• Title/Summary/Keyword: Posterior transpedicular fixation

Search Result 13, Processing Time 0.025 seconds

Post-traumatic Atlantoaxial Rotatory Dislocation in an Adult Treated by Open Reduction and C1-C2 Transpedicular Screw Fixation

  • Kim, Yeon-Seong;Lee, Jung-Kil;Kim, Jae-Hyoo;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.4
    • /
    • pp.248-251
    • /
    • 2007
  • Atlantoaxial rotatory dislocation [AARD] is an uncommon disorder of childhood in which clinical diagnosis is generally difficult and often made late. It is very rare in adults because of the unique biomechanical features of the atlantoaxial articulation. We report a case of post-traumatic AARD in an adult. Reduction was difficult to obtain by skull traction and gentle manipulation. Therefore, the patient was treated surgically by an open reduction, transpedicular screw fixation, and posterior C1-2 wiring with graft. The normal atlantoaxial relation was restored with disappearance of torticollis. Postoperatively, the patient remains neurologically intact and has radiographic documentation of fusion. Atlantoaxial transpedicular screw fixation can be one of the treatment options for the AARD.

A Biomechanical Comparison among Three Surgical Methods in Bilateral Subaxial Cervical Facet Dislocation

  • Byun, Jae-Sung;Kim, Sung-Min;Choi, Sun-Kil;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.2
    • /
    • pp.89-95
    • /
    • 2005
  • Objective: The biomechanical stabilities between the anterior plate fixation after anterior discectomy and fusion (ACDFP) and the posterior transpedicular fixation after ACDF(ACDFTP) have not been compared using human cadaver in bilateral cervical facet dislocation. The purpose of this study is to compare the stability of ACDFP, a posterior wiring procedure after ACDFP(ACDFPW), and ACDFTP for treatment of bilateral cervical facet dislocation. Methods: Ten human spines (C3-T1) were tested in the following sequence: the intact state, after ACDFP(Group 1), ACDFPW(Group 2), and ACDFTP(Group 3). Intervertebral motions were measured by a video-based motion capture system. The range of motion(ROM) and neutral zone(NZ) were compared for each loading mode to a maximum of 2.0Nm. Results: ROMs for Group 1 were below that of the intact spine in all loading modes, with statistical significance in flexion and extension, but NZs were decreased in flexion and extension and slightly increased in bending and axial rotation without significances. Group 2 produced additional stability in axial rotation of ROM and in flexion of NZ than Group 1 with significance. Group 3 provided better stability than Group 1 in bending and axial rotation, and better stability than Group 2 in bending of both ROM and NZ. There was no significant difference in extension modes for the three Groups. Conclusion: ACDFTP(Group 3) demonstrates the most effective stabilization followed by ACDFPW(Group 2), and ACDFP(Group 1). ACDFP provides sufficient strength in most loading modes, ACDFP can provide an effective stabilization for bilateral cervical facet dislocation with a brace.

The Change of Motion Ranges of Adjacent Vertebral Joints after Lumbar Fusion Operation (요추 고정수술 후 인접척추 운동범위의 변화)

  • Yeo, Sang-Jun;Park, Seung-Won;Kim, Young-Baeg;Hwang, Sung-Nam;Choi, Duck-Young;Suk, Jong-Sik;Chung, Dong-Kue;Min, Byung-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1456-1460
    • /
    • 2000
  • Objectives : Transpedicular screw fixation has become an important method for internal fixation in variety of disorders. However, acceleration of degeneration at the adjacent segment in any follow. The goal of this study is to review the change of motion ranges of vertebral joints adjacent to fused level in lumbar spine. Methods : This study consists of 22 patients with degenerative spinal instability. Treatment of spinal instability includes posterior fusion with transpedicular screw fixation or transpedicular screw fixation with posterior lumbar interbody fusion. The flexion-extension angle(FEA) was measured from dynamic views of lumbar spine taken both at preoperative and post operative period. Results : The FEA of upper vertebral joint adjacent(FEA-u) to a fused L4-5 level was increased(p=0.010). The FEA-u was increased in case of L5-S1 fusion(p=0.025). The change of FEA-u in case of L5-S1 fusion was greater than that in L4-5 fusion(p=0.013). Conclusion : After L4-5 fusion, there seems to be more meaningful increase in FEA of L3-4 than that of L5-S1. The reason may be due to the damage of L3-4 facet joints during the operation, the other possible explanation may be the anatomical stability of L5-S1 vertebral joint. The change of FEA-u of L5-S1 fusion is increased more than that of L4-5 fusion. Because there are compensations in the adjacent vertebrae both above and below the fused L4-5, the compensatory motion in FEA-u of L5-S1 fusion was greater than that of the L4-5 fusion.

