• Title/Summary/Keyword: Power ON/OFF

Search Result 2,099, Processing Time 0.032 seconds

Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Sang-Kil;Kim, Beom-Soo;Kim, Doo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1086-1092
    • /
    • 2015
  • The off-line and on-line partial discharge (PD) in the stator winding of three high-voltage (HV) motors (1,400 HP, 6.6 kV) is measured and analyzed in this paper. The off-line PD is measured at high values between 24,300 ~ 36,100 pC after 18 years of motor operation. Spare replacement motors were not available for testing the degree of deterioration of the stator windings in standstill status. Therefore, on-line periodic analysis was conducted to monitor the trend of PD after installing a ceramic sensor (110 pF, 6.6 kV) in the terminal box for each phase of each motor. In the stator winding of the No.1 and No.2 HV motors, which showed high magnitudes of off-line PD and low magnitudes of on-line PD, defects are expected to appear in the neutral end of the winding. On the contrary, in the stator windings of the No.3 HV motor, which exhibits high off-line and on-line PD magnitude, defects are expected to appear in the terminal end of the winding where a voltage close to the phase voltage is applied.

New ZVZCT Bidirectional DC-DC Converter Using Coupled Inductors

  • Qian, Wei;Zhang, Xi;Li, Zhe;Jin, Wenqiang;Wiedemann, Jochen
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.11-23
    • /
    • 2019
  • In this study, a novel zero voltage zero current transition (ZVZCT) bidirectional DC-DC converter is proposed by employing coupled inductors. This converter can turn the main switch on at ZVZCT and it can turn it off with zero voltage switching (ZVS) for both the boost and buck modes. These characteristics are obtained by using a simple auxiliary sub-circuit regardless of the power flow direction. In the boost mode, the auxiliary switch achieves zero current switching (ZCS) turn-on and ZVS turn off. Due to the coupling inductors, this converter can make further efficiency improvements because the resonant energy in the capacitor or inductor can be transferred to the load. The main diode operates with ZVT turn-on and ZCS turn-off in the boost mode. For the buck mode, there is a releasing circuit to conduct the currents generated by the magnetic flux leakage to the output. The auxiliary switch turns on with ZCS and it turns off with ZVT. The main diode also turns on with ZVT and turns off with ZCS. The design method and operation principles of the converter are discussed. A 500 W experimental prototype has been built and verified by experimental results.

Tail current and its effect on turn-off performance of power GTO thyristor (GTO의 턴-오프 과도전류와 과도전류가 스위칭에 미치는 영향)

  • Zhang, Chang-Il;Li, Chong;Ji, Ling-Yun;Min, Won-Gi;Kim, Sang-Cheol;Park, Jong-Mun;Kim, Eun-Dong;Kim, Nam-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.417-420
    • /
    • 1998
  • In this paper the formation mechanism of tail current is analyzed and its effect on GTO turn-off performance is given. The conclusion is that the large tail current will considerably increase the turn-off loss $E_{off}$ and cause the re-triggering during GTO's off-switching, therefore the best design criterion is that the tail current of power GTO must be as low as possible.w as possible.

  • PDF

Evaluation of 0ff-gas Characteristics in Vitrification Process of ion-Exchange Resin

  • Park, S. C.;Kim, H. S.;K. H. Yang;C. H. Yun;T. W. Hwang;S. W. Shin
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.83-92
    • /
    • 2001
  • The properties of off-gas generated from vitrification process of ion-exchange resin were characterized. Theoretical composition and flow rate of the off-gas were calculated based on chemical composition of resin and it's burning condition inside CCM. The calculated off-gas flow rate was 67.9Nm$^3$/h at the burning rate of 40kg/h. And the composition of off-gas was avaluated as $CO_2$(41.4%), steam(40.0%), $O_2$(13.3%), NO(3.6%), and SO$_2$(1.6%) in order. Then, actual flow rate and composition of off-gas were measured during pilot-scale demonstration tests and the results were compared with theoretical values. The actual flow rate of off-gas was about 1.6 times higher than theoretical one. The difference between theoretical and actual flow rates was caused by the in-leakage of air to the system, and the in-leakage rate was evaluated as 36.3Nm$^3$/h. Because of continuous change in the combustion parameters inside CCM, during demonstration tests, the concentration of toxic gases showed wide fluctuation. However, the concentration of CO, a barometer of incompleteness of combustion inside CCM, was stabilized soon. The result showed quasi-equilibrium state was achieved two hours after feeding of resin.

