• 제목/요약/키워드: Power Distribution Systems

검색결과 1,303건 처리시간 0.027초

불평형 전압 운전시의 역률보상용 커패시터 특성 연구 (A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation)

  • 김일중;김종겸
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류 (Properties and classification of air discharge by Kohonen network)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

혼합배전계통 선로구성요소 변화를 고려한 선로 서지해석 (Surge Analysis Considering Variation of Line Configuration Factor in Combined Distribution Systems with Power Cables)

  • 김병숙;이장근;한병성;이종범
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.472-480
    • /
    • 2007
  • This paper analyzes overvoltage on testing line for various parameter effect examination. Model systems consist of overhead line and underground cable. The model considered actual characteristic data of distribution lines. and will be constructed at testing yard. The simulations were performed under various line configuration such as cable kinds, cable length, lightning wave, lightning wave time, transformer and branch circuits. The simulation models are established by EMTP/ATPDraw and Line Constants are calculated by ATP_LCC. When lightning surge strikes on conductor of overhead line, EMTP/ATPDraw calculates overvoltage in many cases. Simulation results will be compared with real testing results at testing yard. The compared results will be used to establish protection methods in actual underground distribution systems.

재생이론에 의한 헬리컬 기어장치의 신뢰성에 관한 연구 (A Study on the Reliability of Helical Gear System Using Renewal Theory)

  • 김하수;양성모
    • 한국정밀공학회지
    • /
    • 제15권6호
    • /
    • pp.90-96
    • /
    • 1998
  • Helical gear system is widely used to transmit heavy duty power with harmonies and silences between parallel shafts. This paper predicts a life with Weibull distribution and estimates a reliability based on recycle principle of helical gear systems. 2-parameter Weibull distribution is generally adopted to estimate the mechanical life and the reliability of most gear systems, because this Weibull distribution is proper to explain a characteristics or a life of parts of gear systems with linearity of probability density data on weibull data sheet. For a high reliability, this paper estimates a number of overhaul times and a number of needed substitutes (exchange attachment,1 or parts) with following renewal theory, One is make an exchange of whole module include failure attachments/parts and second estimating method is only exchange of a failure attachments / parts.

  • PDF

분산전원이 연계된 배전선로의 운영시스템 설계 (Operation System Design of Distribution Feeder with Distributed Energy Resources)

  • 김성만;장영학;김경훈;김슬기;문채주
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1183-1194
    • /
    • 2021
  • 전통적으로 전력시스템은 공급체계의 말단에 있는 소비자의 위치에서 보면 중앙집중화된 구조를 갖고 있다. 그러나 최근 수 십년간 지붕형 태양광, 영농형 태양광, 소형 풍력터빈, 배터리저장장치 및 스마트 가전품과 같은 분산에너지원의 등장을 보아왔다. 분산에너지원의 등장에 따라 배전계통 운전원의 역할도 확장된다. 확장된 분산전원의 진출은 배전망이나 송전망의 전통적인 계획과 운영에 영향을 주는 전력계통의 역조류와 예측성을 어렵게 할 수 있다. 이는 전형적인 계통계획, 정비 및 망관리, 정전할당 등 배전계통 운전원이 갖는 기능이 변경되어야 할 필요성을 증폭시킨다. 이 연구의 목적은 다중 분산전원을 갖는 미래 배전운전시스템을 설계하고 제안된 배전시스템 모델을 HILS로 구현 및 검증하는 것이다. 시험결과를 보면 제안된 배전시스템이 정상 영역에서 운전되고 배전선로 손실이 감소된다는 것을 보여준다.

Minimum BER Power Allocation for OFDM-based Cognitive Radio Networks

  • Xu, Ding;Li, Qun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권7호
    • /
    • pp.2338-2353
    • /
    • 2015
  • In this paper, the optimal power allocation algorithm that minimizes the aggregate bit error rate (BER) of the secondary user (SU) in a downlink orthogonal frequency division multiplexing (OFDM) based cognitive radio (CR) system, while subjecting to the interference power constraint and the transmit power constraint, is investigated under the assumption that the instantaneous channel state information (CSI) of the interference links between the secondary transmitter and the primary receiver, and between the primary transmitter and the secondary receiver is perfectly known. Besides, a suboptimal algorithm with less complexity is also proposed. In order to deal with more practical situations, we further assume that only the channel distribution information (CDI) of the interference links is available and propose heuristic power allocation algorithms based on bisection search method to minimize the aggregate BER under the interference outage constraint and the transmit power constraint. Simulation results are presented to verify the effectiveness of the proposed algorithms.

