Abstract
The decommissioning of nuclear power plants is generally executed in five steps, including preparation, decontamination, cutting/demolition, waste disposal and environmental restoration. So, for efficient decommissioning of nuclear power plants, worker safety, effects compared to cost, minimization of waste, possibility of reuse, etc., shall be considered. Worker safety and measurement technology shall be secured to exert optimal efficiency of nuclear power plant decommissioning work, for which accurate measurement technology for systems and devices is necessary. Typical In-Situ methods for decommissioning of nuclear plants are CZT, Gamma Camera and ISOCS. This study used ISOCS, which can be applied during the decommissioning of a nuclear power plant site without collecting representative samples, to take measurements of the S/G Water Chamber. To validate the measurement values, Microshield and the GEANT4 code was used as the actual method were used for modeling, respectively. The comparison showed a difference of $1.0{\times}10^1Bq$, which indicates that it will be possible to reduce errors due to the influence of radiation in the natural environment and the precision of modeling. Based on the research results of this paper, accuracy and reliability of measurement values will be analyzed and the applicability of the direct measurement method during the decommissioning of NPPs will be assessed.
Keywords
Decommissioning; In-situ technique; ISOCS; MonteCarlo code; GEANT4;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Massaut Vincent, "Decontamination for Decommissioning Decontamination of Building and concrete", Belgian Nuclear Research Centre, SCK CEN.
2 H.C. Jeong and S.Y. Jeong, "Assessment of the Radiological Inventory for the Reactor at Kori NPP Using In-Situ Measurement Technology", J. Nucl. Fuel Cycle Waste Technol., 12(2), 171-178(2014).   DOI
3 J.G. Choi, "ISOCS V4.2 Calibration Software User Interface" (2015).
4 H.M. Jun, J.H. Kim, J.J. Song, T.U. Kang, J.C. Lee, K.H. Han, and J.S. Seo, "Radioactivity Measurement and efficacy evaluation of 152Eu Radioactive Standard Source of Using the ISOCS", Proc. of the KRS 2016 Spring Conference, 14(1), May 25-27, 2016, Mokpo.
5 G.J. Choi, Study of the Simulation of GEM by Geant4 (2015).
6 GEANT4 User's Guide for Application Developers, Geant4 Collaboration (2016).
7 Electric Power Research Institute, "Application of the EPRI Standard Radiation Monitoring Program for PWR Radiation Field Reduction", Electric Power Research Institute Report, EPRI-1015119 (2007).
8 Korea Institute of Energy Technology Evaluation and Planning, Development of Decontamination Technology of Reactor Coolant System and Dismantled Equipment for NPP Decommissioning, 20141510300310 (2014).
9 Korea Institute of Energy Technology Evaluation and Planning, Assessment of the Radiological Inventory for Decommissioning of Nuclear Power Plants, 201315103 00310 (2013).