• Title/Summary/Keyword: Power System Effect

Search Result 3,472, Processing Time 0.033 seconds

The Effect on Real Power System by the Inrush Current of a Transformer (변압기 돌입전류에 의한 실계통 영향 분석)

  • Shin, Jeong-Hoon;Jang, Gil-Soo;Yoon, Yong-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.318-321
    • /
    • 1999
  • This paper describes the study of the effect on real power system due to the inclusion of the MTR at Buk Che-ju TP #2. The test system in which the transformers are represented in detail and rest Che-ju systems are represented as an equivalent system on the bus is simulated by the EMTDC. Simulation results include magnitude of inrush current and voltage drop on the bus at various CB closing time, and they show the effect on Che-ju system by the inrush current of the Buk Che-ju TP #2's MTR is not considerable.

  • PDF

Effect of the Interconnected Solar Power Generation System on the Power Quality of Power System (계통연계형 태양광발전 시스템이 계통의 전력품질에 미치는 영향)

  • Kwon, Dong-Chul;Park, Joong-Sin;Yi, Dong-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.52-58
    • /
    • 2012
  • In this study, we have investigated the effect of the solar power generation facilities on the power quality of interconnected solar power generation system. When the solar power generation facility was connected to the distribution system, whether the solar power generation is under operation or not, Peak factor of current was increased to 0.033[%], Frequency is deviated from $60{\pm}0.2$[Hz] and also Short term flicker indication($P_{st}$) increased to 0.213[p.u.] compare with the disconnected situation. Harmonic current [%] in orders was 11.42[%] maximum under 11th orders and was 7.861[%] between 11th and 17th orders. These values were about 3 or 4 times compared with "the power system interconnection technique standards" at the same situation above. Therefore, we could confirmed that the solar power generation facility, when it was connected to the existing distribution system, made bad influence on the power qualities such as the peak factor of current, frequency regulation, short term flicker indication($P_{st}$) and harmonic current [%] in orders etc.

An Analysis of Power System Stability(PSS) Effect with 135MVA Hydro Generator (135MVA 수력 발전기의 전력 시스템 안정화 장치 적용 효과 분석)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Oh, Sueg-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1100-1104
    • /
    • 2009
  • As national power consumption every year increases, the power plant which is in the process of planning tries to establish high-capacity generator. The power system tends to become a large size. With the progress of electronic components, the control systems of the generator have been digitalized and rapid-response control system is possible. However, the minute frequency vibration of grid occurred with the effect of rapid-response control system. To solve these problem, PPS(Power System Stability) has been introduced since 2004, and it has being installed and applied to the thermal and nuclear power plant which are high-capacity, over 800MVA. However the minute frequency vibration is gradually changed to the bigger frequency vibration by fast-action control system, and this regional frequency fluctuation might be diffused wide area. Therefore, it is applied to the hydro generator which is small with fast-action governor system, and it is necessary to control the minute frequency vibration to prevent to diffuse. In this paper, the effect will be proved by establishing PSS on the Hydro-Generator which has both digital excitation and governor system for the first time in Korea.

The Effect of Power Sources of Department Store and Fashion Company, and Salesperson's Job Consciousness on Job Satisfaction in the Middle Management System of Department Store (백화점 중간관리 형태에서 백화점 및 패션업체의 권력원천과 판매원의 직업의식이 직무만족에 미치는 영향)

  • Lee, Hyun-Jin;Choo, Tae-Gue
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.230-241
    • /
    • 2012
  • The purpose of this study was to examine the effect of power sources of department store and fashion company, and salesperson's job consciousness on job satisfaction in the middle management system of department store. Questionnaire data from 193 salespeople in the middle management of department store were analyzed by reliability analysis, factor analysis, correlation analysis, multiple regression analysis, hierarchical regression analysis. The results of this study were as follows: First, coercive power, informational and expert power, and referent power of department store had significant effects on job satisfaction. The coercive power of department store had a negative influence on job satisfaction, while informational and expert power, and referent power of department store had a positive influence on job satisfaction. Second, referent power, expert power, reward power, coercive power of fashion company had a positive influence on job satisfaction. Third, referent power of department store had a greater influence on job satisfaction than other power sources. Fourth, job commitment and pride, prospect awareness had a positive influence on job satisfaction, while professional self-awareness had no effect on job satisfaction.

The Load Leveling Effect of Light Control System (조명제어시스템의 부하관리 효과)

  • Han, Seung-Ho;Kim, Seong-Cheol;Choi, Kyoung-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.285-287
    • /
    • 2008
  • This paper represents the electric power load leveling effect of the Light Control System(LCS). The lighting of typical mid-large commercial buildings is the major factor of daytime electric power consumption. Since the national peak power demand occurs in between 11:00 and 16:00, the dimming control of light can contribute the decrease of the power demand We will discuss the load leveling effect of dimming control with LCS.

