• Title/Summary/Keyword: Power Measurement

Search Result 4,625, Processing Time 0.034 seconds

Development of a Remote Power Measurement System to Monitor the Characteristics of a Commercial Power (상용전원 특성 감시를 위한 원격 계측기 개발)

  • Kim, Kyung-Nam;Baek, Yoon-Ki;Yi, Keon-Young;Chang, Yong-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2726-2728
    • /
    • 2005
  • The majority of sensors currently being used for measuring current need to contact with conductor carrying current. Therefore it is not easy to measure and insulate. In order to figure the solution out, the remote power measurement system is introduced in this paper. The system developed here enables us to measure the current of the commercial power without contact by using Rogowski Coil and wireless communication method. Measured current is processed for the wireless transmission, then is transferred to the computer through wireless receiver. The data arrived at the computer is displayed on the screen as waveform.

  • PDF

Process Model for development of EVMS in Nuclear Power Plant Project (원전건설 성과관리시스템(EVMS) 개발을 위한 프로세스 모델 연구)

  • Kim, Yun-Myung;Won, Seo-Kyung;Shin, Il-Sub
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.58-59
    • /
    • 2014
  • EVM(Earned Value Management) is a management methodology for integrating scope, schedule and resources, and for objectively measuring project performance and progress. EVMS(Earned Value Management System) has been used for the performance measurement of R&D and construction projects in developed countries such as United States, United Kingdom and Australia. The nuclear power plant (NPP) projects in Korea have not applied EVMS. However, EVMS has come into request for overall schedule and cost risk management and performance measurement in overseas project of the nuclear power plant as a contractor. In this paper, based on the global EVMS guidelines, EVMS per unit processes have been developed for NPP projects. Moreover, using Business Process Management (BPM), it proposes an integrated process model with tasks, roles, and procedures for EVMS for NPP construction projects.

  • PDF

Measurement and Analysis Harmonics Using DSP (DSP를 이용한 고조파 측정 및 분석)

  • Lee, Sang-Ik;Yoo, Jae-Geun;Jeon, Jeong-Chay
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.178-180
    • /
    • 2002
  • Limitation countermeasure on harmonics occurred by power conversion installation, motor speed control equipment, and so on of power system is very important problem, and first of all, accuracy harmonics analysis in system is required for appropriate limitation counterplan. Analysis and judgement on power system harmonic by measurement are needed because analysis by mathematical model generally used for these harmonic analysis, if nonlinear ingredient is included in system, is not relatively correct. So, in this paper, system to measure and analyze harmonic by installing it in a power system, using DSP(Digital Signal Processor), is designed and developed. Also, it's performance is verified by installing it in the system that harmonics occurred.

  • PDF

Measurement on Vibration Mode of Tire Wheel as a Energy Source of Micro Power (초소형 동력 에너지원으로서의 타이어 휠 진동 모드 측정)

  • Shin, You-Hwan;Lee, Yoon-Pyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.1
    • /
    • pp.64-72
    • /
    • 2009
  • In order to convert efficiently vibration energy of a car tire wheel into electrical power by using piezoelectric materials, the design of the materials must be performed for the dynamic characteristics of the piezoelectric materials to be matched with them of the vibration energy sources well. An accelerometer was installed on the tire wheel with a slip ring to investigate the dynamic mode of the wheel as one of the vibration energy sources. During road test, the measurement on the vibration mode of the tire wheel was performed with variations of car speed and road condition. The experimental data were analyzed details for availability as a micro power source for wireless TPMS(Tire Pressure Monitoring System).

