• 제목/요약/키워드: Power Series Method

검색결과 843건 처리시간 0.027초

Phase Shift Control for Series Active Voltage Quality Regulators

  • Xiao, Guochun;Teng, Guofei;Chen, Beihai;Zhang, Jixu
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.664-676
    • /
    • 2012
  • A phase shift algorithm based on the closed-loop control of dc-link voltage implemented on a series active voltage quality regulator (AVQR) is proposed in this paper. To avoid pumping-up the dc-link voltage, a general phase shift compensation strategy is applied. The relationships among the operation variables are discussed in detail, which is very important for guiding the design of both the main circuit and the control system. Then on the basis of an investigation of the dc-link voltage pumping-up from viewpoint of the active power flow, a novel phase shift control method based on the closed-loop of the dc-link voltage is proposed. This method can adjust the phase of the output voltage gradually and automatically according to the dc-link voltage variation without introducing a phase jump. The effectiveness of the proposed strategy is verified through simulations of a single-phase 5kVA prototype and laboratory experiments on both a single-phase 5kVA and a three-phase 15kVA prototype.

전력 시스템의 동요 억제를 위한 TCSC용 안정화 장치 설계 (A Design of Power System Stabilization of TCSC System for Power system Oscillation Damping)

  • 정형환;허동렬;왕용필;박희철;이동철
    • 조명전기설비학회논문지
    • /
    • 제16권2호
    • /
    • pp.104-112
    • /
    • 2002
  • 본 논문에서는 FACTS 기기의 일종인 전력조류 극대화 및 제어 기능과 함께 외란에 의한 과도시의 전력계통 안정화 기능을 수행할 수 있는 TCSC용 전력시스템 안정화 장치 설계에 대하여 연구하였다. TCSC용 전력시스템 안정화 장치 설계시 파라미터 선정은 복잡한 수식이 필요 없고 계산시간을 감소시키며 적은 반복횟수로도 최적해를 찾을 수 있는 자연 생태계의 진화를 모의한 유전 알고리즘을 이용하였다. 전력 시스템의 저주파 진동에 강인성을 갖는 TCSC는 TCR(Thyristor Controlled Reactor)과 커패시터의 병렬구조에 의해 용량성과 유도성에 걸친 범위가지 연속적으로 제어할 수 있는 구조로 이루어져 있다. 이러한 제안된 방법의 강인성을 검증하기 위해 여러 가지 운전조건에 대해 전력계통 안정도 및 고유치를 해석하여 기존의 안정화 장치를 적용한 경우와 비교함 으로써 유용성을 입증하였다.

다중 출력 LLC 직렬 공진 컨버터의 이득 특성 연구 (A Study on the Gain Characteristics of Multi-output LLC Series Resonant Converter)

  • 이재삼;박준호;허동영;강성인;김주훈;김은수
    • 전력전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.177-187
    • /
    • 2009
  • 본 논문에서는 다중 출력을 갖는 LLC 직렬 공진 컨버터의 입출력 이득에 대한 새로운 해석법을 제시한다. 특히 Math-CAD 시뮬레이션을 통해 변압기 2차 측 누설인덕턴스 성분에 의한 주파수 이득특성 변화를 분석한다. 유도된 수식 이론을 근거로, 3개의 출력을 갖는 430W급 공진 컨버터를 제작하여 46인치용 PDP 파워모듈의 Sustain 블록에 적용함으로서, 제안된 해석법의 정확성을 검증한다.

Chaos를 이용한 단기부하예측 (A Daily Maximum Load Forecasting System Using Chaotic Time Series)

  • 최재균;박종근;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.578-580
    • /
    • 1995
  • In this paper, a method for the daily maximum load forecasting which uses a chaotic time series in power system and artificial neural network. We find the characteristics of chaos in power load curve and then determine a optimal embedding dimension and delay time, For the load forecast of one day ahead daily maximum power, we use the time series load data obtained in previous year. By using of embedding dimension and delay time, we construct a strange attractor in pseudo phase plane and the artificial neural network model trained with the attractor font mentioned above. The one day ahead forecast errors are about 1.4% of absolute percentage average error.

  • PDF

Chaos특성을 이용한 단기부하예측 (A short-term Load Forecasting Using Chaotic Time Series)

  • 최재균;박종근;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.835-837
    • /
    • 1996
  • In this paper, a method for the daily maximum load forecasting which uses a chaotic time series in power system and artificial neural network(Back-propagation) is proposed. We find the characteristics of chaos in power load curve and then determine a optimal embedding dimension and delay time. For the load forecast of one day ahead daily maximum power, we use the time series load data obtained in previous year. By using of embedding dimension and delay time, we construct a strange attractor in pseudo phase plane and the artificial neural network model trained with the attractor mentioned above. The one day ahead forecast errors are about 1.4% for absolute percentage average error.

