• 제목/요약/키워드: Power Measurement

검색결과 4,631건 처리시간 0.035초

비동기 샘플링에 의한 전력과 에너지 측정 기준시스템 (Electrical Power and Energy Reference Measurement System with Asynchronous Sampling)

  • 위제싱허;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.684_685
    • /
    • 2009
  • A digital sampling algorithm that uses a two high resolution integrating Voltmeters which are synchronized by Phase Lock Loop (PLL) time clock for accurately measuring the parameters, active and reactive power, for sinusoidal power measurements is presented. The PLL technique provides high precision measurements, root mean square (rms), phase and complex voltage ratio, of the AC signal. The system has been designed to be used at the Korean Research Institute of Standards and Science (KRISS) as a reference power standard for electrical power calibrations. The test results have shown that the accuracy of the measurements is better than $10 {\mu}W/VA$ and the level of uncertainty is valid for the power factor range zero to 1 for both lead and lag conditions. The system is fully automated and allows power measurements and calibration of high precision wattmeters and power calibrators at the main power frequencies 50 and 60 Hz.

  • PDF

태양광 발전설비 전력품질 분석 (A Power Quality Analysis of a Photovoltaic System)

  • 정종욱;김선구;최명일
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.579-584
    • /
    • 2009
  • This paper describes a power quality analysis of a photovoltaic generating systems. Prior to the power measurement, domestic and foreign codes related to the photovoltaic generating systems were briefly summarized. After constructing about 5 kW photovoltaic systems, input/output voltages and currents were measured to compare and analyze the power quality by the module type. Based on the measured values, a couple of factors such as active power, power factor, total harmonic distortion(THD) was calculated and analyzed.

Fault Diagnosis of Wind Power Converters Based on Compressed Sensing Theory and Weight Constrained AdaBoost-SVM

  • Zheng, Xiao-Xia;Peng, Peng
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.443-453
    • /
    • 2019
  • As the core component of transmission systems, converters are very prone to failure. To improve the accuracy of fault diagnosis for wind power converters, a fault feature extraction method combined with a wavelet transform and compressed sensing theory is proposed. In addition, an improved AdaBoost-SVM is used to diagnose wind power converters. The three-phase output current signal is selected as the research object and is processed by the wavelet transform to reduce the signal noise. The wavelet approximation coefficients are dimensionality reduced to obtain measurement signals based on the theory of compressive sensing. A sparse vector is obtained by the orthogonal matching pursuit algorithm, and then the fault feature vector is extracted. The fault feature vectors are input to the improved AdaBoost-SVM classifier to realize fault diagnosis. Simulation results show that this method can effectively realize the fault diagnosis of the power transistors in converters and improve the precision of fault diagnosis.

근전계 RCS 측정 오차 요인 및 불확도 분석 (An Analysis of Error Components and Uncertainties in Near-field RCS Measurement)

  • 서민경;태현성;김정규;박호민
    • 한국군사과학기술학회지
    • /
    • 제23권4호
    • /
    • pp.346-354
    • /
    • 2020
  • Nowadays, it is required to apply low observable technology to weapon systems in operation or under development. Radar Cross Section(RCS) is a measure of the scattered power in an given direction when a target is illuminated by an incident wave and used as a parameter to estimate the low observable performance of weapon system. RCS of a target can be calculated by various numerical methods. However, measurement is also needed to estimate RCS of a complex target because it is difficult to estimate theoretically. To acquire reliable measurement results, an analysis of measurement uncertainty is essential. In this paper, error components and uncertainties of near-field RCS measurement system which was constructed in ASTEC(Aerospace System Test & Evaluation Center) were analyzed based on the IEEE recommended practice for radar cross-section test procedures(IEEE Std. 1502-2007) which describes the uncertainty of RCS measurement and unique error components of this near-field measurement system were also identified.

