• 제목/요약/키워드: Power System Measurement

검색결과 2,042건 처리시간 0.031초

생체신호계측을 위한 체내 이식형 무선송수신 시스템 개발 (Development of a transcutaneous system for implantable bio-signal measurement)

  • 이승하
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.23-28
    • /
    • 2008
  • In order to measure bio-signals, it is desirable to build a fully implantable system which connects directly to neural pathways or body tissue. A design scheme for fully implementable measurement system is proposed in this paper. Consisting of an implanted module and an external system, the proposed scheme delivers power and data between the two modules. The external module sends power via inductive link using a simple H-bridge type oscillator. Also, the implanted module sends measured data to the external system utilizing R/F communication technique at a frequency of ISM band. A stable communication and operation is achieved as the two types of channels are separated. Implemented in a compact size enough to be implanted in human body, the system exhibits good performance in experimental studies.

기계 상태 감시: 임베디드형의 고성능 무선 측정시스템 (Condition Monitoring System: High Performance Wireless Measurement System)

  • 심민찬;양보석
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.28-32
    • /
    • 2007
  • This research proposed that development of wireless condition monitoring system using WLAN network. It offers the prospect of improved performance that removed a current a coaxial cable and reduced overall cost of condition monitoring. Recently, there is an interesting concern for wireless system as an infrastructure technology construct ubiquitous computing environment in the future. High performance computing board makes minimization with integrate of a various functions which support wireless LAN network. Instead of wired coaxial cable using measurement system in industry, wireless LAN network assists industry automation and engineer's convenience. Developed system adapted wireless LAN network on shipboard with engine room and deck house, it also executes wireless measurement test on 8500TEU containership.

  • PDF

전력계통 전력품질 통합진단시스템 개발 (The Development of Integrated Power Quality Diagnosis System for Power System)

  • 곽노홍;전영수;박상호;이일무;박희철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

대지전위 실측에 의한 접지성능 평가 (Estimation of Earth Performance by Ground Potential Measurement)

  • 이원영;김재훈;김주한;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.51-53
    • /
    • 2005
  • Grounding systems are responsible rot the safe operation of a power system whetehr power system fault occures or not, their performance guarantees equipmet protection and personnel safety by limited the ground potential rise and touch voltages as well as step voltages under ground fault condition. therefore, it is necessary to measure the ground resistance frequently for checing the performance of grounding system. In order to verigy the designed grounding measurement system feasibility, two comparison verifications, which are the ground resistnace measurements using the designed system on power service and off power service, are carried out for the same substation.

  • PDF

배전 계통의 고조파 측정 및 DB 구축에 대한 연구 (A study on the measurement of harmonics in the distribution system and the configuration of DB)

  • 박용업;강문호;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.202-203
    • /
    • 2006
  • The equipment using the Power electronic device is recently increased in the distribution system, so power utility and customers increase in concerning about harmonics level. Accordingly, The power utility which prepares a measure for the harmonic public standard and manege process must analysis of the harmonics level and the effect on equipment interconnecting distribution system. In the past, the measurement equipment and technique is imperfect, so very difficult to investigate the harmonics and trend. But the improvement of the measurement equipment recently is possible to obtain the data realtime for harmonic analysis. In this paper, we research the measuring domestic harmonic and constructing of DB based on the IEC standard.

  • PDF

배전선로 규정전압 유지를 위한 전류 측정치 기준의 무효전력 제어방법 (Current Measurement based Reactive Power Control to Mitigate Overvoltage of Primary Distribution Line)

  • 황지희;임성일
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1547-1553
    • /
    • 2017
  • Due to the high penetration ratio of dispersed generations, overvoltage problem of the feeder has become more an important issue in distribution system operation. This paper proposes a new method for the smart inverter to control reactive power to mitigate voltage rise by the reverse power flow from the DGs. The proposed method controls reactive power based on current measurement while conventional methods use voltage measurement which include unacceptably large errors. Various case studies using MATLAB simulation have been performed to verify effectiveness of proposed method.

송전선로 파라메터 정밀 예측을 위한 페이저 측정기의 응용 (Estimation Technique of Power Transmission Line Parameter by Phasor Measurement Units)

  • 조기선;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.193-195
    • /
    • 2003
  • This paper presents an approach to estimate the power transmission line parameter by phasor measurement units(PMUs), which are synchronized to 1 pps signal of GPS. Existing approaches to estimate power transmission line parameter, are mainly off-line ones, based on faults or switching events on other neighboring lines. In this paper, to obtain static and dynamic properties of power transmission line parameter in service, the prototype of pmu-based Transmission Line Parameter Monitoring System (TLPMS) is proposed. Also, an technique to estimate parameters of transmission line described as 2-port network model and the soundness of estimated parameters are addressed.

  • PDF

레이저 간섭계를 이용한 이동형 미세 변위 측정에 관한 연구 (A Study on the Portable Micro Displacement Measurement Using Laser Interferometer)

  • 최경현;양형찬
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.99-103
    • /
    • 2006
  • The laser interferometer has been used for measurement of the micro displacement error. Although the laser interferometer is widely accepted as a tool for measurement of motion accuracy, the set-up procedure is time-consuming because of the strict requirement on alignment between a laser head and optic units. This paper addresses the development of a laser interferometer to measure the micro displacement for a micro machine. The portable laser interferometer which integrates a laser probe and optics, is developed for the convenient measurement. For the experiment, moving mirror set up on the micro stage. The velocity decoding board is also added to calculate doppler shift frequency directly. The output signal is obtained and analyzed by LabView. Finally experiments are found out the relation between micro displacement and output signal.

  • PDF

고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험 (Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement)

  • 장성덕;손윤규;권세진;오종석;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

소규모 전력시스템를 위한 실시간 전원 계측 및 저장 시스템 구현에 관한 연구 (Research for Implementation of Real-time Power Measurement and Storage System)

  • 서종완;서희석;신명철
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.29-36
    • /
    • 2007
  • 태양 전지, 연료 전지 및 소규모 풍력발전 등 소규모 분산 전원의 보급에 따라, 소규모 전력 수용가측의 전원 구성은 종래의 단일 전력 사업자로부터 전원을 공급 받는 방식에서 분산 전원과 연계하여 동시에 사용하는 방식으로 바뀌고 있다. 이에 따라 분산전원을 사용하는 수용가에서는 계통과 연계하여 운전되는 분산 전원에 대한 상시 감시 제어 시스템이 요구된다. 이에 본 논문에서는 감시제어 시스템을 구성하는데 필수적으로 요구되는 계통의 전압, 전류 등을 측정하기 위한 시스템을 구현하였다. 그리고 계통의 정상상태는 물론 전원 투입과 탈락 시, 부하의 급격한 증감 시 발생하는 과도현상 데이터 등을 실시간으로 계측하고, 측정된 데이터들을 여러 가지 목적으로 사용할 수 있도록 USB 통신을 이용 PC로 전송하여 저장한다. 또한 PC에 전송된 데이터를 계측기를 사용한 측정 결과와 비교하여 제작한 시스템의 신뢰성을 검증한다.