• 제목/요약/키워드: Power Monitoring System

검색결과 1,934건 처리시간 0.031초

디지털보호계전기를 이용한 기중차단기 제어 및 모니터링 (Control And Monitoring Of Air Circuit Breaker Using Digital Protective Relay)

  • 이성환;박상배;안인석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.240-242
    • /
    • 2001
  • On this research, to catch up with international trend on the power system utilities move to be digitalized and move to network is certainly technological on the global business world, to compete with advanced foreign countries in the range of transmit and distribute power system and to take possession of first market share within country, we talked over a monitoring system to diagnose, monitor ACB(Air Circuit Breaker) only which is operated on the low level voltage Power plant. AMS(ACB Monitoring System) have be configured with several modules such as engine module which acquire engineering data from HICM360/860(Communication Control Units) and analyze and save it, database module which restore data and can be inquired, system monitoring view module which reflects fields information within a second, realtime trend window, historical trend window, reports as daily and yearly. In a near future, AMS must upgrade GUI to have easy to handle and have to have a field test to fit on real plants, so it will have faith in system reliability as it can apply power plant monitoring system in wide.

  • PDF

발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구 (A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop)

  • 김학만;박철원
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

Low-power Environmental Monitoring System for ZigBee Wireless Sensor Network

  • Alhmiedat, Tareq
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권10호
    • /
    • pp.4781-4803
    • /
    • 2017
  • Environmental monitoring systems using Wireless Sensor Networks (WSNs) face the challenge of high power consumption, due to the high levels of multi-hop data communication involved. In order to overcome the issue of fast energy depletion, a proof-of-concept implementation proves that adopting a clustering algorithm in environmental monitoring applications will significantly reduce the total power consumption for environment sensor nodes. In this paper, an energy-efficient WSN-based environmental monitoring system is proposed and implemented, using eight sensor nodes deployed over an area of $1km^2$, which took place in the city of Tabuk in Saudi Arabia. The effectiveness of the proposed environmental monitoring system has been demonstrated through adopting a number of real experimental studies.

CAN을 이용한 발전계통의 제어 및 모니터링 기법 연구 (A Study on the Power System Control and Monitoring Technique Using CAN)

  • 정준홍;최수영;박기헌
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.268-276
    • /
    • 2003
  • In this paper, we present a new control and monitoring technique for a power system using CAN(Controller Area Network). Feedback control systems having co'ntrol loops closed through a network(i.e. Ethernet, ControlNet, CAN) are called NCSs(Networked Control Systems). The major problem of NCSs is the variation of stability property according to time delay including network-induced delay and computation delay in nodes. We present a new stability analysis method of NCSs with time delay exploiting a state-space model of LTI(Linear Time Invariant) interconnected systems. The proposed method can determine a proper sampling period of NCSs that preserves stability performance even in NCSs with a dynamic controller. We design CAN nodes which can transmit control and monitoring data through CAN bus and apply these to NCSs for a power system. The results of the experiment validate effectiveness of our control and monitoring technique for a power system.

TMS320C6701 프로세서를 이용한 전력 품질 측정 (Power Quality Measurement Using TMS320C6701 Processor)

  • 신명준;손영익;김갑일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.50-52
    • /
    • 2005
  • Research interests in PQ(Power Quality) measurement and monitoring system have been increased. This paper describes an experimental result for monitoring system that monitors power quality and undesirable accidents when distributed generations are connected to the power grid. Prior to develop a physical monitoring system for distributed generation applications, we constitute a mesuring system for the general PQ factors. In this paper, an approach to how to measure the PQ elements is presented by using TMS320C6701 processor. Simulation results using the PSCAD and the power system simulation equipment Dobel have verified the proposed measurement system.

  • PDF

중대규모 계통연계형 PV시스템의 성능결과 (Performance monitoring results of large-scale PV system)

  • 소정훈;유권종;정영석;유병규;황혜미;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1165-1166
    • /
    • 2006
  • This paper presents performance monitoring results of large scale photovoltaic (PV) system supported by general dissemination & regional energy program in korea government polices for new and renewable energy resources. 80kW PV system and monitoring system is constructed and monitored PV system performance to observe the overall effect of environmental conditions on their operation characteristics. The PV system performance has been evaluated and analyzed for component perspective (PV array and power conditioning unit) and global perspective (system efficiency, capacity factor, and electrical power energy and power quality etc.) for six month monitoring periods.

  • PDF

LPMS 신호분석 연구 (A Study on the Signal Analysis of Loose Parts Monitoring System)

  • 이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.839-841
    • /
    • 2014
  • The Nuclear Steam Supply System(NSSS) is designed to provide an integrated approach that includes areas of monitoring relevant to the integrity of the NSSS. LPMS is designed to function as an alarm system by providing sensor channel alarms for the associated subsystems. LPMS is equipped to provide analysis tools for new alarm events, historical events and for historical periodically stored channel data (e.g. waveforms) for most channels. This paper is intended to introduce the diagnosis principle and abnormal symptom of loose parts monitoring system as a monitoring tool in Nuclear Steam Supply System. And also, we are going to introduce signal analysis program in order to perform the actual diagnosis in power plants.

  • PDF

배전설비의 온라인 모니터링과 진단 기술 동향 (A Technical Trend on On-Line Condition Monitoring and Diagnostics of Power Equipments)

  • 임완수;이태우;여운철;이성길;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1974-1975
    • /
    • 2007
  • Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system. The paper presents the results of wireless temperature monitoring of switchgear at a power plant over a two-year period.

  • PDF

원자력발전소의 부지감시시스템의 운영과 활용 (Site Monitoring System of Earthquake, Fault and Slope for Nuclear Power Plant Sites)

  • 박동희;조성일;이용희;최원학;이동훈;김학성
    • 자원환경지질
    • /
    • 제51권2호
    • /
    • pp.185-201
    • /
    • 2018
  • 원자력발전소는 부지선정, 부지조사, 설계, 건설 및 운영의 전 과정에 걸쳐 지질조사, 단층 및 지진 특성 분석, 탄성파 탐사, 시추조사, 지반특성 분석 등 모든 가능한 지질학적, 지진학적, 지구물리학적 조사와 자료 분석을 통하여 자연재해 및 인위적 재해에 대하여 건전성을 확보할 수 있도록 견고하게 건설, 운영되고 있다. 본 단보에서는 한국수력원자력(주)에서 자연재해에 대해 원자력발전소 부지의 안전성을 평가하기 위하여 구축하여 운영 중인 지진관측시스템, 단층감시시스템, 사면감시시스템 등 일련의 부지감시시스템의 현황 및 주요 관측 자료에 대한 분석결과를 소개하고자 한다. 원자력발전소에는 발전소의 구조물 및 자유장에 여러 대의 가속도계와 지진 트리거로 구성된 지진감시계통을 구성하여 내진설계의 적절성 평가, 지진으로 인한 운전기준 초과 판정, 지진 신속 대응에 활용하고 있다. 이와는 별도로 단층과 지진과의 상관성 분석, 지진발생 특성 연구, 지진재해도 평가 등 원전 부지의 지진안전성 확보를 위하여 1999년부터 원자력 발전소 부지 내 및 인근 지역에 총 13개소의 지진관측소를 운영하고 있으며, 2017년 최신의 지진관측 장비로 교체 설치하였다. 또한 원전 인근의 단층의 활동성을 감시하기 위하여 국내에서 처음으로 체계적으로 단층감시 기반을 확립한 읍천단층 감시시스템(Eupcheon Fault Monitoring System, EFMS)을 2012년 1월부터 운영하고 있다. EFMS는 시추공 변형률계 및 지진계, 지표변위계, GPS, 지하수위계 등으로 구성되며, 상기 계측기의 자료분석 결과 읍천단층은 한반도 동남부 일대에서 발생된 지진에 의해서도 영향을 받지 않는 안정된 단층임을 입증할 수 있었으며, 단층의 지진 안전성 해석과 지진예측 연구에도 단층 감시시스템이 매우 유용하게 활용될 수 있음을 확인하였다. 추가적으로, 2016년부터는 원전 부지 내 사면의 안전성 평가를 위하여 한울원전 배후사면을 대상으로 지중경사계, 지표경사계, 사면변위계, 강우량계 등을 설치하고 K-SLOPE 시스템을 구축하여 사면 거동을 감시하고 있으며, 전체 사면의 거시적 변형거동 평가를 위해 지상 LiDAR를 활용한 분석을 실시하였다. 상기와 같이 한국수력원자력(주)에서는 원자력발전소의 지진 등 자연재해에 대한 부지 안전성 평가를 위하여 실시간 부지 감시기반을 구축, 운영하고 있으며 지속적인 관측자료의 분석기법 고도화, 지진 및 단층과의 상관성 분석, 단층 장기 거통특성예측 기술개발을 통하여 보다 견고하게 원자력발전소의 지진안전성 확보에 기여할 수 있을 것으로 기대된다.

발전용 밸브누설 음향 진단 및 감시시스템 (Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves)

  • 이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF