• 제목/요약/키워드: Power Breaking Capacity

검색결과 27건 처리시간 0.025초

지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구 (Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault)

  • 김진태;이승용;박상진;차한주;김수열
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

전력수급의 신뢰도 확보를 위한 고속 인터럽터 동작 특성 (Operational Characteristics of the High-speed Interrupter for Reliability Enhancement of Power Supply and Demand)

  • 최혜원;최효상;정병익
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.143-148
    • /
    • 2013
  • When the fault occurs in power system, the fault-current exceeds breaking capacity of the circuit breaker. So, reliablity of the power system is decreased sharply. Superconducting fault-current limiter (SFCL) is operated without impedance in normal state. The fault-current is limited by its impedance during the fault condition. However, the SFCL has several weak points such as huge size, high-price, liquid-nitrogen operation for the real power system. In this paper, We suggested the high-speed interrupter to limit the fault-current in case of the single line-to-ground fault. In addition, we compared the high-speed interrupter with the SFCL to ensure the operation reliability. The proposed interrupter detected the fault-current through the CT, and the power was supplied by operation of the SCR control system. In this experiment, the power of high-speed interrupter was applied after the 4.8[msec] from fault instant. The on-off operation of the interrupter was started after half-cycle from the fault. The fault-current was flowed into the impedance element by the switching operation of the high-speed interrupter. So, the fault current was limited within one cycle, and then it didnt exceed the capacity of a circuit breaker. We confirmed that there was slight difference between the SFCL with high-speed interrupter in terms of limiting-time of the fault-current and switching speed of the SCR. The high-speed interrupter was considered to be more efficient than the SFCL in size, cost or reliability.

배선용 차단기 개폐기구의 동특성 향상방안 및 해석 (Study on the Dynamic Modeling of MCCB)

  • 박진영;조해용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.315-320
    • /
    • 2012
  • 일반적으로 저압 회로 보호용 장치로는 ICCB(Insulated case circuit breakers), PCB(Power circuit breakers) 그리고 MCCB(Molded case circuit breakers)를 들 수 있다. 이들 중 가장 보편적으로 사용되는 배선용 차단기(MCCB)는 휴즈 또는 개폐기의 단점인 안전성, 제어성, 협조성 등을 보완한 것이다. 차단기의 성능은 사고전류 발생 시 트립 동작이 순간적이고, 절연능력이 뛰어나야 하므로 매우 중요하다. 따라서 차단기의 개폐 성능은 매우 중요하므로 개폐 기구부의 접촉자 구조 및 접점 그리고 링크구조 등에 대한 기구학적 연구가 필요하다. 본 논문에서는 저압차단기의 기구적 동역학 모델링과 해석을 수행하여 가동자의 개리속도가 빠를수록 차단특성에 유리하다는 결론을 얻었으며, 실제 실험을 통하여 이를 검증하였다.

카본블랙내 이온성 불순물들에 따른 반도전 재료(층)의 열적특성 (Thermal Properties of Semiconductive Materials(Shield) by Sonic Impurities in Carbon Black)

  • 이용성;최용성;박대희;이경용
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권4호
    • /
    • pp.149-153
    • /
    • 2005
  • We have investigated thermal properties showed by changing the content of carbon black which is the component parts of semiconductive shield in underground power transmission cable. Specimens were made of sheet with the nine of those for measurement. Heat capacity (${\Delta}$H), glass transition temperature (Tg) and melting temperature (Tm) were measured by DSC (Differential Scanning Calorimetry). The ranges of measurement temperature were from -100($^{\circ}C$) to 100($^{\circ}C$), and heating rate was 4($^{\circ}C$/min). And then thermal diffusivity was measured by LFA 447. The dimension of measurement temperature was 25[$^{\circ}C$]. Glass transition temperature of specimens was showed near -25[$^{\circ}C$] and the heat capacity and the melting temperature from the DSC results were simultaneously decreased according to increasing the content of carbon black, while thermal diffusivity was increased according to increasing the content of carbon black. Because ionic impurities of carbon black having Fe, Co, Mn, Al and Zn are rapidly passed kinetic energy increasing the number of times breaking during the unit time with the near particles according to increasing vibration of particles by the applied heat energy.

가스절연 개폐장치 투입저항의 동특성 해석 (Dynamic Characteristics Analysis of Closing Resistors of Gas Insulated Switchgear)

  • 조해용;이성호;임성삼;이기정;김민우
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.104-110
    • /
    • 2005
  • GIS(Gas Insulated Switchgear) is used in electric power system, to insure non conductivity, breaking capacity and operating reliability. The commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS were used to simulate dynamic analysis of the closing resistors of the GIS in this paper. To reduce chatter vibration of closing resistors, the motion of moving and fixed parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed parts. The simulated results were compared with experimental results. As a result, chatter vibration of closing resistors of the GIS could be reduced by using the results. These data can be used to determine the spring constant, the damping coefficient and mass of a moving part to reduce chatter vibration when the next model is developed.

IEC 표준에 의한 고장전류 계산과 보호협조 (Fault Current Calculation and Coordination by IEC Standards)

  • 손석금
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

Dynamic Analysis on the Closing Resistors of Gas Insulated Switchgear

  • Cho Hae-Yong;Lee Sung-Ho;Lim Sung-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1607-1613
    • /
    • 2006
  • GIS (Gas Insulated Switchgear) is used in electric power system to insure non conductivity, breaking capacity and operating reliability. In the present study, dynamic analysis on the closing resistors of the GIS has bees carried out by the commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS. In order to find the minimum value of chatter vibration of closing resistors, the motion of moving and fixed resistor parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed resistor parts. The simulated results were compared with experimental results. The application of the results could reduce chatter vibration of closing resistors of the GIS. These data are also useful on the development of future model GIS with minimum chatter vibration for the determinations of the spring constant, the damping coefficient and mass of a moving part.

ICP-AES에 의한 반도전재료의 불순물 측정 및 열적특성에 관한 연구 (A Study on Thermal Properties and Impurities Measurement of Semiconductive Shield by ICP-AES)

  • 이경용;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.489-494
    • /
    • 2004
  • In this paper, we investigated impurities content and thermal properties showing by changing the content of carbon black which is semiconductive materials for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Impurities content of specimens was measured by ICP-AES(Inductively Coupled Plasma Atomic Emission Spectrometer), and density of specimens were measured by density meter. And then heat capacity(${\Delta}H$) and melting temperature(Tm), specific heat(Cp) were measured by DSC(Differential Scanning Calorimetry). The dimension of measurement temperature was $0[^{\circ}C]\;to\;200[^{\circ}C]$, and rising temperature was $4[^{\circ}C/min]$. Impurities content was highly measured according to increasing the content of carbon black from this experimental result also density was increased according to these properties. Specially, impurities content values of the A1 and A2 of existing resins were measured more than 4000[ppm]. Heat capacity, melting temperature, and specific heat from the DSC results were simultaneously decreased according to increasing the content of carbon black. Because metallic impurities of carbon black having Fe, Co, Mn, A1 and Zn are rapidly passed kinetic energy increasing the number of times breaking during the unit time with the near particles according to increasing vibration of particles by the applied heat energy.

  • PDF

저압차단기기의 보호협조 (The Protective Co-ordination between Low-Voltage Circuit-Breaker)

  • 박성찬;오준식;이방욱;유만종;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.340-343
    • /
    • 2001
  • In an electrical network, electrical power are transmitted by a various of protection, isolation and control electric circuit devices. This thesis deals with the protection function between circuit-breakers. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. The important advantage of cascading is to be able to install at a branch circuit-breaker of a lesser performance without endangering the safety of the installation for more economical usage. To determine and guarantee co-ordination between two circuit breakers, it is necessary to carry out a theoretical approach, first, and then confirm the results by means of standard tests. This is illustrated in appendix A of IEC 947-2.

  • PDF

$WO_3$를 이용한 박막형 슈퍼캐패시터의 제작 및 특성 평가 (Fabrication and Characterization of Thin Film Supercapacitor using $WO_3$)

  • 신호철;신영화;임재홍;윤영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.575-578
    • /
    • 2000
  • In this work, all solid-state thin film supercapacitor(TFSC) was fabricated using tungsten trioxide (WO$_3$) with a structure WO$_3$/LiPON/WO$_3$/Pt/TiO$_2$/Si (substrate). After TiO$_2$ was deposited on Si(100) wafer by d.c. reactive sputtering, the Pt current collector films were grown on TiO$_2$glue layer without breaking vacuum by d.c. sputtering. Fabrication conditions of WO$_3$ thin film were such that substrate temperature, working pressure, gas ratio of $O_2$/Ar and r.f. power were room temperature, 5 mTorr, 20% (O$_2$(8sccm)/Ar(32sccm)) and 200W, respectively. LiPON electrolyte film were grown on the WO$_3$ film using r.f. magnetron sputtering at room temperature. The XRD pattern of the as-deposited WO$_3$ thin film were shown no crystalline peak (amorphous). The SEM image of as-deposited WO$_3$ thin film showed that the surface is smooth and uniform. The capacitiy of as-fabricated TFSC was 0$\times$10$^{-2}$ F/$\textrm{cm}^2$-${\mu}{\textrm}{m}$.

  • PDF