  • PDF

Minimally Invasive Multi-Level Posterior Lumbar Interbody Fusion Using a Percutaneously Inserted Spinal Fixation System : Technical Tips, Surgical Outcomes

  • Kim, Hyeun-Sung;Park, Keun-Ho;Ju, Chag-Il;Kim, Seok-Won;Lee, Seung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.5
    • /
    • pp.441-445
    • /
    • 2011
  • Objective : There are technical limitations of multi-level posterior pedicle screw fixation performed by the percutaneous technique. The purpose of this study was to describe the surgical technique and outcome of minimally invasive multi-level posterior lumbar interbody fusion (PLIF) and to determine its efficacy. Methods : Forty-two patients who underwent mini-open PLIF using the percutaneous screw fixation system were studied. The mean age of the patients was 59.1 (range, 23 to 78 years). Two levels were involved in 32 cases and three levels in 10 cases. The clinical outcome was assessed using the visual analog scale (VAS) and Low Back Outcome Score (LBOS). Achievement of radiological fusion, intra-operative blood loss, the midline surgical scar and procedure related complications were also analyzed. Results : The mean follow-up period was 25.3 months. The mean LBOS prior to surgery was 34.5, which was improved to 49.1 at the final follow up. The mean pain score (VAS) prior to surgery was 7.5 and it was decreased to 2.9 at the last follow up. The mean estimated blood loss was 238 mL (140-350) for the two level procedures and 387 mL (278-458) for three levels. The midline surgical scar was 6.27 cm for two levels and 8.25 cm for three level procedures. Complications included two cases of asymptomatic medial penetration of the pedicle border. However, there were no signs of neurological deterioration or fusion failure. Conclusion : Multi-level, minimally invasive PLIF can be performed effectively using the percutaneous transpedicular screw fixation system. It can be an alternative to the traditional open procedures.

Surgical Results of Patients with Isthmic Spondylolisthesis with Transpedicular Screw Fixation and Posterior Lumbar Interbody Fusion Using Posterior Movable Segment (협부형 척추전방전위증에 대한 후방가동관절 이용한 골유합술 및 척추경나사못 고정술의 수술적 결과)

  • Kim, Chan;Lee, Seung Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.108-114
    • /
    • 2001
  • Objective : Posterior lumbar interbody fusion(PLIF) provides the favorable outcome to degenerative lumbar disease, especially isthmic spondylolisthesis. To determine the long-term effect of PLIF using psterior movable segment, we analysed the results of follow-up radiologic changes and surgical outcome retrospectively Patients and Method : During the past 11 years(1989. 1.-1999. 9.), 148 patients with symptomatic lumbar spondylolisthesis were managed at our department and the clinical wants were throughly recieved and final outcome is determined at last follow up. PLIF using antogenous bone(posterior movable segment, iliac bone and rib) were performed in 106 case. Results : After an average follow-up period of 33 months(range ; 15-58 months), the results were excellent in 66 cases, good in 37 cases, fair in 2 cases and poor in 1 cases. And the satisfactory results were 103 cases(98.2%) in PLIF,. Conclusion : In conclusion, patients who underwent PLIF with autologous bone graft had good clinical and radiological outcomes without significant neurological complications.