  • PDF

Dynamic Shutdown of Server Power Mode Control for Saving Energy in a Server Cluster Environment (서버 클러스터 환경에서 에너지 절약을 위한 서버 전원 모드 제어에서의 동적 종료)

  • Kim, Hoyeon;Ham, Chihwan;Kwak, Hukeun;Chung, Kyusik
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.7
    • /
    • pp.283-292
    • /
    • 2013
  • In order to ensure high performance, all the servers in an existing server cluster are always On regardless of number of real-time requests. They ensure QoS, but waste server power if some of them are idle. To save energy consumed by servers, the server power mode control was developed by shutdowning a server when a server is not needed. There are two types of server power mode control depending on when a server is actually turned off if the server is selected to be off: static or dynamic. In a static mode, the server power is actually turned off after a fixed time delay from the time of the server selection. In a dynamic mode, server power is actually turned off if all the services served in the server are done. This corresponds to a turn off after a variable time delay. The static mdoe has disadvantages. It takes much time to find an optimal shutdown time manually through repeated experiments. In this paper, we propose a dynamic shutdown method to overcome the disadvantages of static shutdown. The proposed method allows to guarantee user QoS with good power-saving because it automatically approaches an optimal shutdown time. We performed experiments using 30 PCs cluster. Experimental results show that the proposed dynamic shutdown method is almost same as the best static shutdown in terms of power saving, but better than the best static shutdown in terms of QoS.

Off-time Control Method for High Power Density AC/DC Adapter (고전력밀도 AC/DC Adapter를 위한 off-time 제어법)

  • Kang, Shin-Ho;Jang, Jun-Ho;Hong, Sung-Soo;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.510-516
    • /
    • 2007
  • The proposed method offers an improved control method for high power density AC/DC adapter by using more energy efficient electrical equipments. Power factor correction (PFC) topology is based on boost topology with boundary conduction mode (BCM). DC/DC topology is based on half-bridge topology with fixed 50% duty and newly introduced off-time control method, which helps to reduce size of the semiconductor and the magnetic devices. Test results with 85W AC/DC adapter (18.5V/4.6A) design show that the measured efficiency is 90% with power density of $36W/in^3$. It also shows low no load power consumption of about 0.5W.

A Study on Market Power and Compensation for Constrained Off generators under Uniform Pricing Scheme (Uniform Pricing 체계 하에서의 시장지배력과 제약비발전 보상체계)

  • Shin, Young-Gyun;Kim, Bal-Ho H.;Jun, Yeoung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.649-651
    • /
    • 2003
  • In the framework of competitive electricity market, the Market Power due to the transmission congestion, lack of demand-side response, various uncertain factors etc. have been significant problem. This paper reviews the market rules of Korea power system and the uplift scheme for constrained on/off generators. Then, this paper points out several problems and the mitigation measures of local market power concerning the compensation for constrained-off generators.

  • PDF

Design of 4.5kV/1.5kA IGCT (4.5kV/1.5kA급 IGCT 설계 및 특성분석)

  • Kim, Hyoung-Woo;Kim, Sang-Cheol;Seo, Kil-Su;Kim, Eun-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.357-360
    • /
    • 2003
  • In this paper, we designed 4.5kV/1.5kA IGCT devices. GCT thyristor has many superior characteristics compared with GTO thyristor, for examples; snubberless turn-off capability, short storage time, high turn-on capability, small turn-off gate charge and low total power loss of the application system containing device and peripheral parts such as anode reactor and snubber capacitance. In this paper we designed GCT thyristor devices, and analyzed static and dynamic characteristics of GCT thyristor depending on the minority carrier lifetime, n-base thickness and doping concentration of n-base region, respectively. Especially, turn-on and turn-off characteristics are very important characteristics for GCT thyristor devices. So, we considered above characteristic for design and analysis of GCT devices.

  • PDF

Modeling for Discovery the Cutoff Point in Standby Power and Implementation of Group Formation Algorithm (대기전력 차단시점 발견을 위한 모델링과 그룹생성 알고리즘 구현)

  • Park, Tae-Jin;Kim, Su-Do;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.1
    • /
    • pp.107-121
    • /
    • 2009
  • First reason for generation of standby power is because starting voltage must pass through from the source of electricity to IC. The second reason is due to current when IC is in operation. Purpose of this abstract is on structures of simple modules that automatically switch on or off through analysis of state on standby power and analysis of cutoff point patterns as well as application of algorithms. To achieve this, this paper is based on analysis of electric signals and modeling. Also, on/off cutoff criteria has been established for reduction of standby power. To find on/off cutoff point, that is executed algorithm of similar group and leading pattern group generation in the standby power state. Therefore, the algorithm was defined as an important parameter of the subtraction value of calculated between $1^{st}$ SCS, $2^{nd}$ SCS, and the median value of sampling coefficient per second from a wall outlet.

  • PDF

Comparison of Real Power between Continuous and ON/OFF Operation of Ballast for Fluorescent Lamps (형광등 안정기의 연속 점등과 ON/OFF시 실제 소비 전력 비교)

  • 이용후;이진우;노재엽
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.76-79
    • /
    • 1999
  • This paper describes real power difference continuous and on/off operation of ballast for fluorescent lamps. We tested ballasts for fluorescent lamps, such that glow stater ballast, rapid stating ballast, and electronic ballast. We measured consumed real power. Input voltage is A.C. 220V and ON time 8 is minutes, OFF time 2 is minutes.

  • PDF