• Title/Summary/Keyword: Power Transition

Search Result 1,044, Processing Time 0.034 seconds

Power consumption evaluation of Set-top box mode transition scheme considering passive stand-by mode (수동대기모드를 고려한 셋톱박스 모드전환 기술의 에너지 절감 성능 분석)

  • Kim, Yong-Ho;Kim, Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.4
    • /
    • pp.135-142
    • /
    • 2011
  • This paper proposes a performance evaluation method for power consumption of set-top box (STB) stand-by mode transition schemes. A stand-by mode transition scheme characterizes the timing of mode transition. The timing of mode transition affects the duration of stand-by mode operation, and the power consumptions of STB as well. Recently a fast stand-by mode transition scheme (FMT) has been proposed based on user input for selecting the device to be connected to TV. In this paper, we evaluate power consumption of FMT and a conventional mode transition scheme. For the computation of the duration of stand-by mode operation, the user input events are modeled as Poisson process. Simulation results based on the modeling reveals that the proposed scheme is more effective in power saving than the conventional scheme by up to 30%.

  • PDF

Coal-fired power plants closure and just transition of port labour employment (화력발전소 폐쇄와 항만인력 고용의 공정한 전환)

  • Su-Han Woo;Du-Ri Kim
    • Korea Trade Review
    • /
    • v.45 no.5
    • /
    • pp.55-74
    • /
    • 2020
  • This study examines the policy direction and specific countermeasures for addressing possible port labour issues from the perspective of Just Transition which may be raised by closing coal fired power plants in Korea. Current energy transition policy and port labour policy in Korea are reviewed and case studies in the countries which has experienced closure of coal fired power plants are undertaken. Although it varies from country to country, a similar approach was found that the employment problem of coal fired power plant closures and measures based on Just Transition regime to mitigate the negative impacts that occur in the region are the key to successful transition. It is suggested that countermeasures for port labour should be institutionalized for providing stakeholders with legal stability covering labours not only directly employed by the plants but also employed in entities in the whole supply chains.

Automatic Command Mode Transition Strategy of Direct Power Control for PMSG MV Offshore Wind Turbines (자동 지령모드절환 기능을 갖춘 PMSG MV 해상 풍력 발전기의 직접전력제어 방법)

  • Kwon, Gookmin;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.238-248
    • /
    • 2016
  • In this study, an automatic command mode transition strategy of direct power control (DPC) is proposed for permanent magnet synchronous generators (PMSGs) medium-voltage (MV) offshore wind turbines (WTs). Benchmarking against the control methods are performed based on a three-level neutral-point-clamped (NPC) back-to-back type voltage source converter (VSC). The ramping rate criterion of complex power is utilized to select the switching vector in DPC for a three-level NPC converter. With a grid command and an MPPT mode transition strategy, the proposed control method automatically controls the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. The automatic command mode transition strategy of DPC is confirmed through PLECS simulations based on Matlab. The simulation result of the automatic mode transition strategy shows that the proposed control method of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control methods of MPPT and VOC under a step response. The proposed control method helps provide a good dynamic performance for PMSGs MV offshore WTs, thereby generating high quality output power.

Improved Power Estimation Methodology Based on Signal Transition Density Propagation Behavior (신호 전이 밀도 전파 동작에 기초한 향상된 전력 평가 방법의 연구)

  • Kim, Dong-Ho;Woo, Jong-Jung
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.8
    • /
    • pp.2520-2527
    • /
    • 2000
  • An improved transition density propagation method for power estimation is proposed. The power estimation for the zero delay model is a proper criteria for the.lower boutldlIry for power consumption. A transition propagation method, including the zero delay model as a lower boundary for power stimation was studied. However, there were some redundancy factors in the process of transition density propagation. Hence this paper will explore the transition density propagation behavior to eliminate the redundancy factors and present theirriprQved estimation methodology for the signal transition density. The experiments show that the proposed method has comparably better estimation accuracy than the conventional methods.

  • PDF

Low power and high speed Data-dependent Precharge Suppression DFF (저전력, 고속데이터 의존 프리차지 억제 DFF)

  • 채관엽;기훈재;황인철;김수원
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.240-243
    • /
    • 1999
  • This paper presents a data-dependent precharge suppression(DPS) D-flip-flop(DFF) with precharge suppression scheme according to data-transition probability The main feature of the DPS DFF is that precharge is suppressed when there is no data transition. The proposed DPS DFF consumes less power than the conventional Yuan-Svensson's true single phase clocking(TSPC) DFF when the data-transition probability is low. The simulation result shows that the power consumption is reduced by 42.2 % when the data-transition probability is 30%.