  • PDF

Posterior Interspinous Fusion Device for One-Level Fusion in Degenerative Lumbar Spine Disease : Comparison with Pedicle Screw Fixation - Preliminary Report of at Least One Year Follow Up

  • Kim, Ho Jung;Bak, Koang Hum;Chun, Hyoung Joon;Oh, Suck Jun;Kang, Tae Hoon;Yang, Moon Sool
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.359-364
    • /
    • 2012
  • Objective : Transpedicular screw fixation has some disadvantages such as postoperative back pain through wide muscle dissection, long operative time, and cephalad adjacent segmental degeneration (ASD). The purposes of this study are investigation and comparison of radiological and clinical results between interspinous fusion device (IFD) and pedicle screw. Methods : From Jan. 2008 to Aug. 2009, 40 patients underwent spinal fusion with IFD combined with posterior lumbar interbody fusion (PLIF). In same study period, 36 patients underwent spinal fusion with pedicle screw fixation as control group. Dynamic lateral radiographs, visual analogue scale (VAS), and Korean version of the Oswestry disability index (K-ODI) scores were evaluated in both groups. Results : The lumbar spine diseases in the IFD group were as followings; spinal stenosis in 26, degenerative spondylolisthesis in 12, and intervertebral disc herniation in 2. The mean follow up period was 14.24 months (range; 12 to 22 months) in the IFD group and 18.3 months (range; 12 to 28 months) in pedicle screw group. The mean VAS scores was preoperatively $7.16{\pm}2.1$ and $8.03{\pm}2.3$ in the IFD and pedicle screw groups, respectively, and improved postoperatively to $1.3{\pm}2.9$ and $1.2{\pm}3.2$ in 1-year follow ups (p<0.05). The K-ODI was decreased significantly in an equal amount in both groups one year postoperatively (p<0.05). The statistics revealed a higher incidence of ASD in pedicle screw group than the IFD group (p=0.029) Conclusion : Posterior IFD has several advantages over the pedicle screw fixation in terms of skin incision, muscle dissection and short operative time and less intraoperative estimated blood loss. The IFD with PLIF may be a favorable technique to replace the pedicle screw fixation in selective case.

Posterior Transvertebral Extension Osteotomy - A Case Report - (후방 추체 경유 신전 절골술 - 증 례 보 고 -)

  • Jung, Ho;Kim, Yong-Seog;Park, Moon-Sun;Ha, Ho-Gyun;Lee, Jong-Sun;Kim, Ju-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1262-1266
    • /
    • 2000
  • Objective : Flat back syndrome constitutes a syndrome complex characterized by the loss of normal lumbar lordosis. Various techniques of correction for flat back syndrome have been reported. Posterior extension osteotomy has certain drawbacks. Forceful hyperextension of the spine may result in vascular complications such as rupture of the aorta or the inferior vena cava and stretching of superior mesenteric artery, and pseudoarthrosis. We describe a rationale and technique of transvertebral posterior extension osteotomy to avoid complications of posterior extension osteotomy and to achieve an correction of 30 degrees of flat back syndrome. Method : A 63-year-old woman with degenerative lumbar kyphosis presented with low back pain, thigh pain, knee pain and walking difficulty. Transpedicular fixation from L1 vertebra to S1 vertebra was accomplished for lumbar degenerative kyphosis. After 6 months, the patient presented with flat back syndrome. A second operation was performed with transvertebral posterior extension osteotomy. Result : With short segemental fusion, early bone fusion and correction of 30 degrees were achieved. Conclusion : Transvertebral posterior extension osteotomy provide an 30-60 degrees of correction of flat back syndrome. This technique is considered to be good method for the revision of lumbar degenerative kyphosis.

  • PDF

Targeting a Safe Entry Point for C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability

  • Chun, Hyoung-Joon;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.351-354
    • /
    • 2011
  • Objective : This investigation was conducted to evaluate a new, safe entry point for the C2 pedicle screw, determined using the anatomical landmarks of the C2 lateral mass, the lamina, and the isthmus of the pars interarticularis. Methods : Fifteen patients underwent bilateral C1 lateral mass-C2 pedicle screw fixation, combined with posterior wiring. The C2 pedicle screw was inserted at the entry point determined using the following method : 4 mm lateral to and 4 mm inferior to the transitional point (from the superior end line of the lamina to the isthmus of the pars interarticularis). After a small hole was made with a high-speed drill, the taper was inserted with a 30 degree convergence in the cephalad direction. Other surgical procedures were performed according to Harm's description. Preoperatively, careful evaluation was performed with a cervical X-ray for C1-C2 alignment, magnetic resonance imaging for spinal cord and ligamentous structures, and a contrast-enhanced 3-dimensional computed tomogram (3-D CT) for bony anatomy and the course of the vertebral artery. A 3-D CT was checked postoperatively to evaluate screw placement Results : Bone fusion was achieved in all 15 patients (100%) without screw violation into the spinal canal, vertebral artery injury, or hardware failure. Occipital neuralgia developed in one patient, but this subsided after a C2 ganglion block. Conclusion : C2 transpedicular screw fixation can be easily and safely performed using the entry point of the present study. However, careful preoperative radiographic evaluation, regardless of methods, is mandatory.