FCM과 유클리디언 기반 거리유사도에 의한 전력용 변압기의 고장진단 (Fault Diagnosis of Power Transformer by FCM and Euclidean Based Distance Measure)

  • 이대종;이종필;지평식;임재윤
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1007-1016
    • /
    • 2007
  • In power system, substation facilities have become too complex and larger according to an extended power system. Also, customers require the high quality of electrical power system. However, some facilities become old and often break down unexpectedly. The unexpected failure may cause a break in power system and loss of profits. Therefore it is important to prevent abrupt faults by monitoring the condition of power systems. Among the various power facilities, power transformers play an important role in the transmission and distribution systems. In this research, we develop intelligent diagnosis technique for predicting faults of power transformer by FCM(Fuzzy c-means) and Euclidean based distance measure. The proposed technique make it possible to measures the possibility and degree of aging as well as the faults occurred in transformer. To demonstrate the validity of proposed method, various experiments are performed and their results are presented.

Study of Harmonic Suppression of Ship Electric Propulsion Systems

  • Wang, Yifei;Yuan, Youxin;Chen, Jing
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1303-1314
    • /
    • 2019
  • This paper studies the harmonic characteristics of ship electric propulsion systems and their treatment methods. It also adopts effective measures to suppress and prevent ship power systems from affecting ship operation due to the serious damage caused by harmonics. Firstly, the harmonic characteristics of a ship electric propulsion system are reviewed and discussed. Secondly, aiming at problems such as resonant frequency and filter characteristics variations, resonance point migration, and unstable filtering performances in conventional passive filters, a method for fully tuning of a passive dynamic tunable filter (PDTF) is proposed to realize harmonic suppression. Thirdly, to address the problems of the uncontrollable inductance L of traditional air gap iron core reactors and the harmonics of power electronic impedance converters (PEICs), this paper proposes an electromagnetic coupling reactor with impedance transformation and harmonic suppression characteristics (ECRITHS), with the internal filter (IF) designed to suppress the harmonics generated by PEICs. The ECRITHS is characterized by both harmonic suppression and impedance change. Fourthly, the ECRITHS is investigated. This investigation includes the harmonic suppression characteristics and impedance transformation characteristics of the ECRITHS at the fundamental frequency, which shows the good performance of the ECRITHS. Simulation and experimental evaluations of the PDTF are carried out. Multiple PDTFs can be configured to realize multi-order simultaneous dynamic filtering, and can effectively eliminate the current harmonics of ship electric propulsion systems. This is done to reduce the total harmonic distortion (THD) of the supply currents to well below the 5% limit imposed by the IEEE-519 standard. The PDTF also can eliminate harmonic currents in different geographic places by using a low voltage distribution system. Finally, a detailed discussion is presented, with challenges and future implications discussed. The research results are intended to effectively eliminate the harmonics of ship electric power propulsion systems and to improve the power quality of ship power systems. This is of theoretical and practical significance for improving the power quality and power savings of ship power systems.

7차 전력수급계획에 따른 송전계통 손실 분석에 관한 연구 (Assessment of Transmission Losses with The 7th Basic Plan of Long-term Electricity Supply and Demand)

  • 김성열;이여진
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.112-118
    • /
    • 2018
  • In recent years, decentralized power have been increasing due to environmental problems, liberalization of electricity markets and technological developments. These changes have led to the evolution of power generation, transmission, and distribution into discrete sectors and the division of integrated power systems. Therefore, studies are underway to efficiently supply power and reduce losses to each sector's demand. This is a major concern for system planners and operators, as it accounts for a relatively high proportion of total power, with a transmission and distribution loss of 4-6%. Therefore, this paper analyzes the status of loss management based on the current transmission and distribution loss rate of each country and transmission loss management cases of each national power company, and proposes a loss rate prediction algorithm according to the long-term transmission system plan. The proposed algorithm predicts the demand-based long-term evolution and the loss rate of the grid to which the transmission plan is applied.