• 제목/요약/키워드: Potentiodynamic polarization

검색결과 292건 처리시간 0.023초

The Synergistic Effect of 2-Chloromethylbenzimidazole and Potassium Iodide on the Corrosion behavior of Mild Steel in Hydrochloric Acid Solution

  • Zhou, Liben;Cheng, Weizhong;Wang, Deng;Li, Zhaolei;Zhou, Haijun;Guo, Weijie
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권1호
    • /
    • pp.138-147
    • /
    • 2022
  • The synergistic effect of 2-chloromethylbenzimidazole (2-CBI) and potassium iodide (KI) for mild steel in 1 M hydrochloric acid solution was investigated by potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS). The results showed that, with the addition of 100 ppm potassium iodide, the inhibition efficiecy (IE) of 100 ppm 2-CBI in 1 M hydrochloric acid had been improved from 91.14% to 96.15%. And synergistic parameter of 100 ppm 2-CBI with different amounts of potassium iodide is always greater than 1. The adsorption of potassium iodide combining with 100 ppm 2-CBI obeys to the Langmuir adsorption isotherm. Thermodynamic adsorption parameters, including ∆G0ads, ∆Ha and ∆Sa of the adsorption of the combinned inhibitor, as well as the Ea of the mild steel corrosion in 1 M HCl with the combinned inhibitor, were calculated.

새로운 히드라존에 의한 염화물 오염 합성 콘크리트 공극 솔루션에서 철근의 부식 억제에 대한 통찰력 (Insights into the corrosion inhibition of steel rebar in chloride-contaminated synthetic concrete pore solutions by a new hydrazone)

  • 하산 르가즈;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.101-102
    • /
    • 2022
  • A new hydrazone derivatives namely (E)-N'-(4-(dimethylamino)benzylidene)-2-(5-methoxy-2-methyl-1H-indol-3-yl)acetohydrazide (HIND) has been confirmed for mitigating the corrosion of the steel rebar exposed to chloride contaminated synthetic concrete pore solution (ClSCPS). The mitigation of corrosion properties has been characterized by weight loss and electrochemical methods (Electrochemical impedance, Potentiodynamic polarization studies) as well as surface observations. The presence of HIND in the ClSCPS decreased the corrosion of steel rebar by adsorption of HIND molecules on the surface of the steel rebar. The optimal HIND concentration was 0.5 mmol/L, corresponding to an inhibition efficiency of 88.4%. The use of HIND enables the corrosion process to have a higher energy barrier. X-ray photo electron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy-energy-dispersive spectroscopy (SEM-EDS), and X-ray diffraction (XRD) spectroscopy interpretations confirmed that HIND mitigates the corrosion attack on the surface steel rebar.

  • PDF

플라즈마 산질화처리된 AISI 420 마르텐사이트 스테인레스 강재의 표면 경도 및 부식 거동 (Surface Hardness and Corrosion Behavior of AISI 420 Martensitic Stainless Steels Treated by Plasma Oxy-Nitriding Processing)

  • 김진한;이광민
    • 한국재료학회지
    • /
    • 제33권7호
    • /
    • pp.309-314
    • /
    • 2023
  • This study aimed to address the limitations of traditional plasma nitriding methods by implementing a short-term plasma oxy-nitriding treatment on the surface of AISI 420 martensitic stainless steel. This treatment involved the sequential formation of nitride and oxide layers, to enhance surface hardness and corrosion resistance, respectively. The process resulted in the formation of a 20 ㎛-thick nitride layer and a 3 ㎛-thick oxide layer on the steel surface. Initially, the hardness increased by 2.2 times after nitriding, followed by a subsequent decrease of approximately 31 % after oxidation. While the nitriding process reduced corrosion resistance, the subsequent oxidation process led to the formation of a passive oxide film, effectively resolving this issue. The pitting corrosion of the oxide passive film started at 82.6 mVssc, providing better corrosion resistance characteristics than the nitride layer. Consequently, the trade-off between surface hardness and corrosion resistance in plasma oxy-nitrided AISI 420 martensitic stainless steel is anticipated to be recognized as an innovative and comprehensive surface treatment process for biomedical components.

TiN 및 WC코팅된 치과용 어버트먼트 나사의 안정성 (Stability of TiN and WC Coated Dental Abutment Screw)

