• Title/Summary/Keyword: Power Quality Cost

Search Result 434, Processing Time 0.026 seconds

Power Quality Disturance Generator with Phase Jump Function (위상 급변 기능이 있는 전력품질 외란 발생기)

  • Lee B.C.;Choi S.H.;Paeng S.H.;Nho E.C.;Kim I.D.;Chun T.W.;Kim H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.96-100
    • /
    • 2004
  • This paper deals with power quality disturbance generator with phase jump function. The proposed generator can be applied to the performance test of custom power devices. Voltage sag, swell, outage, unbalance and phase jump after outage are provided by the generator. The phase jump operating principle of the generator is described and analysed. The control scheme of the disturbance generator is simple and hardware setup is cost effective compared with the conventional scheme. The usefulness of the generator is verified through simulation and experimental results.

  • PDF

Design of Robust GA-QFT Controller for Enhancement of Power System Stability (전력계통의 안정도 향상을 위한 강인한 GA-QFT 제어기 설계)

  • Chung, Hyeong-Hwan;Lee, Jeong-Phil;Hur, Dong-Ryol;Kim, Chang-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.4
    • /
    • pp.197-207
    • /
    • 2001
  • In this paper, design problem of QFT-PSS using Genetic Algorithm(GA) is investigated for power systems with parameter variation and disturbance uncertainties. A robust controller for uncertain power systems can be designed automatically such that the cost of feedback is minimized and all robust stability and performance specifications are satisfied. It is shown that the proposed design method not only automates loop shaping but also improves design quality and improves the quality with a reduced order controller. The robustness of the proposed controller has been investigated on a single machine infinite bus model. The results are shown that the proposed QFT-PSS using GA is more robust tan conventional PSS.

  • PDF

Power Quality Improvement of an Electric Arc Furnace Using a New Universal Compensating System

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein;Ali Yazdian-Varjani
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.195-204
    • /
    • 2006
  • This paper presents a new compensating system, consisting of series and shunt active filters, for mitigating voltage and current disturbances. The shunt filter is used to compensate for unbalanced and distorted load currents. The series filter comprises two inverters, used to suppress voltage disturbances and handle source currents independently. This configuration is devised to reduce the overall cost of active compensators by using low-frequency high-current switches for the latter inverter. The filters are controlled separately using a novel control strategy. Since voltages at the point of common coupling contain interharmonics, conventional methods cannot be used for extracting voltage references. Therefore, voltage references are obtained from generated sinusoidal waveforms by a phase-locked loop. Current references are detected based on rotating frame vector mapping. Simulation results are presented to verify the system.

Power Quality Measurement for LED-based Green Energy Lighting Systems (LED 기반 그린에너지 조명시스템을 위한 전력품질 측정)

  • Yu, Hyung-Mo;Choi, Jin-Won;Choe, Sangho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.174-184
    • /
    • 2013
  • For the successful R&D and deployment of LED-based green energy lighting systems, the real-time power quality measurement of both various non-linear power signals including pulse waveform, spike waveform, etc and the undesired-signals including harmonics, sag, swell, etc is required. In this paper, we propose a low-cost power quality measurement (PQM) method for low- (60Hz-several KHz) to high-frequency (several tens KHz) power signals, which are generated by green-energy lighting systems, and implement a PQM testbed using TI TMS320F28335 MCU. The proposed algorithm is programmed using C in the CCS (Code Composer Studio) 3.3 environment and is verified using test signals generated by an arbitrary signal generator, NF-WF1974. In the implemented testbed, we can measure various non-linear current signals that LED SMPS generates, analyze harmonics by fast Fourier transform, and test sag, swell, and interruption using wavelet transform.

Low-Cost High-Efficiency PDP Sustaining Driver with a Resonance Bias Level Shift

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.779-786
    • /
    • 2013
  • A highly efficient sustaining driver is proposed for plasma display panels (PDPs). When the PDP is charged and discharged, the proposed sustaining driver employs an address voltage source used in an addressing period. A voltage source is used for fully charging the panel to the sustaining voltage, and an initial inductor current helps the panel discharge to 0 V. The resonance between the panel and an inductor is made by shifting the voltage and current bias level when charging and discharging the panel. As a result, the proposed circuit can reduce power consumption, switching loss, heat dissipation, and production cost. Experimental results of a 42-inch PDP are provided to verify the operation and features of the proposed circuit.