  • PDF

DFT-based Power System Frequency Estimation using Two Digital Filters for Noise Effect Reduction (잡음영향의 저감을 위한 두 디지털 필터들의 사용에 의한 DFT 기반의 계통주파수 추정)

  • Hwang, Jin Kwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.891-897
    • /
    • 2013
  • The power system frequency plays an important role in monitoring and controlling the power system. The frequency can be measured through discrete Fourier transform (DFT) coefficients of its positive fundamental frequency. The accuracy of the frequency estimate is severely affected by noise in the power system signal and the leakage effect of the negative fundamental frequency in DFT. This paper proposes a DFT-based frequency estimation algorithm to cope with the noise as well as the leakage effect. In this algorithm, two suitable digital filters are introduced to reduce efficiently frequency estimate error due to the noise. These filters are designed to use a digital bandpass filter and a second-degree integrator. The effectiveness of the proposed algorithm in reduction of frequency estimate error is verified through simulations on noise, harmonics and frequency deviation.

Look-up Table type Digital Pre-distorter for Linearization Power Amplifier with Non-linearity and Memory Effect (전력증폭기의 비선형 특성과 Memory Effect를 보상하기 위한 Look-up Table 방식의 Digital Pre-distorter)

  • Choi, Hong-Min;Kim, Wang-Rae;Lyu, Jae-Woo;Ahn, Kwang-Eun
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.218-222
    • /
    • 2008
  • RF power amplifier requires linearization in order to reduce adjacent channel interference. And most of the existing linearization algorithms assume that a PA has memory-less nonlinearity. But for the wider bandwidth signal, the memory effect of PA cannot be ignored. This paper investigates digital pre-distortion by use of a memory polynomial model which compensates for amplifier nonlinearity and memory effect. The look-up table based implementation scheme is used to reduce the computational complexity of the pre-distortion block. The linearization performance is demonstrated on wideband CDMA signal and class AB high power amplifier.

  • PDF

MEAC Method for Analysis of Power System Stability Improving Effect Considering Run-up SPS Function of HVDC (MEAC를 적용한 HVDC Run-up SPS의 안정도향상 효과분석)

  • Lee, Jae-Gul;Song, Ji-Young;Jang, Gil-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1454-1459
    • /
    • 2017
  • In spite of continuous increase of electric power demand and new generation plants, it is very difficult to install new transmission line. Therefore, it comes to be difficult to operate the power system stable, so it is required to find another way to get new transmission capacity. Because HVDC transmission system installation is the one of the best option for us, we have undertake the HVDC project in mainland. Buckdangjin-Goduck HVDC project(500kV, 3GW) is currently under construction and Eastern Power HVDC project(500kV, 8GW) is under the study for technical specification. Both of them have the Run-up SPS function for taking action of 765kV Transmission line fault. The Run-up SPS function increases the active power output of the HVDC rapidly when the transmission line between the power plant and network is tripped, thereby preventing the generator from overspeed and improving the power system stability. In this paper, we propose MEAC(Modified Equal Area Criteria) method based on traditional EAC method to quantitatively evaluate the effect of the HVDC run-up SPS function on the power system stability improvement.

An Assessment on Voltage and Power Quality in Load Facility during the Islanding of Residential Fuel Cell System (가정용 연료전지 시스템의 단독운전 시 부하설비의 전압 및 전력품질 평가)

  • Park, Chan-Eom;Jung, Jin-Soo;Han, Woon-Ki;Lim, Hyun-Sung;Song, Young-Sang;Kim, Choon-Sam;Lim, Duk-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1792-1797
    • /
    • 2013
  • Recently, due to the excessive use of fossil fuels, many studies about the fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be reason of power quality in the power system. In this paper, we constructed the system for an assessment on Islanding. The system is composed with power source, Impedance coordination load and linear load, fuel cell system. we are performed assessment on voltage and power quality in customer and the distributed power system during the Islanding of residential fuel cell system. In addition, no change in the impedance of power system, we made a islanding condition only using the actual load, As a variation of generation and load current under islanding, an analysis results based on assessment system showed that the power qualities of distribution system became more aggravation as effect of voltage sag and voltage swell phenomena.

A Study on the Application of SFCL on 22.9 kV Bus Tie for Parallel Operation of Power Main Transformers in a Power Distribution System (배전계통에 전력용 변압기 병렬운전시 22.9 kV SFCL Bus Tie 적용방안에 관한 연구)

  • On, Min-Gwi;Kim, Myoung-Hoo;Kim, Jin-Seok;You, Il-Kyoung;Lim, Sung-Hun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • This paper analyzed the application of Superconducting Fault Current Limiter (SFCL) on 22.9 [kV] bus tie in a power distribution system. Commonly, the parallel operations of power main transformers offer a lot of merits. However, when a fault occurs in the parallel operation of power main transformer, the fault currents might exceed the interruption capacity of existing protective devices. To resolve this problem, thus, the SFCL has been studied as the fascinating device. In case that, Particularly, the SFCL could be installed to parallel operation of various power main transformers in power distribution system of the Korea Electric Power Corporation (KEPCO) on 22.9 [kV] bus tie, the effect of the resistance of SFCL could reduce the increased fault currents and meet the interruption capacity of existing protective devices by them. Therefore, we analyzed the effect of application and proposed the proper impedance of the R-type SFCL on 22.9 [kV] bus tie in a power distribution system using PSCAD/EMTDC.