• Title/Summary/Keyword: Power Spectra1 Density Function

검색결과 7건 처리시간 0.067초

수평 응축관내 2상유동양식의 판별에 관한 연구 (Identification of Two-phase Flow Patterns in a Horizontal Tubular Condenser)

  • 이상천;한용운;신현승;이형돈
    • 설비공학논문집
    • /
    • 제5권1호
    • /
    • pp.65-72
    • /
    • 1993
  • An experiment has been carried out to identify flow patterns in a horizontal condensing flow with R-113. Characteristics of flow patterns were determined based upon a statistical analysis of differential pressure fluctuations at an orifice. The probability density function and power spectral density function of instantaneous pressure drop curves for various flow conditions were obtained. In comparison to the results of air-water flows, the flow patterns in a condensing flow such as annular, wavy, slug and plug could be identified. The experimental data determined by this technique were compared with the flow pattern maps suggested by other investigators. The result indicates that the statistical characteristics of differential pressure fluctuations at an orifice may be a useful tool for identifying flow patterns both in condensing flows and in adiabatic two-phase flows.

  • PDF

1/f Noise Characteristics of Sub-100 nm MOS Transistors

  • Lee, Jeong-Hyun;Kim, Sang-Yun;Cho, Il-Hyun;Hwang, Sung-Bo;Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권1호
    • /
    • pp.38-42
    • /
    • 2006
  • We report 1/f noise PSD(Power Spectrum Density) of sub-100 nm MOSFETs as a function of various parameters such as HCS (Hot Carrier Stress), bias condition, temperature, device size and types of MOSFETs. The noise spectra of sub-100 nm devices showed Lorentzian-like noise spectra. We could check roughly the position of a dominant noise source by changing $V_{DS}$. With increasing measurement temperature, the 1/f noise PSD of 50 nm PMOS device decreases, but there is no decrease in the noise of NMOS device. RTN (Random Telegraph Noise) was measured from the device that shows clearly a Lorentzian-like noise spectrum in 1/f noise spectrum.

Stochastic response spectra for an actively-controlled structure

  • Mochio, Takashi
    • Structural Engineering and Mechanics
    • /
    • 제32권1호
    • /
    • pp.179-191
    • /
    • 2009
  • A stochastic response spectrum method is proposed for simple evaluation of the structural response of an actively controlled aseismic structure. The response spectrum is constructed assuming a linear structure with an active mass damper (AMD) system, and an earthquake wave model given by the product of a non-stationary envelope function and a stationary Gaussian random process with Kanai-Tajimi power spectral density. The control design is executed using a linear quadratic Gaussian control strategy for an enlarged state space system, and the response amplification factor is given by the combination of the obtained statistical response values and extreme value theory. The response spectrum thus produced can be used for simple dynamical analyses. The response factors obtained by this method for a multi-degree-of-freedom structure are shown to be comparable with those determined by numerical simulations, demonstrating the validity and utility of the proposed technique as a simple design tool. This method is expected to be useful for engineers in the initial design stage for structures with active aseismic control.

고진등수 영역이 보강된 APR1400 설계지반응답스펙트럼의 개발 (Development of the DGRS enriched in the high frequency range for APR1400)

  • 장영선;김태영;주광호;김종학
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.67-74
    • /
    • 2001
  • This paper presents the Safe Shutdown Earthquake(SSE) input motion for the seismic design of the Advanced Power Reactor 1400(APR1400). The Design Ground Response Spectra(DGRS) far the SSE is based on the design spectrum specified in regulatory Guide(RG) 1.60 of U.S. Nuclear Regulatory Commission(US NRC), anchored to a Peak Ground Acceleration(PGA) of 0.3g and enriched in the high frequency range. This SSE seismic input motion is to be applied to the seismic analysis as the free-field seismic motion at the ground surface of both the rock and generic soil sites fur APRI1400. The enrichment for APR1400 seismic input motion is performed considering the current US NRC regulations, the seismic hazard studies performed by the Lawrence Livermore National Laboratory (LINL) and Electric Power Research Institute(EPRI) for the Central and Eastern United States nuclear power plant sites, and the seismic input motions used in the design certifications of the three existing U.S. advanced standard plants. It is represented by a set of DGRS and the accompanying Target Power Spectral Density(PSD) Function in both the horizontal and vertical directions.

  • PDF

레이저 유도 플라즈마에 대한 자기장 감금의 영향 연구 (Research on the magnetic confinement of laser-induced plasma)

  • 현은주;김용현
    • 전기전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.38-45
    • /
    • 2024
  • 간단한 자기장 감금이 레이저 유도 플라즈마의 전하 입자들에 미치는 영향이 논의 되었다. 자기장 영향에 대한 이전 연구들은 주로 플라즈마 방전 세기의 향상이나 수명시간 연장에 집중되었다. 이와 대조적으로, 본 개발은 과거에 거의 다뤄지지 않았던, 플라즈마 소멸에 대해 연구하였다. 이는 플라즈마를 활용한 기술개발에 혁신적인 도움이 될 것으로 기대한다. Nd:YAG 레이저(1064 nm, 6 ns)가 3가지 타입의 금속 물질(Al, Ti, STS)과 공기 중에 집광되었다. Nd2Fe14B 자석으로 0.4T 크기의 자기장을 만들었고, 이를 레이저 유도 플라즈마에 관통시켰다. 플라즈마 스펙트럼은 레이저 파워와 분광기의 딜레이 타임을 조정해 가면서 자기장 여부에 따른 수치가 측정되었다. O I(777.42 nm), Fe I (520.447 nm), Ti I (503.649 nm), Al I (396.147 nm) 스펙트럼 분석을 통해 자기장에 의한 플라즈마의 소멸이 특정 조건에 상관없이 항상 촉진됨을 독점적으로 발견하였다.