Collapsed L4 Vertebral Body Caused by Brucellosis

  • Ekici, Mehmet Ali;Ozbek, Zuhtu;Kazanci, Burak;Guclu, Bulent
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.48-50
    • /
    • 2014
  • Brucellosis is caused by gram-negative, aerobic, non-motile, facultative, intracellular coccobacilli belonging to the genus Brucella. A 50-year-old man working as an employee was admitted to neurosurgery clinic with severe low back, radicular right leg pain and hypoesthesia in right L4-5 dermatomes for 2 months. Brucella tube agglutination (Wright) test was positive in serum sample of the patient with a titer of 1/640. Brucella melitensis was isolated from blood culture. X-ray and MRI of the lomber spine showed massive collapse of L4 vertebral body. Neural tissue was decompressed and then posterior L3-5 short segment transpedicular screw fixation and stabilization was performed. Brucella melitensis was isolated from microbiologic culture of pathologic specimen. Antibiotic therapy was given as doxycycline 200 mg/day and rifampicin 600 mg/day for 6 months. Brucellosis is a systemic zoonotic infection and still an important public health problem in many geographical parts of the world. Vertebral body collapse caused by brucellosis occurs very rarely but represents a neurosurgical emergency because of its potential for causing rapidly progressive spinal cord compression and permanent paralysis. Neurosurgeons, emergency department personnel as well as infectious disease specialists should always keep a high index of suspicion and include brucellosis in the differential diagnosis of vertebral body collapse.

Effects of Screw Diameter and Thread Shape on the Strength of Transpedicular Screw Fixation in Posterior Spinal Fusion (후방 척추고정술에서 척추경 나사못의 크기와 형태가 척추 고정력에 미치는 영향에 대한 연구)

  • Mun, Mu-S.;Ryu, Jei-C.;Yoo, Myung-C.;Kim, Ki-T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.23-26
    • /
    • 1995
  • The objectives of the present study are 1)to find the effect of the diameter of transpedicular screws on their fixational strength in pedicles under static pull-out loading, 2)to determine the biomechanical correlation between the pedicle diameter and the screw diameter, and 3)to find the effects of other factors in the screw design, such as materials, screw pitch, thread height and shape on their fixational strength. Biomechanical tests (Test I) were performed to evaluate the effect of the screw diameter on pull-out strength by using 60 porcine pedicls and six groups of custom-made pedicle screws with different diameters (the major and the minor diameter of the screws used in the testing varied from 4mm upto 9mm and from 3mm upto 8mm, respectively) while all other factors (materials, screw pitch, thread height and shape etc.) were fixed. In Test II, by using 61 porcine pedicles, the relationship between the ratio of the pedicle diameter and the screw diameter(=aspect ratio) of the custum-made screw and the pull-out strength of the screw was investigated. Test III was performed with 94 porcine pedicles and 8 different types of the commercial screws from 6 major productors in order to determine the effect of the screw diameter, pitch and the thread shape on the pull-out strength of the screw, respectively. The results of Test I showed that the axial pull-out resistance of the screw could be increased prportionaly to the screw diameter(P<0.05). But this increase in the pull-out resistance did not found when the screws of 4mm or 9mm in the diameter were employed. It was found from the results of Test II that the screws had its maximum pull-out resistant force when the aspect ratio ranging 40 - 69% (P<0.05). based on the results for the major diameter against the minor diameter of screw, the maximal pull-out resistance was found at 60-65% (P<0.05). According to these biomechanical testing results, it seems that the screw with a moderately large pitch is more desirable and the buttress-shaped screw can provide stronger fixation than the V-shape one can, if other designal factor and conditions were fixed.

  • PDF