  • PDF

A study of predicting irradiation-induced transition temperature shift for RPV steels with XGBoost modeling

  • Xu, Chaoliang;Liu, Xiangbing;Wang, Hongke;Li, Yuanfei;Jia, Wenqing;Qian, Wangjie;Quan, Qiwei;Zhang, Huajian;Xue, Fei
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2610-2615
    • /
    • 2021
  • The prediction of irradiation-induced transition temperature shift for RPV steels is an important method for long term operation of nuclear power plant. Based on the irradiation embrittlement data, an irradiation-induced transition temperature shift prediction model is developed with machine learning method XGBoost. Then the residual, standard deviation and predicted value vs. measured value analysis are conducted to analyze the accuracy of this model. At last, Cu content threshold and saturation values analysis, temperature dependence, Ni/Cu dependence and flux effect are given to verify the reliability. Those results show that the prediction model developed with XGBoost has high accuracy for predicting the irradiation embrittlement trend of RPV steel. The prediction results are consistent with the current understanding of RPV embrittlement mechanism.

A Study on Full Bridge and Half Bridge Mode Transition Method of LLC Resonant Converter for Wide Input and Output Voltage Condition (넓은 입출력 전압을 위한 LLC 공진형 컨버터의 풀 브리지-하프 브리지 모드 변환 기법 연구)

  • Choe, Min-Yeong;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Kang, Jeong-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.356-366
    • /
    • 2022
  • This paper presents a mode transition method that applies frequency compensation technique of an LLC resonant converter for stable mode transition. LLC resonant converters used in various applications require high efficiency and high power density. However, because of circuit property, a wider voltage gain range equates to a greater circuit loss, so maintaining high efficiency at all voltage gain ranges is difficult. In this case, full bridge-half bridge mode transition method can be used, which maintains high efficiency even in a wide voltage gain range. However, this method causes damage to the circuit through overcurrent by the mode transition. This study analyzes the cause of the problem and proposes a mode transition method that applies frequency compensation technique to solve the problem. The proposed method verifies the stable transition through simulation analysis and experimental results.

Modeling of the State Transition Equations of Power Systems with Non-continuously Operating Elements by the RCF Method

  • Kim, Deok-Young
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.344-349
    • /
    • 2005
  • In conventional small signal stability analysis, the system is assumed to be invariant and the state space equations are used to calculate the eigenvalues of the state matrix. However, when a system contains switching elements such as FACTS equipments, it becomes a non-continuous system. In this case, a mathematically rigorous approach to system small signal stability analysis is performed by means of eigenvalue analysis of the system's periodic transition matrix based on the discrete system analysis method. In this paper, the RCF (Resistive Companion Form) method is used to analyze the small signal stability of a non-continuous system including switching elements. Applying the RCF method to the differential and integral equations of the power system, generator, controllers and FACTS equipments including switching devices should be modeled in the form of state transition equations. From this state transition matrix, eigenvalues that are mapped into unit circles can be computed precisely.

Sensing Model for Reducing Power Consumption for Indoor/Outdoor Context Transition (실내/실외 컨텍스트 전이를 고려한 저전력 센싱 모델)

  • Kim, Deok-Ki;Park, Jae-Hyeon;Lee, Jung-Won
    • Journal of KIISE
    • /
    • v.43 no.7
    • /
    • pp.763-772
    • /
    • 2016
  • With the spread of smartphones containing multiple on-board sensors, the market for context aware applications have grown. However, due to the limited power capacity of a smartphone, users feel discontented QoS. Additionally, context aware applications require the utilization of many forms of context and sensing information. If context transition has occurred, types of needed sensors must be changed and each sensor modules need to turn on/off. In addition, excessive sensing has been found when the context decision is ambiguous. In this paper, we focus on power consumption associated with the context transition that occurs during indoor/outdoor detection, modeling the activities of the sensor associated with these contexts. And we suggest a freezing algorithm that reduces power consumption in context transition. We experiment with a commercial application that service is indoor/outdoor location tracking, measure power consumption in context transition with and without the utilization of the proposed method. We find that proposed method reduces power consumption about 20% during context transition.

A Low Power Algorithm using State Transition Ready Method (상태 전환 준비 방법을 이용한 저전력 알고리즘)

  • Youn, Choong-Mo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.9
    • /
    • pp.971-976
    • /
    • 2014
  • In this paper, we proposed a low power algorithm using state transition ready method. The proposed algorithm defined a sleep state, a idle state and a run state for the task. A state transition occurring at the time due to the delay time created in order to reduce the power consumption state in the middle of each inserted into the ready state. The ready state considering a power consumption and a delay time in state transition. A scheduling step of performing the steps in excess of the increasing problems have the delay time is long. The power consumption increased for the operation step increase. A state transition from a sleep state with the longest delay time in operating state occurs when the state is switched by the time delay caused by the increase in operating time reduces the overall power consumption reduced. Experiments [6] were compared with the results of the power consumption. The experimental results [6] is reduced power consumption than the efficiency of the algorithm has been demonstrated.