2채널 뇌기능 감시 시스템을 위한 뇌파 소프트웨어의 개발 (Development of an EEG Software for Two-Channel Cerebral Function Monitoring System)

  • 김동준;유선국;김선호
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.81-90
    • /
    • 1999
  • 본 연구에서는 수술이나 환자 모니터링시 무의식 상태 환자의 뇌혈류량에 대한 정확한 모니터링으로 뇌허혈 현상을 방지하기 위하여 2채널 양극성 아날로그 EEG를 디지털로 처리하여 다양한 뇌파 관련 파라미터를 추출하여 실시간으로 한 화면에 디스플레이하고, 또한 임상의사들이 사용하기 편리한 뇌파 감시 소프트웨어를 개발하고자 하였다. 이를 위하여 EEG-데이터를 FFT 연산 후 CSA 및 DSA의 형태로 표현하며, 기타 다양한 뇌파관련 파라미터를 추출한 후 한 화면에서 실시간으로 디스플레이하고, 사용 편리성도 극대화하도록 프로그램하였다. 프로그램은 개발 도중에 여러 번의 동물실험 및 임상실험을 통하여 개선 보완되었으며, EEG, CSA, DSA 및 알파비, 퍼센트 델타 스펙트럼 모서리 주파수, 전체 파워, 전체 파워의 차 등의 주요 뇌파 파라미터들을 한 화면에서 관찰하게 되어 환자 상태의 종합적인 간찰이 가능하며, 나중에 저장된 EEG 파일을 재검토할 수 있다. 또한 CSA, DSA, 스펙트럼 모서리 주파수 및 전체 파워는 원하는 부분에서 표본을 취해 화면 위쪽에 최대 3개까지 붙여 놓고 동시에 비교할 수 있으므로 환자 상태의 객관적인 비교가 가능하고, 환자상태, 응급처치 등에 대한 기록사항을 입력할 수 있어서 저장된 EEG 파일의 검토시 이들 event로 즉시 찾아가는 기능이 있으며, 그 외에도 앞 뒤 점프 이동 기능, 이득 조절 기능, 윈도우 환경에서의 파일관리 기능 등을 갖추고 있고, 프로그램이 윈도우 환경에서 개발되어 마우스에 의해 대부분의 동작이 이루어진다. 개발된 프로그램을 이용한 대학병원의 임상실험결과, 환자상태의 변화에 매우 민감하게 반응하고, 또한 임상의사들이 이용하기에도 매우 편리하다는 평가를 받았다.

  • PDF

정공 저지층의 재료변화에 따른 청색유기발광소자의 특성분석 (Analysis of Characteristics of the Blue OLEDs with Changing HBL Materials)

  • 김중연;강명구;오환술
    • 전자공학회논문지 IE
    • /
    • 제43권4호
    • /
    • pp.1-7
    • /
    • 2006
  • 본 연구에서는 정공 저지층이 없는 Type I과 정공 저지층으로 두께가 30${\AA}$인 BCP와 BAlq 재료를 사용한 Type II의 청색 유기발광소자를 제작하였다. ITO 박막 위에 $N_2$ 가스에서 플라즈마 출력이 200 W 일 때, 5.02 eV의 일함수 값을 갖는 ITO를 얻을 수 있었다. Type I 소자는 ITO/2-TNATA/$\alpha$-NPD/DPVBi/$Alq_3$/LiF/Al:Li 구조로 되어 있으며, Type II 소자는 ITO/2-TNATA/$\alpha$-NPD/DPVBi/정공 저지층/$Alq_3$/LiF/Al:Li 구조로 되어 있다. Type I과 Type II 소자의 특성을 비교하였다 제작된 소자 중에서 특성이 가장 우수한 것은 정공 저지층으로 두께가 30${\AA}$인 BAlq 재료를 사용한 Type II 소자이었고, 인가전압 10 V 에서 소자의 전류밀도는 226.75$mA/cm^2$, 휘도는 10,310$cd/cm^2$, 발광효율은 4.55 cd/A, 전력효율은 1.43 lm/W 이었다. EL 스펙트럼의 최대 발광 파장은 456 nm 반치폭은 57 nm 이었고 색좌표값은 x = 0.1438, y = 0.1580 로 NTSC 색좌표 Deep blue영역(x = 014, y = 0.08)에 근접한 순수한 청색에 가까운 값을 얻었다.