  • PDF

Reliability Calculation of Power Generation Systems Using Generalized Expansion

  • Kim, Jin-O
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.123-130
    • /
    • 1997
  • This paper presents a generalized expansion method for calculating reliability index in power generation systems. This generalized expansion with a gamma distribution is a very useful tool for the approximation of capacity outage probability distribution of generation system. The well-known Gram-Charlier expansion and Legendre series are also studied in this paper to be compared with this generalized expansion using a sample system IEEE-RTS(Reliability Test System). The results show that the generalized expansion with a composite of gamma distributions is more accurate and stable than Gram-Charlier expansion and Legendre series as addition of the terms to be expanded.

  • PDF

태양광 PV 어레이에서 병렬 부정합을 저감시키는 모듈 부정합 보상기법 (Method for PV Module Mismatch Compensation to Reduce Parallel Mismatch in Solar PV Array)

  • 박기엽;안희욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.170-171
    • /
    • 2010
  • The power loss due to PV module mismatch in PV array system is analyzed and a mismatch compensation method is proposed. A dc-dc converter is used to compensate for series mismatch caused by a low current module in a string. The converter is controlled to maximize the array power output. The proposed compensation method was verified by PSpice simulation.

  • PDF

인덕터 내부저항을 고려한 LCL 필터의 능동댐핑 특성 (Active Damping Characteristics on Virtual Series Resistances of LCL Filter for Three-phase Grid-connected Inverter)

  • 김용중;김효성
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.88-93
    • /
    • 2016
  • LCL filters are widely used in high-order harmonics attenuation of output currents in grid-connected inverters. However, output currents of grid-connected inverters with LCL filters can become unstable because of the resonance of the filters. Given that the characteristics of output currents in inverters mostly depend on filter performance, the exact analysis of filters by considering parasitic components is necessary for both harmonics attenuation and current control. LCL filters have three or four parasitic components: the series and/or parallel resistance of the filter capacitor and the series resistance of the two filter inductors. Most studies on LCL filters have focused on the parasitic components of the filter capacitor. Although several studies have addressed the parasitic components of the filter inductor at the inverter side, no study has yet investigated the concurrent effects of series resistance in both filter inductors in detail. This paper analyzes LCL filters by considering series resistance in both filter inductors; it proposes an active damping method based on the virtual series resistance of LCL filters. The performance of the proposed active damping is then verified through both simulation and experiment using Hardware-in-the-Loop Simulator(HILS).

Short-circuit Protection for the Series-Connected Switches in High Voltage Applications

  • Tu Vo, Nguyen Qui;Choi, Hyun-Chul;Lee, Chang-Hee
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1298-1305
    • /
    • 2016
  • This paper presents the development of a short-circuit protection mechanism on a high voltage switch (HVS) board which is built by a series connection of semiconductor switches. The HVS board is able to quickly detect and limit the peak fault current before the signal board triggers off a gate signal. Voltage clamping techniques are used to safely turn off the short-circuit current and to prevent overvoltage of the series-connected switches. The selection method of the main devices and the development of the HVS board are described in detail. Experimental results have demonstrated that the HVS board is capable of withstanding a short-circuit current at a rated voltage of 10kV without a di/dt slowing down inductor. The corresponding short-circuit current is restricted to 125 A within 100 ns and can safely turn off within 120 ns.

Static Synchronous Series Compensator(SSSC) 댐핑 제어 및 해석모형 (Damping Control Strategy and Analysis Model of Static Synchronous Series Compensator(SSSC))

  • 김학만;전영환;오태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.509-515
    • /
    • 2000
  • This paper addresses a damping control strategy of Static Synchronous Series Compensator(SSSC) and analysis model for stability study. The effect of injected voltage source generated by SSSC is modelled as equivalent load. This model is thought to be reasonable for the stability study because the dynamics of SSSC is very fast compared with that of power system. Damping controller of SSSC is based on Transient Energy Function method. The proposed control strategy is insensitive to the operating conditions like power flow level because control law depends on the phase angles. The proposed analysis model and control strategy was confirmed by WSCC 9 bus system and two area system. Especially, the robustness of proposed control strategy is demonstrated with respect to multiple operating conditions in two area system.

  • PDF