• 제목/요약/키워드: Power Facility

검색결과 1,293건 처리시간 0.028초

2 Step 이상 운용 고객의 구내배전계통 지락보호시스템 구성 현황 및 문제점 검토 (A Study on Trouble and Arrangement of the Ground-Fault Protection for 2 Step Voltage Distribution System of Premises)

  • 임진성;신명호
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.73-77
    • /
    • 2010
  • Most accidents occurred in power receiving & transforming facility are ground fault. The quality of power supply is deteriorated since the ground fault is not detected promptly. This paper analyzes the problems about system-grounding type of 2 step power receiving & transforming facility, arrangement of protection relaying scheme and ground-fault protection system of ungrounded system. Then, this paper presents the arranging scheme of system-grounding type to improve power supply reliability.

Application of Logistic Simulation for Transport of SFs From Kori Site to an Assumed Interim Storage Facility

  • Kim, Young-Min;Kim, Chang-Lak
    • 방사성폐기물학회지
    • /
    • 제19권1호
    • /
    • pp.61-74
    • /
    • 2021
  • A paradigm shift in the government's energy policy was reflected in its declaration of early closure of old nuclear plants as well as cancellation of plans for the construction of new plants. To this end, unit 1 of Kori Nuclear Power Plant was permanently shut down and is set for decommission. Based on these changes, the off-site transport of spent fuels from nuclear power plants has become a critical issue. The purpose of this study is to develop an optimized method for transportation of spent fuels from Kori Nuclear Power Plant's units 1, 2, 3, and 4 to an assumed interim storage facility by simulating the scenarios using the Flexsim software, which is widely used in logistics and manufacturing applications. The results of the simulation suggest that the optimized transport methods may contribute to the development of delivery schedule of spent fuels in the near future. Furthermore, these methods can be applied to decommissioning plan of nuclear power plants.

전력계통의 사고전류 저감 설비별 특성 비교 (Comparison of Fault Current Limiting Characteristics According to Facility in Power System)

  • 박형민;최효상;조용선;임성훈;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.127-129
    • /
    • 2005
  • We investigated the fault current limiting characteristics according to the various facilities in power system. Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such as short circuits are increasing higher, which causes the ratings of circuit breakers(CBs) to increase. Upgrading or replacement of CBs is not difficult from the technical and economical point of view. Bus split is being adopted into a part of 154 kV power systems, but it has adverse effects such as overload to neighboring power systems, increased voltage fluctuation, and decreased power system stability. For 345 kV power systems, the bus split measure is not feasible and dc reactors are being suggested. The superconducting fault current limiter is a protection gear of new concept that limits fault current automatically in a few milliseconds. It can also provide the effect of CB capacity increase, relaxation of power machine criteria, enhancement in power system reliability, and flexible power system operation.

  • PDF

단일 이미지 패턴을 이용한 다수의 전력설비 데이터를 증강하기 위한 패턴 배열화 기법 설계 (Design of Pattern Array Method for Multi Data Augmentation of Power Equipment uisng Single Image Pattern)

  • 김석수
    • 융합정보논문지
    • /
    • 제10권11호
    • /
    • pp.1-8
    • /
    • 2020
  • 전력 소비량이 극대화 되면서 개인 전력 중개사업자 및 전력 생산설비의 증가에 따라 전력 설비를 유지, 보수하기 위한 현장 설비 담당자들을 위한 증강현실 기반 모니터링 시스템들에 대한 연구가 활발하게 진행되고 있다. 그러나 기존 증강현실 기반 모니터링 시스템들의 경우 외부 환경, 설비의 복잡성, 조명환경에 대한 간섭 등의 문제로 인하여 정확한 패턴 검출이 어려우며, 전력 설비에 대한 다양한 센싱 정보 및 서비스 정보를 하나의 패턴에 매칭하지 못하는 문제가 있다. 이로 인하여 전력 설비의 센서별로 단일 이미지의 패턴을 이용하여 센서 정보를 매칭하기 때문에 모든 정보를 증강하여 제공하기 위해 다수의 이미지 패턴이 필요하다. 본 논문에서는 다수의 특징 패턴들로 구성된 단일 이미지에서 특징 패턴들의 배열조합을 통해 다수의 정보를 매칭하여 제공하는 단일 이미지 패턴 배열화 기법을 제안한다.

