• Title/Summary/Keyword: Power System Equipment

Search Result 2,216, Processing Time 0.032 seconds

The field-test of Power Quality Meter and Power Management System in order to verify the performance (PQM 및 PQMS 성능검증을 위한 실증시험)

  • Choi, Sun-Kyu;Song, Il-Keun;Kwon, Tae-Ho;Han, Jae-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

Process Modeling of the Coal-firing Power Plant as a Testbed for the Improvement of the System and Equipment (화력발전 시스템 및 설비 개선 실증을 위한 열물질정산 공정모델 개발)

  • Ahn, Hyungjun;Choi, Seukcheun;Lee, Youngjae;Kim, Beom Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.23 no.1
    • /
    • pp.44-54
    • /
    • 2018
  • Heat and mass balance process modeling has been conducted for a coal-firing power plant to be used as a testbed facility for development of various plant systems and equipment. As the material and design of the boiler tube bundle and fuel conversion to the biomass have become major concerns, the process modeling is required to incorporate those features in its calculation. The simulation cases for two different generation load show the satisfying results compared to the operational data from the actual system. Based on the established process conditions, the hypothetical case using wood pellet has also been simulated. Additional calculations for the tube bundle has been conducted regarding the changes in the tube material and design.

Design of Characteristics Test Equipment for a Large Capacity Thyristor (대용량 사이리스터 특성평가 장비의 설계 및 제작)

  • Seo Kil-Soo;Kim Hyoung-Woo;Kim Ki-Hyun;Kim Nam-Kun;Kim Eun-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.567-572
    • /
    • 2005
  • Recently, application area of the thyristor is extends to power conversion systems, such as HVDC, BTB, SVC and FACTS. Therefore, reliability diagnostic technique on thyristor is needed to obtain stability and maintenance of power conversion systems. To measure the characteristics of the thyristor, test equipments which based on IEC 747-6 and KS C 7023 standard are needed. In this paper, we presents the design and manufacture of the test equipments for 6.5kV/4.2kA thyristor which used in thyristor valve of HVDC conversion systems by using test standard. Voltage, current, dv/dt and turn-off time test equipments were designed and manufactured. Each systems were made separately, but unity operation can possible.

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members

  • Woo, Sangkyun;Chu, Inyeop;Youn, Byongdon;Kim, Kijung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.293-298
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

Development of Diesel Generator Excitation System in the Nuclear Power Plant (원전 비상디젤발전기 여자시스템 개발)

  • Shin, Man-Su;Ryu, Ho-Seon;Lee, Joo-Hyun;Im, Ik-Heon;Jeong, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.397-406
    • /
    • 2010
  • Because diesel generator excitation systems in the nuclear power generating station are included among safety related c1asses(and Class 1E), they have been supposed to apply in the nuclear power generating stations through equipment qualification by nuclear law and so on. So, they has been controlled and assured completely by quality assurance throughout the total development journey. This paper looks into the journey of development of diesel generator excitation systems in the nuclear power generating station.

Power Management System of Base Station Equipment for Mobile Communications (이동통신 장비의 전력관리 시스템)

  • Kang, Sanggee
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.4
    • /
    • pp.48-51
    • /
    • 2016
  • Many studies have been carried out in order to develop a frequency efficient communication system than the current communication system for satisfying the increasing demands of wireless data services in mobile communication systems. Service providers must maintain a lot of base station equipments to meet the increasing demands of wireless data service. Therefore service provider needs a system or method to reduce maintenance costs. The amount of wireless data service are changed according to the time of day, geographical location and so on. Power consumption can be reduced if the supplied power of communication systems is controlled by the amount of wireless data traffics. In this paper, power management system of base station's equipment for mobile communication is designed and implemented. The proposed power management system controls the power supplied to the mobile communication infrastructures depending on the service amount of wireless data. Field test result of the implemented system shows the proposed system saves 26% of the power consumption in the base stations.

Analysis for the Dynamic Characteristics of the Moving Equipment for the large Radar Transportation (대형 레이더 수송용 이동치구의 주행동특성 분석)

  • Jeon, Jong-Ik;Lee, Jong-Hak;Kang, Young-Sik;Choi, Ji-Ho;Kang, Dong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.416-421
    • /
    • 2013
  • In this paper, the design concept of the transport of defense equipment and processes were established. And the transport of large radar equipment design were investigated. Detailed design of moving equipment with reference to the U.S. military standard was performed.Damping system of the moving equipment by using a simulation designed to predict In order to minimize shock and vibration in the vehicle due to the irregular road surface is transmitted through. Analysis of the damping system was verified using the driving test.

  • PDF

A Study on Chaining Threat Analysis of Cybersecurity against Reactor Protection Systems (원자로보호계통 사이버보안 연계 위협 분석 연구)

  • Jung, Sungmin;Kim, Taekyung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.2
    • /
    • pp.39-48
    • /
    • 2022
  • The application of digital technology to instrumentation and control systems in nuclear power plants has overcome many shortcomings of analog technology, but the threat of cybersecurity has increased. Along with other systems, the reactor protection system also uses digital-based equipment, so responding to cybersecurity threats is essential. We generally determine cybersecurity threats according to the role and function of the system. However, since the instrumentation and control system has various systems linked to each other, it is essential to analyze cybersecurity threats together between the connected systems. In this paper, we analyze the cybersecurity threat of the reactor protection system with the associated facilities. To this end, we quantitatively identified the risk of the reactor protection system by considering safety functions, a communication type, the use of analog or digital-based equipment of the associated systems, and the software vulnerability of the configuration module of the reactor protection system.

Development of Power Performance Evaluation System using Modeling Technology (설비 모델링 기술을 이용한 발전성능평가 시스템 구성방안 연구)

  • Lee, Ji-Hoon;Lee, In-tae;Jung, Nam-Joon;Bae, Jung-Seok;An, Young-Mo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.81-88
    • /
    • 2018
  • Performance evaluation of a plant to efficiently manage and maintain the performance of the plant is a very important procedure. However, since the conventional performance evaluation method is an Excel-based manual method, the preparation procedure is complicated and the versatility is poor. In this paper, we analyze the problems of the existing performance evaluation system, effectively model the equipment, calculate the missing physical properties, and improve the versatility, efficiency and accuracy of the performance evaluation through the equipment modeler which performs automatic index calculation based on this.

Analysis of voltage sag effect at load side during fault according to change of power system condition (계통조건(系統條件) 변경(變更)에 따른 고장시(故障時) 부하측(負荷側)의 순간전압강하(瞬間電壓降下) 영향분석(影響分析))

  • Yoon, Gi-Seob;Baik, Seung-Do;Gu, Sung-Wan;Lee, Chong-Soo;Lee, Hong-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.156-158
    • /
    • 2002
  • In this paper, we analyze about voltage sag effect at load side during fault according to change of power system condition. through the case studies, we find that there is no close connection between substation bus transfer and voltage sag during fault. however, we find that other feeder connecting with the faulted transmission is directly affected by fault type and magnitude, therefore, the main subject can be divided into the utility and customer side countermeasures, utilities concentrate their effort to prevent the faults and to modify the fault clearing practice in power system. however, the faults in power system can never be completely eliminated. therefore, customer side solutions usually involve the power conditioning equipment for sensitive loads aiso, we investigate that the several methods to reduce the number and severity of voltage sag and to dull the sensitivity of equipment for voltage sag have developed. moreover, about SEMI, the industry association for the semiconductor two voltage sag immunity standards.(SEMI F47, SEMI F42) The simulation is accomplished by PSS/E 26.

  • PDF