• Title/Summary/Keyword: Potential Transformer

Search Result 122, Processing Time 0.038 seconds

Experimental Study of Impulsive High Current Generating Apparatus (충격전류발생장치의 실험적연구)

  • An Kyun Kim
    • 전기의세계
    • /
    • v.24 no.4
    • /
    • pp.73-76
    • /
    • 1975
  • In this study, a design scheme of an impulsive high current generating device is presented. The device is proved to be effective in producing rather complex type of the permanent magnet. Principally, the apparatus designed same to the ordinary potential transformer or current transformer, but, it has a certain differences that the primary winding of many turns is excited by d.c. source and the secondary winding of a few turns induce low voltage and high current at the instant when opening a switch in the primary circuit. This paper does not include magnet production process. Rather, it deals with the analytical studies of the devices, the designing procedure of the experimental setup, and some results from the experimental data are presented as a preliminary study. The experimental results are found to agree well with the theoritical analysis presented in this paper.

  • PDF

Development of Optical CT and PT using BSO Single Crystal (BSO를 이용한 광CT, PT 개발)

  • Shin, K.H.;Lee, B.K.;Cho, H.K.;Kim, Y.H.;Kim, Y.S.;Park, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.491-494
    • /
    • 1992
  • This paper described the development example of optical CT(Current Transformer) and optical PT (Potential Transformer) which is measurement system of current and voltage of electric power line using Electro-Optic effect and Magneto-Optic effect. We designed the optical CT of 22KV class and 154KV class and an optical PT of 22KV class. And now the filed testing is in progress in a KEPCO's substation.

  • PDF

Review on tolerance factors for 1E UVR setting at NPPs (원전 안전등급 저전압계전기 설정시 오차함수 검토)

  • Moon, Su-Cheol;Kim, Kern-Joong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.367-372
    • /
    • 2012
  • In nuclear plants, UVR (under voltage relay, 27r) of 1E bus, which protected and supplied power to essential loads, to safety trip of reactor and supplied to starting signal of EDG (emergency diesel generators) automatically. therefore UVR tolerances setting and calculation method has been important to nuclear facility. If calculation and tolerances values differ or ignore, may induced power loss and economical loss by protective failure. This paper show results for calculation methods, and whether dependant or independent methods for factors. included whether PT (potential transformer/voltage transformer) tolerance or not adapted, and based on UVR setting method within a difference minimum and maximum of rated voltage to safety operation in nuclear plants.

Investigation of Excitation System for Nuclear Emergency Diesel Generator (원전 비상디젤발전기 여자시스템 고찰)

  • Shin, Man-Su;Lee, Joo-Hyun;Lim, Ick-Hun;Jeong, Tae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1894-1895
    • /
    • 2007
  • It is excitation system for nuclear emergency generator that is to startup automatically and sequentially supply essential loads with power. There are static type and alternating exciter, etc in its excitation system. An object of study is static excitation system which power is taken from power potential transformer and power current transformer. It is to complement curtailment of excitation system ability at happening short accidents. And Startup mode are quick startup and slow startup, etc. Its characteristic is looked into in this paper.

  • PDF

Numerical Analysis of Resin Filling Process for a Molded Dry-type Potential Transformer (몰드형 건식 계기용 변압기 제작을 위한 수지 충진 해석 연구)

  • Kim, Moosun;Jang, Dong Uk;Kim, Seung Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.511-517
    • /
    • 2016
  • Current oil-type potential transformers for trains are filled with insulating oil, which could have problems like explosions due to rising inner pressure during train operation. Therefore, mold and dry-type potential transformers are being developed to prevent explosions. One problem in manufacturing mold-type transformers is preventing void formation around the coiled core inside the mold during epoxy filling, which could cause an electrical spark. Micro voids can remain in the resin after filling, and macro voids can occur due to the structure shape. A transformer that is being developed has a cavity at the junction of the core and the coil for better performance, and when highly viscous epoxy flows inside the cavity channel, macro voids can form inside it. Therefore, in this study, the free-surface flow of the mold filling procedure was analyzed numerically by applying the VOF method. The results were used to understand the phenomena of void formation inside the cavity and to modify the process conditions to reduce voids.

Development of Analog Controlled Transformer-fed Static Excitation System (정지형 여자제어 시스템 개발)

  • Lim, I.H.;Rhew, H.S.;Jung, C.K.;Rhew, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2184-2186
    • /
    • 1997
  • Potential-source controlled rectifier excitation system has been developed by KEPRI for synchronous generator in YOUNG-DONG thermal power plant. This paper describes the characteristics of redundant control system and transfer function of dual channel excitation control system. This system has been using a analog and digital circuit devices(hybrid type)

  • PDF

A Numerical Model of the Electric Field Distribution in Power Transformers (전력용 변압기의 절연유가 전계에 미치는 수치해석적 모델)

  • Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.3-6
    • /
    • 1990
  • The impact of the convected charges, which is caused by the electrification phenomina, in the oil-paper insulation systems of power transformers has been numerically investigated using FEM. The potential distribution of the oil-paper insulation system is assumed to be governed by three equations instead of the classical Laplace equation. When the charge density of oil and the conduction current are kept high, the field distortion or the interrace in a power transformer is considerably distorted due to the convected charges.

  • PDF

Development of 132 kV Standard Potential Transformer and Stability Test (132 kV 초정밀 전압변성기(PT) 개발 및 안정도 평가)

  • Kwon, Sung-Won;Lee, Sang-Hwa;Jung, Jae-Kap;Kim, Mun-Seog;Kim, Jae-Young;Lee, Sung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1387_1388
    • /
    • 2009
  • High accurate and stable 132 kV potential transformers (PTs) including 66 kV & 22 kV PT with stability of less than 0.0033 % for 13 month and with ratio error within $\pm$ 0.024 % at full rated voltage have been developed. The PTs are useful as the reference PT of the PT comparator system in the voltage range of 11 kV to 132 kV PT.

  • PDF

Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter (저항접지 시스템에서 지락사고시 CLR과열 소손방지를 위한 GPT 정격용량의 적정성 연구)

  • Shin, Ho-Jeon;Kim, Jin-Seok;Park, Yu-Hwan;Kim, Jae-Chul;Cho, Man-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.503-508
    • /
    • 2012
  • Among the high distribution voltage consumers, high-capacity consumers are often applying the grounding resistance method in order to overcome demerits such as erroneous operation of the ground reply or potential increase in the battery at the accident of the isolated neutral system. In this paper, to prevent damage to CLR and GPT in the delay to block the breakdown in the resistance grounded neutral system, this study aims to provide a proper suggestion for continuous rating capacity of GPT to check the appropriateness of CLR size and reduce GPT burden. Thereupon, this study comparatively analyzes CLR current applied in general GPT and the current gained when CLR demanded in the system is used and analyzes the simulated system through simulation using PSCAD/EMTDC in order to suggest GPT's proper continuous rating capacity.

A study on an earthing system without ground connection (대지에 매설할 필요가 없는 접지시스템에 관한 연구)

  • Seol, Dong-Hwa;Kim, Chang-Bong;Woo, Jea-Wook
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.258-261
    • /
    • 2009
  • This paper proposes an earthing system without ground connection. As a Green IT Environmental Solution, Internal-external surge and other unnecessary electric currents are converted into energy and through a discharge the signal is reduced. It's a structure that discharges through a neutral electric transformer. The results show that the electric potential rising of the earthing system proposed in this paper are approximately below the half and the discharge currents increased approximately 9 times when compared to existent earthing systems. This earthing system is economical, easy to install and can solve environmental contamination.

  • PDF