• 제목/요약/키워드: Power System Measurement

검색결과 2,042건 처리시간 0.036초

GPS와 위성통신을 이용한 동기위상 데이터 취득 및 전송장치 개발 (Development of Synchrophasor Data Aquisition and Transmission Systems Using the GPS and the Satellite Network)

  • 권대윤;김호웅;김동성;윤상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.598-599
    • /
    • 2007
  • The electricity supply industry for which high stability and quality of power are the primary aim of power company and the first order of business target. As the facilities of generations, transmissions and substations are increased every year, power system becomes more complex and hard to control. The complexity of the power system causes harmful influence on its security and power facilities. Moreover, difficulty of predicting weather condition in these days with its complexity increases the level of uncertainty of energy demand. Wide area online monitoring of power system offers lots of informations and solutions which clear the causes of insecurity in power system. In this paper, we presents the development of synchrophasor data measurement and transmission system using satellite network for power system online monitoring.

  • PDF

배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험 (A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment)

  • 조진태;김주용;이학주;김재한
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구 (Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication)

  • 이재조;유정훈;홍충선;이대영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권5호
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

산업용 부하설비의 고조파 측정 및 분석 (Harmonics Measurement and Analysis on Industrial Load Installation)

  • 임재윤;이종필;지평식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.110-112
    • /
    • 2003
  • Harmonics happened due to nonlinear systems such as UPS, SCR controlled motors, and fluorescent lighting in distribute power system is very important subject to optimal operate and control of power system. Harmonics sometimes takes place incorrect operation of protective relaying system under normal condition on power system. This paper presents the actual recording data of transformer located at substation of industrial installation for harmonic analysis in detail.

  • PDF

동축 반전 시스템의 공력측정 (Aerodynamic Force Measurement of Counter-Rotating System)

  • 김수연;최종욱;김성초
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.39-42
    • /
    • 2008
  • In the case of the general helicopter among rotorcraft, length of the rotor blade for thrust-generation is longer than that of fuselage and tail rotor is required in order to compensate moment of the fuselage. For those reasons, enough space for take-off and landing should be secured and an accessibility for building is low. Also, the accidents caused by tail rotor occur frequently. However, the case of counter-rotating has merits that tail rotor is unnecessary as well as length of the rotor blade can be shortened but has a weakness that the weight of body is increased. In the present study, aerodynamic force measurement on single rotor system equipped with NACA0012 airfoil, which has aspect ratio of 6 and chord length of 35.5 mm, was carried out. And measurement was conducted with blade which has a half size of the former blade by using single motor counter-rotating. Aerodynamic force measurement was acquired by using 6-component balances and coefficients of thrust and power were derived along the pitch angle varying from 0$^{\circ}$ to 90$^{\circ}$ with the increment of 10$^{\circ}$. Those aerodynamic force data will be utilized for the design and production of brand-new counter-rotating rotor blade system which has same thrust with single blade system and provides a good accessibility to building by reducing its blade length.

  • PDF

이산웨이블릿을 이용한 전력외란 측정 시스템 (Power disturbance measurement system using discrete wavelet transform)

  • 이진목;김홍균;최재호;이상훈
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.527-533
    • /
    • 2003
  • 최근 민감한 전자부하의 사용증대에 기인하여 전직의 안정도와 신뢰도에 대한 관심이 증대되고 있다. 이에 전력풀질문제가 근래에 있어 일반적인 중요한 과제로 대두되었다. 이러한 전력품질문제를 진단하기 위하여 실효치나 FFT 등의 기법을 이용한 많은 알고리즘이 연구되어 왔으나 모든 전력품질문제를 진단하기에는 아직도 미진한 상황이다. 본 논문은 이산 웨이블릿을 응용한 전력품질문제의 진단 방법을 제안하고 웨이블릿의 이론에 대한 기본적인 설명과 함께 제안된 이론의 타당성을 입증하기 위하여 실제 전력품질문제 진단시스템을 설계하고 실험결과를 제시하였다.

Real-Time Maximum Power Point Tracking Method Based on Three Points Approximation by Digital Controller for PV System

  • Kim, Seung-Tak;Bang, Tae-Ho;Lee, Seong-Chan;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1447-1453
    • /
    • 2014
  • This paper proposes the new method based on the availability of three points measurement and convexity of photovoltaic (PV) curve characteristic at the maximum power point (MPP). In general, the MPP tracking (MPPT) function is the important part of all PV systems due to their power-voltage (P-V) characteristics related with weather conditions. Then, the analog-to-digital converter (ADC) and low pass filter (LPF) are required to measure the voltage and current for MPPT by the digital controller, which is used to implement the PV power conditioning system (PCS). The measurement and quantization error due to rounding or truncation in ADC and the delay of LPF might degrade the reliability of MPPT. To overcome this limitation, the proposed method is proposed while improving the performances in both steady-state and dynamic responses based on the detailed investigation of its properties for availability and convexity. The performances of proposed method are evaluated with the several case studies by the PSCAD/EMTDC$^{(R)}$ simulation. Then, the experimental results are given to verify its feasibility in real-time.

전력케이블의 열화측정을 위한 부하전류 및 온도측정 시스템 (Load current and Temperature measurement system for Measuring the Degradation of Power cable)

  • 박용규;조영식;이관우;엄기홍;박대희
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.69-74
    • /
    • 2015
  • Recently, there has been a surge in interest in equipment diagnosis and monitoring technology from the perspective of providing quality electricity in terms of reliability and safety. In order to meet the electrical demands of consumers, reliability of power supply needs to be maintained. For this purpose, a monitoring system for power cable is very important. Since real-time measuring equipment has many advantages, it is highly applicable. By measuring the load current and the surface temperature of power cables, we have monitored and identified the deterioration phenomena of power cables in operation. Since direct measurement of the cable conductor temperature is not easy, we have measured the surface temperature instead, and converted that temperature to obtain the conductor temperature of the cables. In addition, we have designed a system to detect the deterioration processes of the power cables in operation.

모터 구동장치를 위한 DSP기반 3상 전력품질분석 시스템 (A DSP based Three Phase Power Quality Analyzer for Motor Drives)

  • 정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.661-664
    • /
    • 2000
  • This paper presents a digital instrument for the power quality analysis in three phase power system where current waveform is non-sinusoidal. It is based on C31 DSP and on a special high-speed data acquisition system. Voltage and current waveforms are acquired and processed by using a simple average power algorithm, The paper also goes on to discuss the performance of an instrument prototype both in terms of accuracy and speed of measurement.

  • PDF

풍력발전 시스템의 계통연계에 따른 전력품질 모니터링 및 진단 (Power Quality Monitoring and Diagnosis for the Distribution System Interconn of Wind Turbine)

  • 장석명;이성호;윤인기;조한욱;윤기갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.251-253
    • /
    • 2002
  • Various measures of power quality are addressed, specifically power factor, power variability, electrical transients, flicker and harmonics. This paper presents the measurement criteria for monitoring and diagnosis of power quality according to the distribution system interconnection of wind turbine.

  • PDF