  • 손미경;이충환;정재헌;정용훈;최한철
    • 한국표면공학회지
    • /
    • 제41권6호
    • /
    • pp.292-300
    • /
    • 2008
  • Dental implant system is composed of abutment, abutment screw and implant fixture connected with screw. The problems of loosening/tightening and stability of abutment screw depend on surface characteristics, like a surface roughness, coating materials and friction resistance and so on. For this reason, surface treatment of abutment screw has been remained research problem in prosthodontics. The purpose of this study was to investigate the stability of TiN and WC coated dental abutment screw, abutment screw was used, respectively, for experiment. For improving the surface characteristics, TiN and WC film coating was carried out on the abutment screw using EB-PVD and sputtering, respectively. In order to observe the coating surface of abutment screw, surfaces of specimens were characterized, using field emission scanning electron microscope(FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The stability of TiN and WC coated abutment screw was evaluated by potentiodynamic, and cyclic potentiodynamic polarization method in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion potential of TiN coated specimen was higher than those of WC coated and non-coated abutment screw. Whereas, corrosion current density of TiN coated screws was lower than those of WC coated and non-coated abutment screw. The stability of screw decreased as following order; TiN coating, WC coating and non-coated screw. The pitting potentials of TiN and WC coated specimens were higher than that of non-coated abutment screw, but repassivation potential of WC coated specimen was lower than those of TiN coated and non-coated abutment screws due to breakdown of coated film. The degree of local ion dissolution on the surface increased in the order of TiN coated, non-coated and WC coated screws.

Ni-Cr과 Co-Cr 합금을 이용한 치과보철물의 부식 특성 및 도재 접합성 (Corrosion Characteristics of Ni-Cr and Co-Cr Alloy Used as a Dental Prosthesis and Its Adhesion to Porcelain)

  • 김기정;최병기;오두록;최병상
    • Corrosion Science and Technology
    • /
    • 제15권3호
    • /
    • pp.141-146
    • /
    • 2016
  • By using Ni-Cr and Co-Cr alloys, porcelain fused to metal (PFM) samples were prepared to examine the interface and the surface corrosion behavior. The potentiodynamic polarization analysis showed that the corrosion current density of Co-Cr alloy ($1.61{\times}10^{-6}A/cm^2$) was three times lower than that of Ni-Cr alloy ($4.83{\times}10^{-6}A/cm^2$) at room temperature. A dental prosthesis consisting of the porcelain fused to Ni-Cr alloy extracted from a patient after approximately four years of usage was examined to assess its resistance to corrosion. OM and SEM images of the metal part revealed a typical pitting corrosion. As compared to porcelain fused to Ni-Cr alloy having a thick layer (${\sim}10{\mu}m$) of oxide at the interface, a relatively thin oxide layer (less than $5{\mu}m$) was formed on Co-Cr alloy, indicating that the interface between Co-Cr alloy and porcelain may have a better adhesion strength than the interface between Ni-Cr alloy and porcelain.

The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V)

  • Huang, Gui-Yue;Jiang, Heng Bo;Cha, Jung-Yul;Kim, Kwang-Mahn;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제47권5호
    • /
    • pp.306-312
    • /
    • 2017
  • Objective: The purpose of this study was to examine the effect of commercially available fluoride-containing oral rinses on the corrosion behavior of titanium alloys, which are the main components of orthodontic miniscrews. Methods: Four commercially available oral rinses (solution A, pH 4.46/260 ppm fluoride; solution B, pH 4.41/178 ppm fluoride; solution C, pH 6.30/117 ppm fluoride; and solution D, pH 4.17/3.92 ppm fluoride) were tested on titanium alloy (Ti-6Al-4V) circular plates, and saline was used as the control. The open-circuit potential and potentiodynamic polarization of these materials were measured. Thereafter, all samples were evaluated under a field-emission scanning electron microscope. Results: Among the tested oral rinses, except solution D, the more the fluoride content was, the greater was the corrosion potential downtrend; the corrosion resistance of the titanium alloy sample was also lowered significantly (p < 0.05). Field-emission scanning electron microscopic analysis of the surface morphology of the titanium alloy samples revealed that all samples had some defects, crevices, or pitting after exposure to the oral rinses than before treatment. In particular, the samples in solution A showed the most changes. Conclusions: Commercially available oral rinses having a high fluoride concentration and a low pH may reduce the corrosion resistance of titanium alloys used in dental appliances such as orthodontic titanium miniscrews and brackets.

그래핀의 합성과 열전도 및 표면 특성 개선 활용 (Synthesis of graphene and its application to thermal and surface modification)

  • 김용유;장희진;최병상
    • 한국전자통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.549-554
    • /
    • 2013
  • CVD를 이용하여 Cu 시편에 그래핀의 합성을 보이고, Cu 시편의 grain 크기와 방향성에 따른 그래핀의 성장거동을 보이고자 한다. 동일한 온도 및 압력 하에서도 사용하는 분위기 가스의 종류에 따라서 Cu의 확산에 영향을 주게 되고, 그래핀 합성 시 사용되는 $H_2$$CH_4$ 가스 분위기 하에서 Cu grain의 성장에도 영향을 미치는 것을 알 수 있었으며, 결과적으로 Cu grain의 성장이 그래핀의 합성과 성장에 직접적인 관련이 있음을 보이고자 하였다. 부식 저항성은 상온에서 동전위 분극실험를 통하여 분석하였으며, 부식속도 비교에서 그래핀 코팅된 Cu 시편의 경우가 그래핀의 화학적 안정성에 기인하여 순수 Cu 시편의 경우보다 동일한 부식 환경에서 약 10배 정도 안정적인 것으로 관찰이 되었다. 또한, grain boundary를 포함, 결함이 없는 그래핀의 균일한 성장의 가능성을 보이고, 이의 합성을 통한 공학적인 활용이 그 최종적인 목적이 될 것이다.

