic immunity, long signal transmission, good accuracy and multiplicity of one sensor line. Strain measurement technologies with fiber optic sensors have been investigated as a part of smart structure. In this paper, we investigated the possibilities of fiber optic sensor application to the monitoring of railway structures. We expect that the fiber optic sensors have much less noises than electrical strain gauges because of electro-magnetic immunity while railways operate electric power of 22000 volts. Fiber optic sensors showed good durability and long term stability for continuous monitoring of the railway structures as well as good response to the structural behaviors during construction.

  • PDF

Phenomenological Nonlinear Gain Saturation Effect on the Noise Characteristics of a Multi-electrode DBR Laser with Continuous Frequency Tuning (연속 파장 가변시 현상론적인 비선형 이득포화효과가 다전극 DBR 레이저의 잡음특성에 미치는 영향)

  • 이석목;최원준;한일기;김회종;우덕하;김선호;이정일;감광남;박홍이
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.135-141
    • /
    • 1995
  • Phenomenological nonlinear gain saturation effect on the noise characteristics of a multi-electrode DBR laser, when the lasing wavelength changes continuously, is presented theoretically. Using the optical transmission line theory, noise characteristics reliant on output power are analyzed by taking into account both the spontaneous enhancement factor K due to the distribution of the spontaneous emission along the active cavity and the nonlinear gain saturation effect. Spontaneous emission rate was increased due to an increase in injected current into the passive section, which in turn lead to increase in relative intensity noise (RIN) and frequency noise. Phenomenological nonlinear gain saturation was found to have significant effect on RIN and frequency noise characteristics. However. Iinewidth was found to decrease due to a phenomenological nonlinear gain saturation effect. ffect.

  • PDF

Cathode Side Engineering to Raise Holding Voltage of SCR in a 0.5-㎛ 24 V CDMOS Process

  • Wang, Yang;Jin, Xiangliang;Zhou, Acheng;Yang, Liu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.6
    • /
    • pp.601-607
    • /
    • 2015
  • A set of novel silicon controlled rectifier (SCR) devices' characteristics have been analyzed and verified under the electrostatic discharge (ESD) stress. A ring-shaped diffusion was added to their anode or cathode in order to improve the holding voltage (Vh) of SCR structure by creating new current discharging path and decreasing the emitter injection efficiency (${\gamma}$) of parasitic Bipolar Junction Transistor (BJT). ESD current density distribution imitated by 2-dimensional (2D) TCAD simulation demonstrated that an additional current path exists in the proposed SCR. All the related devices were investigated and characterized based on transmission line pulse (TLP) test system in a standard $0.5-{\mu}m$ 24 V CDMOS process. The proposed SCR devices with ring-shaped anode (RASCR) and ring-shaped cathode (RCSCR) own higher Vh than that of Simple SCR (S_SCR). Especially, the Vh of RCSCR has been raised above 33 V. What's more, their holding current is kept over 800 mA, which makes it possible to design power clamp with SCR structure for on chip ESD protection and keep the protected chip away from latch-up risk.

A Study of an Efficient ZigBee Address Assignment Scheme for Home Area Networks of Smart Grid

  • Choi, Dongmin;Chung, Ilyong
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.5
    • /
    • pp.566-576
    • /
    • 2013
  • In Home Area Network (HAN) of the smart grid, Power Line Communication (PLC) technology and ZigBee communication technology can be used in the communication among the Advanced Metering Infrastructure (AMI) devices. However, according to performance evaluation results of the PLC technology, we find that using the PLC technology is unsuitable for the remote meter reading service. It is worth noting that some parts of the PLC are converted to the ZigBee communication technology in Jeju, Korea. Compared with PLC, ZigBee has no restriction of the place, where the equipments can be freely set up, due to the advantage of radio communication. However, number of usable devices will impact the network performance which is depended on the address assignment. In addition, due to the restriction of transmission range among devices, it is difficult to apply the ZigBee address assignment method to the practical circumstance. In this paper, we examine the previous ZigBee address assignment schemes and the corresponding routing algorithms, and propose a novel address assignment scheme compared with the existing methods, the performance of the proposed one is improved. In particular, evaluation results show that the proposed scheme reduces the average number of hop count, the transfer time and the processing time.

Implementation of RFID Monitoring System based on PLC Ship (선박에서의 PLC기반 RFID 모니터링 시스템 구현)

  • Ahn, Byeong-Hoon;Baek, Dong-Won;Yoon, Seon-Tae;Park, Sang-Hwan;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.646-652
    • /
    • 2008
  • Recently, as the ship has undergone a development for smart ship or digital ship. PLC is communication system using the preexistence power line and using PLC as transmission medium to monitoring of equipments is an efficient way to design a system for ship. In this paper, we design and implement RFID monitoring system based on PLC for ship. This proposed system can support monitoring the moving of passenger, crew and important cargo by RHO tag data on shipboard.

  • PDF