• 제목/요약/키워드: Power System Effect

검색결과 3,475건 처리시간 0.031초

Study on the Heat and Mass Transfer Characteristics of Oyster Shell Flowing through the Bundle of Heating Pipes (가열원관군 주위를 유동하는 굴패각의 탈착과정에 대한 열 및 물질전달에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Power System Engineering
    • /
    • 제17권3호
    • /
    • pp.28-34
    • /
    • 2013
  • This study is experimentally performed for using the oyster shell as a desiccant in the fluidized bed with bundle of heating pipe. The test material is oyster shell from fishery wastes which can use without costs. The main parameters of experiment are inlet air temperature, velocity of inlet air and heat flux of heating pipes. Also the geometry of heating pipe is treated as important parameter. From this study, the effect of inlet air temperature and input heat flux have much affect to increase the heat and mass transfer. On the other hand, the effect of inlet air velocity has less affect to increase the heat and mass transfer. And it is clarified that the oyster shell has sufficient probability for using as a desiccant in air-conditioning system.

The Design of Power Amplifier using Temperature Memory Effect Compensation (열잡음 메모리 효과 제거기를 이용한 전력증폭기의 효율 개선)

  • Ko, Young-Eun;Lee, Ji-Young
    • The Journal of Information Technology
    • /
    • 제10권3호
    • /
    • pp.47-58
    • /
    • 2007
  • In this paper, we designed and manufactured the distortion-cancellation module which is able to compensate thermal-noise distortion by software. The distortion-cancellation algorithm not only bring forth system non-linear distortion by input level but also bring compensate component of distortion by thermal to get rid off distortion from now on. After TMS 320C6711 DSP to recognize our algorithm, we manufactured the module for every kinds of system. To evaluate efficiency of the distortion-cancellation module, we designed and manufactured communication system. By measured result, if system output power is -3dBm equally, 12dB of ACLR has improved in 1MHz away from a center frequency, and also gain has increased up to 0.5dB.

  • PDF

Study on the Adsorption and Desorption Enhance Effect of Oyster Shell Using Peltier Element (페르체소자를 이용한 굴패각의 흡착 및 탈착촉진효과에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Power System Engineering
    • /
    • 제17권1호
    • /
    • pp.71-76
    • /
    • 2013
  • This study is experimentally performed for using the oyster shell as a desiccant in the batch type system. The peltier element(thermoelectric device) is used for absorbing and releasing the adsorption and desorption heat generation. The cooling and heating effects of peltier element exist in this experiment and these effects are generally known phenomena among some references. The increase in electric current induced into peltier element is effectively release the heat generation of adsorption and desorption. Consequently, the non-dimensional adsorption and desorption amount would increase with increase in electric current. However, in the case of adsorption, the increase of induced current into peltier element, the heat of cold side can not release sufficiently. So the heat of hot side of peltier is transferred into the cold side.

Analysis of Dynamic Behavior of a Heat Recovery Steam Generator and Steam Turbine System (열회수 증기발생기와 증기터빈 시스템의 동적 거동 해석)

  • Park, Hyung-Joon;Kim, Tong-Seop;Ro, Sung-Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제24권7호
    • /
    • pp.994-1001
    • /
    • 2000
  • The dynamic behavior of a single-pressure heat recovery steam generator and turbine system for the combined cycle power plant is simulated on the basis of one-dimensional unsteady governing equations. A water level control and a turbine power control are also included in the calculation routine. Transient response of the system to the variation of gas turbine exit condition is simulated and effect of the turbine power control on the system response is examined. In addition, the effect of the treatment of inertia terms(fluid inertia and thermal inertia of heat exchanger metal) on the simulated transient response is investigated.

The Effect of Remodeling Replacement of Photovoltaic Power Generation System in Fish Farm : Analysis of Energy Saving Effect through Simulation (수조식 양식장의 태양광발전시스템 리모델링 교체 효과: 시뮬레이션을 통한 에너지절감효과 분석)

  • Choi, Hyunseok;Na, Jonghyuk;Lee, Hyunyoung;Noh, Jayeop
    • Current Photovoltaic Research
    • /
    • 제9권1호
    • /
    • pp.11-16
    • /
    • 2021
  • In the past, marine pollution caused by radioactivity and wastewater discharge caused mass destruction. As an alternative, the land farming system became common and operational. In recent years, safety and environmental problems caused by declining population due to aging of fishermen and underdeveloped facilities have always been lurking, so improvement is urgently needed. As part of the new renewable energy 3020 plan announced by the government in 2017, a new model was proposed to improve the environment as well as save energy when the roof of a water tank farm was remodeled into a solar power system. Study, when the existing roof was remodeled and replaced with a water tank farm in Busan as an empirical model, the energy saving rate was analyzed by comparing the actual electricity consumption and power generation.

