• Title/Summary/Keyword: Power System Measurement

Search Result 2,042, Processing Time 0.03 seconds

A Study on the Data Aquisition System for Power Quality Analysis of Load Equipment (부하설비의 전력품질 분석을 위한 데이터 획득시스템에 관한 연구)

  • Yu, Jae-Geun;Lee, Sang-Ik;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.92-94
    • /
    • 2007
  • In order to analyze voltage, current, electrical power, harmonics and so on of electrical load equipments, electrical power analysis by real measurement rather than mathematical modeling is necessary, and plan of countermeasure for efficient management, energy frugality and accident prevention of electrical equipments using it is possible. Especially, electrical power analysis by real measurement is indispensable in order to consider countermove of harmonic occurred by nonlinear load. So, in this paper, we developed DSP(Digital Signal Processor) based low price date aquisition system, and verified it's ability by performing measurement and analysis of electrical power and harmonic in the real power system.

  • PDF

Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor

  • Joo, Sungmoon;Lee, Jong Bok;Seo, Sang Mun
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.203-210
    • /
    • 2018
  • As the modernization of the nuclear instrumentation system progresses, research reactors have adopted digital wide-range neutron power measurement (DWRNPM) systems. These systems typically monitor the neutron flux across a range of over 10 decades. Because neutron detectors only measure the local neutron flux at their position, the local neutron flux must be converted to total reactor power through calibration, which involves mapping the local neutron flux level to a reference reactor power. Conventionally, the neutron power range is divided into smaller subranges because the neutron detector signal characteristics and the reference reactor power estimation methods are different for each subrange. Therefore, many factors should be considered when preparing the calibration procedure for DWRNPM channels. The main purpose of this work is to serve as a reference for performing the calibration of DWRNPM systems in research reactors. This work provides a comprehensive overview of the calibration of DWRNPM channels by describing the configuration of the DWRNPM system and by summarizing the theories of operation and the reference power estimation methods with their associated calibration procedure. The calibration procedure was actually performed during the commissioning of an open-pool type research reactor, and the results and experience are documented herein.

The Study on Development for Small-scale Super-speed Maglev Train (축소형 초고속 자기부상철도 개발에 관한 연구)

  • Han, Young-Jae;Jo, Jung-Min;Lee, Jin-Ho;Kim, Chang-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1497-1503
    • /
    • 2016
  • This paper presents the overall measurement system for on-line test of super-speed maglev train. The super-speed maglev train is composed of vehicle, propulsion, power, and so on. In order to evaluate and diagnose for sub-system, we made overall measurement system. Just like the other measurement system, it is designed to distributed type. The hardware is consist of SCXI, PXI, Terminal, UPS, and so forth. It is installed on a train, control room, power room and track to collect lots of signals. The software controls hardware system, monitors main data such as inverter current, converter voltage. Using the measurement system, we evaluated a lot of performances for vehicle, track, and so forth. Through the developed system have improved reliability and safety for super-speed maglev train.

Measurement of Breaker Noise by Using Breaker Noise Measurement System (브레이커 소음측정시스템을 활용한 소음의 측정 및 평가)

  • Lee, Jae-Won;Kang, Dae-Joon;Gu, J.H.;Park, H.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1173-1176
    • /
    • 2007
  • The breaker noise is one of the main noise sources of construction site. It is very important to assess and measure the breaker noise accurately, because the noise labelling will be in effect January 2008 in Korea. Therefore, It is necessary to measure the sound power level of breakers and use a appropriate test method in accordance with international standard. In this study, we measure the sound power level of breakers by using the breaker noise measurement system. This system makes it possible to measure the breaker noise more accurately than to measure the noise of that attached with excavator, because this system can control main factors affecting breaker noise such as hydraulic input power, hydraulic supply pressure, breaker inlet oil flow and so on.

  • PDF

Measurement of Phasor Angles of Power System using Synchronized Phasor Measurement System (동기위상 측정장치를 이용한 전력계통 위상각 측정)

  • Yi, Kyung-Keuk;Lee, Jae-Wook;Wang, Jae-Myung;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.55-57
    • /
    • 2000
  • This paper presents the measurement of phasor angle of power system using Synchronized Phasor Measurement System(SPMS). SPMS includes the GPS receiver, so it can add the exact time information to the data acquired from the power system by SPMS. Using that data, we can compare the difference of phasor angles of voltages currents acquired at the exactly same time, and monitor the RMS values of voltage and current. In this paper, we present the difference of voltage angles between 345kV Sinjechon S/S and 345kV Asan S/S, where two SPMS were installed separately, and prove their performance by comparing to simulation result of PSS/E.

  • PDF

Measurement System of Pentagraph Slider with Image Processing (이미지 처리기술을 이용한 펜터그라프 섭판 측정장치 개발)

  • 김기택;임기택;김봉택
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.296-301
    • /
    • 1998
  • Pentagraphs are used to supply electric power to train via trolley lines. The higher train speed is, the higher voltage and current levels 8u. Since electric power is supplied with slinding contact, localized abrasion is inevitable. It is difficult and dangerous to measure their shape manually. Measurement system of pentagraph slider with ultrasonic processing has been reported. In this paper, measurement system with image processing is proposed. The system consists of CCD cameras, image grabber board, and PC operated on Windows'95. Image processing algorithms are presented and some results are illustrated.

  • PDF

Capacitive Voltage Divide for a Pulsed High-Voltage Measurement (펄스형 고전압 측정용 용량성 분압기)

  • Jang Sung-Duck;Son Yoon-Kyoo;Kwon Sei-Jin;Oh Jong-Seok;Cho Moo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.63-68
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source are under operation for 2.5 GeV electron linear accelerator in Pohang Light Source (PLS) linac. The klystron-modulator system has an important role for the stable operation to improve an availability statistics of overall system performance of klystron-modulator system. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are demanded for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider (CVD), which divides input voltage as capacitance ratio, is intended for the measurement of a beam voltage of 400 kV generated from the klystron-modulator system. Main parameter to determine standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will be present and discuss the design concept and analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance effects and oil temperature variation.

Development of Code-Domain Power module for CDMA signal (CDMA 신호의 Code Domain Power 모듈 개발)

  • Lee, Young Kyo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 2008
  • This paper describes the measurements that provide a characterization of the code-domain channels of a CDMA base station transmitter. One of the measurements, called code-domain power(CDP), provides the distribution of power in the code domain channels. This measurement can be used to verify that the various channels are at expected power levels and to determine when one code channel is leaking energy into the other code channels. We develop module of CDP measurement in the CDMA system.

Software Reliability of Safety Critical FPGA-based System using System Engineering Approach

  • Pradana, Satrio;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.14 no.2
    • /
    • pp.49-57
    • /
    • 2018
  • The main objective of this paper is come up with methodology approach for FPGA-based system in verification and validation lifecycle regarding software reliability using system engineering approach. The steps of both reverse engineering and re-engineering are carried out to implement an FPGA-based of safety critical system in Nuclear Power Plant. The reverse engineering methodology is applied to elicit the requirements of the system as well as gain understanding of the current life cycle and V&V activities of FPGA based-system. The re-engineering method is carried out to get a new methodology approach of software reliability, particularly Software Reliability Growth Model. For measure the software reliability of a given FPGA-based system, the following steps are executed as; requirements definition and measurement, evaluation of candidate reliability model, and the validation of the selected system. As conclusion, a new methodology approach for software reliability measurement using software reliability growth model is developed.

A Study on Measurement and Analysis of Pilot Channel Power at CDMA Communication Network (CDMA통신망에서 파일롯 채널전력 측정 및 분석에 관한 연구)

  • Jeong, Ki-Hyeok;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.31-39
    • /
    • 2007
  • In this paper, a system for real-time or periodic measurement and analysis of RF parameters such as forward transmit power and pilot power in CDMA base station systems is proposed. Such RF characteristic parameter measurement can be prevented from system fault and used to achieve optimal service quality and maximum investment return through cell coverage expansion, subscriber capacity increase and so on. For forward power measurement, the local oscillator frequency for the detector is varied so that the transmit power for all channels can be measured. The channel power measurement can be used to analyze the variation in transmit power for changes in voice traffic. By comparing to forward $E_c/I_o$, the pilot channel power can be deducted, which can be used to determine uy degradation in transmit section modules such as the high dover amplifier. Since an accurate analysis of carefully measured data using the CDMA level detector must be made, the system is designed so that measurement errors due to changes in crest factor with modulation method can be overcome.