Winding Temperature Measurement in a 154 kV Transformer Filled with Natural Ester Fluid

  • Kweon, Dongjin;Koo, Kyosun
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.156-162
    • /
    • 2013
  • This paper measures the hot spot temperatures in a single-phase, 154 kV, 15/20 MVA power transformer filled with natural ester fluid using optical fiber sensors and compares them with those calculated by conventional heat run tests. A total of 14 optical fiber sensors were installed on the high-voltage and low-voltage windings to measure the hot spot temperatures. In addition, three thermocouples were installed in the transformer to measure the temperature distribution during the heat run tests. In the low-voltage winding, the hot spot temperature was $108.4^{\circ}C$, calculated by the conventional heat run test. However, the hot spot temperature measured using the optical fiber sensor was $129.4^{\circ}C$ between turns 2 and 3 on the upper side of the low-voltage winding. Therefore, the hot spot temperature of the low-voltage winding measured using the optical fiber sensor was $21.0^{\circ}C$ higher than that calculated by the conventional heat run test.

A measuring Method of Ground Resistance for Energized Power Systems (운전중인 전력설비의 접지저항 측정방법)

  • 이복희;김성원;엄주홍;이승칠
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.77-81
    • /
    • 2000
  • The purpose of this paper is to describe a new measuring method of ground resistance for the grounding system in energized power equipment and substations. It is very difficult to measure the accurate ground resistance in energized power equipment and substations because of the noise conducted from all external connections to the grounding system and harmonics components caused by unbalanced loads and overloads. The ground resistance that is measured with existing methods includes not only the effect of desired signals but also noise components for the measurement period in grounding system. The measured value of ground resistance can entirely be different from actual value. In this paper, to eliminate 60[Hz] power system interference and harmonic components the low-pass filter method was used in the measurement of ground resistance.

  • PDF

The Design of FFT Processor for Power measurement using VHDL (VHDL을 이용한 전력 계측용 FFT processor 설계)

  • Lee Jeong-Bok;Park Hae-Won;Kim Soo-Gon;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.657-660
    • /
    • 2002
  • In this paper, the FFT processor for power measurement using VHDL (Very high-speed integrated circuit Hardware Description Language) is discussed. The proposed system relies on the FFT algorithm to compute real and reactive power. The advantage of system is that harmonic analysis is carried out on a period of the Input signal. The proposed system is based on FFT Processor which is designed using VHDL. In the design of FFT processor, $radix-2^2$ is adopted to reduce several complex multipliers for twiddle factor. And this processor adopt pipeline structure. Therefore, the system Is able to have both high hardware efficiency and high performance.

  • PDF

Field Application of Power Cable Diagnosis System (전력케이블 열화진단기법의 현장적용)

  • Kim, Ju-Yong;Han, Jae-Hong;Song, Il-Keun;Kim, Sang-Jun;Lee, Jae-Bong;Oh, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

Experimental Methods for the Measurement of Damping Loss Factors (내부손실계수 측정을 위한 실험 방법)

  • 김관주;최승권
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1187-1192
    • /
    • 1999
  • The purpose of this study is to determine the most appropriate experimental method of the measurement of "damping loss factors" (DLF) for the statistical energy analysis(SEA) calculation. The successful prediction of vibration levels from the structure is critically dependent on the accurate estimation of DLF's not only in conventional vibration analysis but especially in SEA. Unforunately, calculation of accurate DLF is not an easy matter. So experimental methods are made use of for the DLF values. Three kinds of experimental methods for estimating DLF, i.e. decay rate method, half-power bandwidth method and power balance method, are presented and tests are carried out for the plate and the cylindrical shell examples. Pro and con of each methods is reviewed. Finally, calculated DLF values are used for vibration level estimation using commercial SEA software and compared with measured vibration data.tion data.

  • PDF

Development of Power Cable Diagnostic and Insulation Measurement System (전력케이블 열화진단용 측정장치 개발)

  • Yi, Dong-Young;Kwon, Hyuk-Il;Chung, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2126-2129
    • /
    • 1999
  • We have developed the automatic diagnostic system for power cable insulation using DC voltage decay method in this work. Test condition, test method and diagnose criteria of our diagnostic system are adjustable to a class of power cables such as 3.3, 6.6, 11 and 22kV power cables. We have also developed measurement and diagnostic programs for win95 which is suitable for the management of database such as test condition, diagnose results and cable operation data.

  • PDF