IEC61850용 게이트웨이 개발 및 성능시험 (The Development of IEC61850 Gateway and the Performance Test)

  • 우천희;이보인
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.35-39
    • /
    • 2010
  • The IT project for power plants initiated domestically in 2005 necessitates the power equipment facility and the controllers for those to be sufficiently adaptable for automation system for power substations. This implies that the power plants using power equipments must be developed to satisfy the IEC61850 standards. The IEC61850 communication standards that all power equipment and facility and controllers installed in automation system for power substations must follow has had its Parts 3 and Part 4 established as international standard in January 2002 and Part 10 in May 2005, the last to become international standard. Hence all separate parts of the original IEC61850 standard came to be established as international standards. As a consequence, after 2005, in most power substations around the world the IEC61850 standard is being applied and the prominent makers are geared towards manufacturing products to the IEC61850 standard. The IEC61850 is being recognized as an essential standard that must be applied to not only power substations but for automation of power systems and communication systems. In this research, the Gateway device that connects current SCADA system and IEC61580 based system has been domesticated with Korea‘s own technology and extensive testing was carried out in order to obtain confidence in its performance.

간이합성시험설비를 이용한 가스차단기 개발에 관한 연구 (A Study on A Gas Circuit Breaker Development Using Simplified Synthetic Testing Facility)

  • 정진교;김규탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.902-904
    • /
    • 2007
  • A $SF_6$ gas circuit breakers are widely used for short circuit current interruption in EHV or UHV power system. During a $SF_6$ gas circuit breaker development, Simplified synthetic testing facility is used. This paper shows how simplified synthetic testing facility is used for a SF6 gas circuit breaker development.

  • PDF

회전부를 장착한 터빈 시험장비 개발 (Development of a Rotating Turbine Test Rig)

  • 박응식;송성진;홍용식
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.58-63
    • /
    • 1998
  • To investigate turbine flow fields under realistic conditions, a rotating turbine test facility has been developed at the Inha University Propulsion Laboratory. The experimental facility consists of an air inlet, settling chamber, single turbine stage test section, and diffuser. This turbine has a design flow coefficient of 0.55 and work coefficient of 1.88. The turbine test rig has four features. First, a large scale test section improves space resolution. Second, low speed rpm enhances safety and reduces required power, Third, DC motor/generator is able to regenerate blower power. Fourth, various types of experiment can be carried out.

  • PDF

타워형 태양열 흡수기의 열전달 특성 실험장치에 관한 연구 (Scale Down Design on Experiment Facility of the Water/Steam Receiver for Solar Power Tower)

  • 서호영;김종규;강용혁;김용찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.676-679
    • /
    • 2007
  • This paper describes an experiment facility to measure the circulation characteristics of a water/steam receiver at various heat fluxes. The natural circulation type receiver was considered in this study. The experiment facility was designed to satisfy circulation balance with an appropriate scale down. As a result, riser tube inner diameter was 7.4 mm and water circulation was 0.319 kg/s. Downcomer tube inner diameter by circulation balance was 9.52 mm and the quality was from 0 to 0.23.

  • PDF

무인 설비 감시용 레일 가이드 구동장치에서 BLDC 전동기의 위치 제어 (A Position Control of BLDC Motor in a Rail Guided System for the Un-maned Facility Security)

  • 배종남;이동희
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.223-230
    • /
    • 2017
  • A low-cost BLDC motor with hall sensor is used to drive the position control of a facility security monitoring system in this paper. Low measurable frequency of the hall sensor signal in low-speed regions results in difficulty in obtaining accurate speed detection and position control. To improve system control performance, we propose a variable gain of position controller and stop mode control scheme according to the motor speed and error position with pre-set deceleration time. The proposed stop mode control scheme is activated around the stop position to forcibly move the BLDC motor to the stop position in low speed. In the proposed stop mode, the motor current is controlled by the actual speed with the reference rotating angle. The control performance of the proposed position control is verified through experiments at the actual rail guided facility security monitoring system.

콘크리트 배합설계조건에 따른 레이저 스캐블링 효율성 비교 (Comparison of Laser Scabbling Efficiency According to Concrete Mixing Design Conditions)

  • 허성욱;이재용;정철우;김지현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.156-157
    • /
    • 2021
  • Since concrete is contaminated or radioactive during operation of nuclear power plants, it is the most important radioactive waste generated during the dismantling of a nuclear power plant. The amount of waste is different depending on the pollution state of each facility and the applied technology is different, so there is a big difference. We aim to reduce the amount of waste and increase the value of recyclability through technology to remove radionuclides attached to the surface. For this purpose, laser scabbling, which exfoliates the surface of concrete by irradiating a laser, and a facility system for controlling dust and dust are used in parallel. The purpose of this study is to evaluate the efficiency of laser scabbling by manufacturing simulated concrete for nuclear facilities, and to review the optimal mixing design conditions for nuclear facility structures.

  • PDF