용융가압함침공정으로 제조된 TiC 세라믹 입자 강화 철강복합재의 염수환경에서의 부식 특성 (Corrosion Behaviors of TiC Ceramic Particulate Reinforced Steel Composites Fabricated by Liquid Pressing Infiltration Process in Salt Water Environment)

  • 이영환;고성민;신상민;조승찬;김양도;김정환;이상관;이상복
    • Composites Research
    • /
    • 제33권5호
    • /
    • pp.251-255
    • /
    • 2020
  • 본 연구에서는 용융가압함침공정을 이용하여 제조된 TiC 세라믹 입자강화 철강복합재를 제조하고 상용구상흑연주철과 비교를 위하여 미세조직 분석 및 경도 등 기초물성과 선박 해양 분야등의 적용가능성 검토를 위하여 염수환경에서의 부식 특성에 관한 연구를 진행하였다. 염수환경에서의 부식특성 비교 결과 구상흑연주철 대비 부식전위와 부식전류밀도 모두 낮은 값을 나타내었고, 낮은 연간부식률을 통하여 TiC-Fe 금속복합재의 내식성이 더 뛰어난 것을 확인하였다.

부식액의 조건 및 주사 속도가 AISI 304 스테인리스강의 전기화학적 부식에 미치는 영향 (Effect of the Corrosive Solution Conditions and Scan Rate to the Electrochemical Corrosion on the AISI 304 Stainless Steel)

  • 나은영;백신영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권5호
    • /
    • pp.535-541
    • /
    • 1997
  • The effect of concentration of each solution( HCI, $H_2SO_4$ and $HNO_3$), scan rate and polished surface condition on the corrosion of AISI 304 Stainless Steel were investigated, utilizing the Method ASTM G5 - 87. It can be concluded that: 1) For the same concentration(i.e. 1N) of each solution the corrosion rate is the highest in HCI and lowest in $HNO_3$. Also, the difference of values of $i_{cirt}$ generated for each solution is significant. 2) As the concentration of the solution $H_2SO_4$ is increased (O.5N, 1N, 2N) the values of $E_{cor}$ $i_{crit}$ and $i_{p}$ are increased. 3) In case of existence of SCN ion of O.OlN, the values of iCTIt and ip generated are approximately 100 times and 1.4 times higher respectively, than in the case of non - existence of $SCN^{-}$. However the existence of $SCN^{-}$ doesn't affect the value of $E_{cor}$ and $E_{p}$. 4) The values of $i_{crit}$ and $i_{p}$ are increased due to the increase of scan rate. But the values of $E_{cor}$ and $E_{p}$ do not depend on the scan rate. 5) The $i_{p}$ value depends greatly on oxygen in the solution, but the changes in values of $E_{cor}$ $i_{crit}$ and $E_{b}$ due to the oxygen are insignificant. 6) If a component is polished using #400, #600 and #800 wet polish paper, the effect of surface condition on variations of values of $i_{crit}$ and $i_{p}$ is slightly significant.

  • PDF

Nb이 첨가된 Ti합금의 내식성 및 생체안정성 (Effects of Nb Addition on Corrosion Resistance and Cytotoxicity Behavior of Ti Alloys)

  • 이도재;이광민;이경구;유창남;오태욱;김수학;윤택림
    • 한국재료학회지
    • /
    • 제13권11호
    • /
    • pp.761-768
    • /
    • 2003
  • The corrosion resistance and cytotoxicity behavior of Ti alloys were studied as a function of Nb contents(3wt.%Nb, 20wt.%Nb, 40wt.%Nb). Ti-Nb alloys were melted by vacuum arc furnace and then rolled to 50% reduction ratio after homogenized at 105$0^{\circ}C$ for 24hrs. The corrosion resistance of Ti-Nb alloys were investigated by potentiodynamic polarization test in the 0.9% NaCl and 5% HCI solution. Biocompatibility of Ti-Nb alloys was evaluated by cytotoxicity test. The results can be summarized as follows 1) The microstructure change from equiaxial to acicular and the increased $\beta$ phase in Ti-Nb alloys were obtained as the Nb content increased. 2) For the corrosion test in the solution of 0.9% NaCl and 5% HCI, the corrosion behavior of Ti-Nb alloys was similar to ASTM grade 2 CP Ti. 3) For the cytotoxicity test, Ti-Nb alloys showed excellent biocompatibility compared to ASTM grade 2 CP Ti, 316L STS and Co-Cr alloys.