Browse > Article
http://dx.doi.org/10.3340/jkns.2012.52.4.359

Posterior Interspinous Fusion Device for One-Level Fusion in Degenerative Lumbar Spine Disease : Comparison with Pedicle Screw Fixation - Preliminary Report of at Least One Year Follow Up  

Kim, Ho Jung (Department of Neurosurgery, Hanyang University College of Medicine, Seoul Hospital)
Bak, Koang Hum (Department of Neurosurgery, Hanyang University College of Medicine, Seoul Hospital)
Chun, Hyoung Joon (Department of Neurosurgery, Hanyang University College of Medicine, Seoul Hospital)
Oh, Suck Jun (Department of Neurosurgery, Hanyang University College of Medicine, Seoul Hospital)
Kang, Tae Hoon (Department of Neurosurgery, Hanyang University College of Medicine, Guri Hospital)
Yang, Moon Sool (Department of Neurosurgery, Namyangju Woori Hospital)
Publication Information
Journal of Korean Neurosurgical Society / v.52, no.4, 2012 , pp. 359-364 More about this Journal
Abstract
Objective : Transpedicular screw fixation has some disadvantages such as postoperative back pain through wide muscle dissection, long operative time, and cephalad adjacent segmental degeneration (ASD). The purposes of this study are investigation and comparison of radiological and clinical results between interspinous fusion device (IFD) and pedicle screw. Methods : From Jan. 2008 to Aug. 2009, 40 patients underwent spinal fusion with IFD combined with posterior lumbar interbody fusion (PLIF). In same study period, 36 patients underwent spinal fusion with pedicle screw fixation as control group. Dynamic lateral radiographs, visual analogue scale (VAS), and Korean version of the Oswestry disability index (K-ODI) scores were evaluated in both groups. Results : The lumbar spine diseases in the IFD group were as followings; spinal stenosis in 26, degenerative spondylolisthesis in 12, and intervertebral disc herniation in 2. The mean follow up period was 14.24 months (range; 12 to 22 months) in the IFD group and 18.3 months (range; 12 to 28 months) in pedicle screw group. The mean VAS scores was preoperatively $7.16{\pm}2.1$ and $8.03{\pm}2.3$ in the IFD and pedicle screw groups, respectively, and improved postoperatively to $1.3{\pm}2.9$ and $1.2{\pm}3.2$ in 1-year follow ups (p<0.05). The K-ODI was decreased significantly in an equal amount in both groups one year postoperatively (p<0.05). The statistics revealed a higher incidence of ASD in pedicle screw group than the IFD group (p=0.029) Conclusion : Posterior IFD has several advantages over the pedicle screw fixation in terms of skin incision, muscle dissection and short operative time and less intraoperative estimated blood loss. The IFD with PLIF may be a favorable technique to replace the pedicle screw fixation in selective case.
Keywords
Degenerative; Fusion device; Interspinous; Lumbar disease; Posterior; Adjacent segmental degeneration;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
연도 인용수 순위
  • Reference
1 Lee CK, Langrana NA : Lumbosacral spinal fusion. A biomechanical study. Spine (Phila Pa 1976) 9 : 574-581, 1984   DOI   ScienceOn
2 Papp T, Porter RW, Aspden RM, