• 제목/요약/키워드: Potential flow

검색결과 2,203건 처리시간 0.035초

선박용 AA5083-H321의 유속에 의한 침식손상 방지를 위한 최적 음극방식전위 규명 (Investigation of Optimum Cathodic Protection Potential to Prevent Erosion with a Flow Rate of AA5083-H321 for Marine Vessels)

  • 정상옥;박일초;김성종
    • Corrosion Science and Technology
    • /
    • 제19권6호
    • /
    • pp.288-295
    • /
    • 2020
  • This study investigated the erosion-corrosion characteristics of 5038-H321 aluminum alloy in a natural seawater solution through various electrochemical experiments and flow rate parameters. Cathodic polarization experiments were conducted at flow rates ranging from 4 to 12 knots. Considering the concentration polarization section representing a relatively low current density, the range of the potentiostatic experiment was determined to be -1.6 to -1.0 V. The potentiostatic experiment was conducted at various potentials for 180 minutes in seawater. After the experiment, the corrosion characteristics were evaluated by observing surface morphology and measuring surface roughness. As a result, as the applied potential was lower, the amount of calcareous deposits increased and the roughness tended to increase. On the other hand, it was confirmed that the roughness was larger in the static condition than the flow rate condition due to the influence of the flow velocity. Variations in the chemical composition with flow rate variations were analyzed by energy-dispersive spectroscopy (EDS). In conclusion, the cathodic potential of AA5083-H321 in seawater was determined to be -1.0 V.

하전된 멤브레인 미세기공에서의 계면동전기적 유동에 의한 흐름전위: 비선형 Poisson-Boltzmann 전기장을 갖는 경우 (Electrokinetically Flow-Induced Streaming Potential Across the Charged Membrane Micropores: for the Case of Nonlinear Poisson-Boltzmann Electric Field)

  • Myung-Suk Chun
    • 멤브레인
    • /
    • 제13권1호
    • /
    • pp.37-46
    • /
    • 2003
  • 하전된 멤브레인 미세기공으로 유체가 흐르는 경우는 계면동전기 효과가 작용하게 된다. 비선형 Poisson-Boltzmann 전기장과 흐름에 의해 유발되는 전기장 사이의 정전상호작용을 운동방정식의 외부작용 힘으로 고려하였다. 유한차분법으로 정전위 분포를 우선 산출하고, 이어서 Green 함수로 슬릿형 기공에 대한 Navier-Stokes 식의 해석해를 구하였다. 계면동전기적 유동에 의한 흐름전위를 관련된 물리화학적 인자들의 함수로 유도되는 해석적인 명확한 표현으로 제시하였다. 전기이중층, 표면전위, 그리고 기공벽면의 하전조건의 영향에 따른 유속분포와 흐름전위 변화를 고찰하였다 계산결과, 전기이중층 두께나 표면전위가 증가함에 따라 평균유속은 감소하는 반면에 흐름전위는 증가하였다.

COMPUTATION AND ANALYSIS OF MATHEMATICAL MODEL FOR MOVING FREE BOUNDARY FLOWS

  • Sohn, Sung-Ik
    • 대한수학회지
    • /
    • 제37권5호
    • /
    • pp.779-791
    • /
    • 2000
  • The nonlinear stage of the evolution of free boundary between a light fluid and a heavy fluid driven by an external force is studied by a potential flow model with a source singlarity. The potential flow model is applied to a bubble and spije evolution for constantly accelerated interface (Rayleigh-Taylor instability) and impulsively accelerated interface (Richtmyer-Meshkow instability). The numerical results of the model show that, in constantly accelerated intergace, bubble grows with constant velocity and the spike falls with gravitational acceleration at later times, while the velocity of the bubble in impulsively accelerated interface decay to zero asymp flow model for the bubble and spike for constantly accelerated interface and impulsively accelerated interface.

  • PDF

2차원 비정상유동 해석을 위한 1-방정식 방법 (An one equation method for two dimensional unsteady flows)

  • 조지룡
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 춘계 학술대회논문집
    • /
    • pp.113-123
    • /
    • 1999
  • 본 연구에서는 3차원, 비압축성 유동에 적용 가능한 순수 벡터 포텐셜 방법 (Pure Vector Potential Method, PVPM for short)의 정식화를 수행하였고, 2차원의 경우에 적용 가능한 수치적 방법과 경계조건의 부여법을 상세히 설명하였다. 이 방법의 타당성을 검증하기 위하여 급작스럽게 출발하는 벽구동 웅덩이 내부 유동과 엄밀해가 존재하는 Stokes의 제 1문제를 수치해석하였다. 계산 결과들은 이 두 유동의 중요한 거동을 매우 잘 묘사하였다.

  • PDF

1단 축류 터빈의 비정상 내부유동특성에 관한 2차원 해석 (II) (Two-Dimensional Analysis of Unsteady Flow Through One Stage of Axial Turbine (II))

  • 박준영;엄인식;백제현
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1518-1526
    • /
    • 2001
  • In this paper, the mechanism of unsteady potential interaction and wake interaction in one stage axial turbine is numerically investigated at design point in two-dimensional viewpoint. The numerical technique used is the upwind scheme of Van-Leer's Flux Vector Splitting (FVS) and Cubic spline interpolation is applied on zonal interface between stator and rotor. The inviscid analysis is used to embody the influence of potential interaction only and viscous analysis is used to embody the influences of both potential interaction and wake interaction at the same time. The potential-flow disturbance from the stator into a rotor passage and the periodic blockage effect of rotor produce the unsteady pressure on the blade surface in inviscid analysis. After the wake is cut by rotor, two counterrotating votical patterns flanking the wake centerline in the passage are generated. So, these phenomena magnify the unsteady pressure in viscous analysis than that in inviscid analysis. The resulting unsteady forces on the rotor, generated by the combined interaction of the two effects by potential and wake interaction, are discussed.

Development of Wave and Viscous Flow Analysis System for Computational Evaluation of Hull Forms

  • Kim, Wu-Joan;Kim, Do-Hyun;Van, Suak-Ho
    • Journal of Ship and Ocean Technology
    • /
    • 제4권3호
    • /
    • pp.33-45
    • /
    • 2000
  • A computational system for wave and viscous flow analysis (WAVIS) has been developed. The system includes a pre-processor, flow solvers and a post-processor. The pre-processor is composed of full form presentation, surface mesh and field grid generation. The flow solvers are for potential and viscous flow calculation. The post-processor has graphic utility for result analysis. All the programs are integrated in a GUI-launcher package. To validate the developed CFD programs of WAVIS, the calculated results for modern commercial hull forms are compared with measurements. It is found that the results from WAVIS are in good agreement with the experimental data, illustrating the accuracy of the numerical methods employed for WAVIS.

  • PDF

포텐셜 코어내에 설치된 충돌평판상의 열전달증진 및 유동특성에 관한 연구 (Study on the flow characteristics and heat transfer enhancement on flat plate in potential core region of 2-dimensional air jet)

  • 이용화
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.193-201
    • /
    • 1998
  • A heat exchanging system employing the impinging air jet is still widely used In the various fields due to its inherent merits that include the easiness in engineering applications and the high heat and/or mass transfer characteristics. The purpose of this study is to investigate the enhancement of heat transfer and flow characteristics by placing a turbulence promoters in front of heat exchanging surface. In this study, a series of circular rods are placed at the upstream of a flat plate heat exchanger that is located at potential core region(H/W=2) of a two-dimensional impinging air jet. Heat transfer enhancement is achieved by inserting turbulence promoter that results in the flow acceleration and disturbance of boundary layer. The average Nusselt number of the flat plate with the turbulence promoters is found to be around 1.42 times higher than that of the flat plate without the turbulence promoters. Based on the results of flow visualization with a smoke wire, it is confirmed that the heat transfer enhancement is caused by the flow separation and disturbance of boundary layer by inserting the turbulence promoter.

  • PDF

다공성 실리콘막을 포함한 전기침투 방식 펌프에서의 비대칭적 인 유동 (Asymmetric Flows for Porous Silicon Electroosmotic Pumps)

  • 김대중
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.703-704
    • /
    • 2008
  • We fabricated and tested porous silicon-based electroosmotic pumps. Compared to other pumping media, porous silicon is beneficial for obtaining comparable flow rates with much lowered electric potential, while maintaining enough mechanical properties. We fabricated porous silicon with two sided-reactive etching processes. We found higher flow rate per electric potential (consistent with previous studies) and we also found asymmetric flow rates for different pumping directions. We plan to utilize this asymmetry for AC pumping applications.

  • PDF

ASYMPTOTIC SOLUTIONS OF HYDRODYNAMIC INTERFACIAL INSTABILITIES IN CYLINDRICAL FLOW

  • Sohn, Sung-Ik
    • 한국수학교육학회지시리즈B:순수및응용수학
    • /
    • 제20권4호
    • /
    • pp.259-267
    • /
    • 2013
  • We present a high-order potential flow model for the motion of hydrodynamic unstable interfaces in cylindrical geometry. The asymptotic solutions of the bubbles in the gravity-induced instability and the shock-induced instability are obtained from the high-order model. We show that the model gives significant high-order corrections for the solution of the bubble.

마이크로 채널 내부 전기삼투 유속 측정을 통한 유리표면의 Zeta-potential 측정 (Zeta-potential Measurement on Glass Surface by Measuring Electro-osmotic Velocity inside a Micro-channel)

  • 한수동;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.80-84
    • /
    • 2005
  • Many important properties in colloidal systems are usually determined by surface charge ($\zeta$-potential) of the contacted solid surface. In this study, $\zeta$-potential of glass $\mu$-channel was evaluated from the electro-osmotic velocity distribution. The electro-osmotic velocity inside a glass $\mu$-channel was measured using a micro-PIV velocity field measurement technique. This evaluation method is more simple and easy to approach, compared with the traditional streaming potential technique. The $\zeta$-potential in the glass $\mu$-channel was measured for two different mole NaCl solutions. The effect of an anion surfactant, sodium dodecyl sulphate (SDS), on the electro-osmotic velocity and $\zeta$-potential in the glass surface was also studied. In the range of $0\∼6$mM, the surfactant SDS was added to NaCl solution in four different mole concentrations. As a result, the addition of SDS increases $\zeta$-potential in the surface of the glass $\mu$-channel. The measured $\zeta$-potential was found to vary from-260 to-70mV. When negatively charged particles were used, the flow direction was opposite compared with that of neutral particles. The $\zeta$-potential has a positive sign for the negative particles.

  • PDF