터보샤프트 엔진 고공성능시험의 측정 불확도 평가 (Measurement Uncertainty Assessment of Altitude Performance Test for a Turboshaft Engine)

  • 양인영;이보화
    • 한국추진공학회지
    • /
    • 제14권4호
    • /
    • pp.59-64
    • /
    • 2010
  • 터보샤프트 엔진의 고공성능시험에서 주요 성능 인자인 축마력, 연료 유량, 비연료 소모율 및 공기유량에 대하여 측정의 수학적 모델을 제시하고 측정 불확도를 평가하였다. 터보제트 및 터보팬 엔진의 경우와 비교하여 차이점을 논의하였다. 시험 조건의 측정 불확도를 평가하였으며, 이를 보정된 성능 데이터 측정 불확도에 반영하는 방법을 제시하였다. 실제 터보샤프트 엔진 고공성능시험설비를 이용한 시험 사례에 대한 측정 불확도 평가 결과를 제시하였다. 주요 성능 인자의 측정 불확도는 시험 조건측정의 불확도를 반영하였을 경우 0.65~1.09%, 반영하지 않았을 경우 0.36~0.94%로 평가되었다.

암환자의 삶의 질 도구개발 (Development of Quality of Life Measurement for Cancer Patients)

  • 태영숙;강은실;이명화;박금자
    • 성인간호학회지
    • /
    • 제12권4호
    • /
    • pp.741-757
    • /
    • 2000
  • This study was undertaken to develop an instrument to be used for measuring the concept of quality of life of Korean patients with cancer multidimensionary and correctly. It can contribute in holistic nursing care for Korean cancer patients and also provide and validate basic data to help oncology nurses measure the outcome of nursing intervention correctly. To develop this instrument, the researchers first estabilished a conceptual framework based on the results of qualitative data analysis and indepth interview method Development of the scale was conducted using a method in which 31 items were assessed by subjects' self report using linear analogue scales. The subjects were 79 D.M. patients, 103 patients with acute illness, and 91 cancer patients residing in Busan, Korea. Data were collected during the period from July, 24 to August 14, 2000. This instrument consisted of 31 items with a self report scale. This instrument covered 4 dimensions of cancer patients : 1) physical wellbeing 2) psychological wellbeing 3) social wellbeing and 4)spiritual wellbeing. Each item had a possible score of 10. The reliability of the scale was tested with Cronbach's alpha. Validity was evaluated by examining the relationships of this scale, Youn's Quality of Life Questionnare scores and the Simple Quality of Life scale. Two separate runs of multiple regression were used to predict scores on the Simple Quality of Life measurement. Further validation was obtained by examining the correlation between the instrument subscores and Youn's Quality of Life measurement subscore for convergence of this scale. Examination of the discriminant. power of the instrument was done using ANOVA test. The results are summarized as follows: 1. The reliability of the instrument for the quality of life was 0.8321(Cronbach's alpha.), physical wellbeing dimension 0.6343, psychological wellbeing dimension 0.6501, spiritual wellbeing dimension 0.5883. 2. This instrument had a high correlation with Youn's Quality of Life measurement(r= 0.636) in cancer patients, whereas it had a low correlation with Simple Quality of Life measurement(r=0.455) in cancer patients. In the D.M. patients, the instrument correlated with both the Youn's Quality of Life measurement and Simple Quality of life measurement(r=0.313, r= 0.407) and in the acute stage patients, the instrument had no correlation. 3. Multiple regression of individual items on the Simple Quality of Life scores accounted for 56.8% of the variance in the Simple Quality of Life measurement, whereas, Youn's Quality of Life measurement scores accounts for 31.7%. 4. The correlations collected from the three group had the same patterns of variations but especially the instrument developed in this study had higher disciminant power than that of Youn's Quality of Life Measurement.

  • PDF

MonteCarlo 코드를 이용한 PWR 일차 계통 선원항 평가에 관한 연구 (A Study on the Assessment of Source-term for PWR Primary System Using MonteCarlo Code)

  • 송종순;이상헌;신승수
    • 방사성폐기물학회지
    • /
    • 제16권3호
    • /
    • pp.331-337
    • /
    • 2018
  • 원전 해체는 일반적으로 5단계로 준비, 제염, 절단 및 철거, 폐기물 처리, 환경 복원으로 진행된다. 효율적인 원전 해체를 위해서는 작업자의 안전, 비용 대비 효과, 폐기물 최소화, 재사용 가능성 등이 고려되어야 한다. 또한, 작업자의 안전 및 측정기술이 확보되어야 원전 해체 작업의 최적 효율을 낼 수 있으며 이를 위해서는 계통 및 기기의 정확한 측정 기술이 필요하다. 원전 해체 시 현장에서 사용할 수 있는 대표적인 In-Situ 방법으로는 CZT, Gamma Camera, ISOCS 등이 있다. 본 연구에서는 대표 시료 채취 없이 원전 해체 시 현장에서 적용될 수 있는 ISOCS를 이용하여 S/G Water Chamber 지점에 대하여 측정을 수행하였다. 측정 방법은 ISOCS의 HPGe 검출기를 증기 발생기 수실 하부 중앙을 향해 위치하였으며, 이때 검출기는 주변 방사선장 감소를 위해 납 차폐체를 장착하였다. 차폐체 두께는 5 cm인 원통형 납 차폐체를 장착하였으며, 검출기 전면에는 30도 콜리메이터를 장착하여 측정을 수행하였다. 측정값에 검증을 위해 실제 측정 방법과 동일하게 Microshield를 이용하여 측정한 값과 GEANT4 코드를 이용하여 모델링 하였다. 비교 결과 $1.0{\times}10^1{\sim}1.0{\times}10^2Bq$ 정도 차이를 보였으며, 이는 측정 시 주변 방사선의 영향, 모델링의 정밀도 등으로 오차를 줄일 수 있을 것으로 보인다. 본 논문의 연구 결과를 바탕으로 측정값의 정확도 및 신뢰도를 분석하고 향후 해체 작업 시 직접 측정 방법의 적용성에 대한 신뢰도를 높이고자 한다.

콘크리트의 공극 간격 데이터를 활용한 실측간격계수 개발 (Development of Actual Measurement Spacing Factor Using Spacing Data of Air Void in Concrete)

  • 이진범;전성일;권수안;안지환
    • 콘크리트학회논문집
    • /
    • 제23권6호
    • /
    • pp.701-709
    • /
    • 2011
  • 콘크리트의 공극구조를 평가하기 위한 대표적인 모델 중 하나가 Power가 제안한 간격계수(SF : spacing factor)인데, 이 PSF(power spacing factor)는 평균단일공극 개념을 사용하여 갇힌 공극의 존재 여부에 따라 그 결과값이 실제와 상이하게 나올 수 있는 단점이 있다. 이에 이 연구에서는 실측된 공극 간격 데이터를 이용하여 지수화한 AMSF(실측간격계수 : actual measurement spacing factor)를 개발하였으며, 콘크리트 혼합물의 화상 분석 결과를 이용하여 PSF와 AMSF를 비교 평가하였다. 이 연구 결과, PSF와 AMSF는 전반적으로 유사한 경향을 나타내고 있으나, PSF가 $400{\mu}m$ 이상일 때 전반적으로 AMSF가 좀 더 큰 값을 나타내고 있어, 공기량이 작은 콘크리트 혼합물의 경우 PSF는 실제보다 좀 더 작은 값으로 예측할 가능성이 있는 것으로 나타났다. 또한 갇힌 공극의 유무에 따른 PSF와 AMSF 각각을 분석한 결과, AMSF는 갇힌 공극을 포함하지 않고 분석한 값이 더 크게 나타났고, PSF는 실제와 다르게 갇힌 공극을 포함하지 않고 분석한 값이 더 작게 나타났다. 이와 같이 PSF가 이와 같은 경향을 나타내는 이유는 평균단일공극 개념을 사용하기 때문이며, 이 분석 결과를 통해 AMSF가 좀 더 실제에 가까운 분석기법임을 확인할 수 있었다.

케이블 절연열화진단과 실 계통 적용 (Insulation Diagnostics of Power Cables and Application to Real Distribution System)

  • 이동영;김주용;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1569-1571
    • /
    • 1999
  • In this work, we have performed the application experiment for real distribution line to diagnose the underground power cables using DC voltage decay measurement system. We have also performed the Isothermal Relaxation Current test for the same distribution line using KDA-l. We could confirmed possibility of grading the insulation aging state of underground power cables. Therefore, we conclude that it is possible to apply DC voltage decay method to the real distribution line.

  • PDF