Management in the EPC Business for Overseas Power Plant Projects (해외 발전플랜트 EPC 사업의 리스크 분석 및 관리방안)

  • Park, Euiseung;Yoo, Hoseon;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.7 no.3
    • /
    • pp.48-64
    • /
    • 2011
  • In this work, risks in EPC project for overseas power plant projects are analyzed and risk management methods are suggested to reduce cost and to shorten time. 79% of risks occurred in the engineering phase for S project located in South-East Asia. The impact scales of risks on major project objectives which are cost, time, scope, and quality are analyzed as 3.5, 3.8, 2.7, and 3.7, respectively. The level of impact scales is very similar to each other except the impact scale of scope. The risk management methods suggested in this study have to be applied at the appropriate time to manage risks effectively. After that, risks are managed continuously by monitoring.

  • PDF

A Case Study on the Quality Management of Construction Site through PDCA Cycle (PDCA Cycle적용을 통한 건설현장 품질관리에 관한 사례연구)

  • Baik, In-Whee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • According to the recent trends which are the diversity of customer requests and the multi-function of buildings, A construction company's business has converted from the producer-oriented approach to the consumer-oriented approach. Therefore, each construction company is continuously trying to improve the quality level as a way of corresponding to customer needs in these changing situations. The quality is one of the main management targets which judge the success of a project along with the schedule, the cost and the safety. As construction companies execute the quality management which they aimed at, it should be completed within the optimum schedule and the limit of the budget. Accordingly, the importance of the construction site management to complete a project is continuously increasing. The construction site management is the systematic method to perform the project goals such as the quality improvement, the cost saving and the safety management, which organically operate one another, by procuring the manpower, the material and the machine in the right time. Specially, as the construction industry has based on the construction site, the establish of systematic construction site management, which can effectively correspond sudden changes of the construction business environment, is essential to maximize the construction productivity. On top of that, the necessity of the quality management method is increasing to accommodate customer needs more spontaneously in the construction site. These endeavors could guarantee their competitive power.

Development of Power Quality Measurement System for Harmonics Diagnosis of Electrical Equipment (전기설비의 고조파 진단을 위한 전력품질 측정시스템의 개발)

  • 유재근;이상익;전정채
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.130-137
    • /
    • 2003
  • Because of falling-off in power quality by harmonics, obstacles like lowering of capability, noise, vibration of power facilities and so on are occurred. Also generation of harmonics is inevitable and the point at harmonics is seriously gathering strength because energy saving installation using semiconductor circuit as countermeasures to enhance energy efficiency will be broadly spread and the use of energy conversion equipment like motor speed control contrivance, energy keeping installation and so on will increase, in the future. In order to eliminate harmonics obstacle, precision measurement and analysis on voltage, current, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion, and so forth are needed. In this paper, we developed low-cost measurement system to measure and analyze power quality connected with harmonics and verified it's performance by measuring and analyzing power quality in the three-phase and four-wire system.

Exploiting Quality Scalability in Scalable Video Coding (SVC) for Effective Power Management in Video Playback (계층적 비디오 코딩의 품질확장성을 활용한 전력 관리 기법)

  • Jeong, Hyunmi;Song, Minseok
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.11
    • /
    • pp.604-609
    • /
    • 2014
  • Decoding processes in portable media players have a high computational cost, resulting in high power consumption by the CPU. If decoding computations are reduced, the power consumed by the CPU is also be reduced, but such a choice generally results in a degradation of the video quality for the users, so it is essential to address this tradeoff. We proposed a new CPU power management scheme that can make use of the scalability property available in the H.164/SVC standard. We first proposed a new video quality model that makes use of a video quality metric(VQM) in order to efficiently take into account the different quantization factors in the SVC. We then propose a new dynamic voltage scaling(DVS) scheme that can selectively combine the previous decoding times and frame sizes in order to accurately predict the next decoding time. We then implemented a scheme on a commercial smartphone and performed a user test in order to examine how users react to the VQM difference. Real measurements show that the proposed scheme uses up to 34% fewer energy than the Linux DVFS governor, and user tests confirm that the degradation in the quality is quite tolerable.

Development of Progress Management System based on Quality Inspection Information - Case Study on Nuclear Power Plant Construction - (품질관리 정보를 기반으로 한 진척도 관리 시스템 개발 - 원자력발전소 건설공사 사례를 중심으로 -)

  • Kwahk, Kil-Jong;Kim, Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.1
    • /
    • pp.73-84
    • /
    • 2011
  • This study represents construction progress management model based on quality inspection process in addition to cost-schedule integration. Quality inspection process cycle, resource estimate as progress measurement parameter, hierarchical structure of schedule, and inspection lots linking quality inspection to resource estimate are addressed as four main information areas. The authors established several process models to give a structure and correlations among information elements on each of these areas. Applying the process models proposed, an information system was implemented and utilized for nuclear power plant construction. It reveals that the system achieves accurate and objective progress information in near real time with significantly reduced time and effort as well as administrative efficiencies from making quality inspection process online.