Power System Analysis Model for C.C Facility of Steel Plant (제철소 연주 전기설비 설계의 모델화)

  • Cho, Yang-Haeng;Son, Jae-Hyun;Park, Kyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.362-364
    • /
    • 2001
  • Every engineering discipline has, in recent year, felt the impact of computer-aided analysis and design Normally the studies of power system analysis by computer are load flow, short circuit and harmonic calculation, the amount the voltage deviates from motor starting, reliability and system stability. These studies are very important from the operating and planning points of power system. This paper presents analysis of load flow, short circuit current calculation, the effect for voltage deviation of induction motor starting and harmonic distortion in power system of continuous casting(C. C) plant. The resulting of analysis is applied the configuration and design engineering of power system.

  • PDF

Extremely high efficiency wireless power transfer system for EV charger (전기자동차 충전을 위한 고효율 무선전력전송 시스템)

  • Moon, SangCheol;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.155-156
    • /
    • 2015
  • This paper proposes a high efficiency wireless power transfer system with an asymmetric 4-coil resonator. It presents a theoretical analysis, an optimal design method, and experimental results. In the proposed asymmetric 4-coil system, the primary side consists of a source coil and two transmitter coils which are called intermediate coils, and in the secondary side, a load coil serves as a receiver coil. In the primary side, two intermediate coils boost the apparent coupling coefficient at around the operating frequency. Because of this double boosting effect, the system with an asymmetric 4-coil resonator has a higher efficiency than the conventional symmetric 4-coil system. The prototype operates at 90 kHz ofswitching frequency and has 200 mm of the power transmission distance between the primary side and the secondary side. An AC-DC overall system efficiency of 96.56% has been achieved at 3.3 kW of output power.

  • PDF

Operating Vibration Reduction Effect Evaluation of EDG at the NPP Site (원자력발전소 비상디젤발전기의 가동중 진동저감 효과)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.111-118
    • /
    • 2006
  • The Emergency Diesel Generator(EDG) is a very important piece of equipment for the safety of a Nuclear Power Plant(NPP). In this study, the operating vibration or three kinds or EDG system was measured. The target EDG systems art Yonggwang 5 unit, Ulchin 2 unit and Ulchin 3 unit. The Yonggwang 5 and Ulchin 3 unit EDG system is the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of this measurement is for a verification of the vibration isolation effect according to the foundation system. As a result. it can he said that the spring and viscous damper system of the EDG performed well for the vibration isolation.

  • PDF

A Study on an infuence of power quality problem on the electric train at dead section (절연구간에서의 전력품질 문제가 전기철도에 미치는 영향에 관한 연구)

  • Lee, Bong-Yi;Kim, Jae-Chul;Moon, Jong-Fil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.92-94
    • /
    • 2005
  • In this paper, when electric train is in dead-section the effect on electric train system was dealt. The feeding system of electrical railway is AC or DC. When the electric train is passed AC feeding system to DC, vice versa or phase is changed in between AC feeding systems, there is a dead section. A dead section usually makes the electrical system complex md may have an adverse effect on the electrical system inside the train. Accordingly, it is important to analyze the effect on trains in dead-section. Modeling an electric train and simulation using PSCAD/EMTDC was accomplished to analyze how power quality problem such as inverter switching surge is propagated to electric train through the feeding line, railway, pantograph.

  • PDF

The Vector Control of SLIM Considering End-effect (단부효과를 고려한 편측형 선형유도전동기 벡터제어)

  • 조금배;임홍우;장용해;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.395-403
    • /
    • 2002
  • The advanced space vector PWM is Implemented for the control system using high arithmetic performance microprocessor such as DSP. It is difficult to realize the complicate SLIM which is applied to SVPWM system, but widely used in vector control system or servo control system for AC motor because of its high performance in current control. In this paper, we use the dynamic characteristic analyzing method that can calculate efficiently the end effect by using equivalent circuit methode in the operating SLIM system modeling and examine the dynamic characteristics of SVPWM with PI controller.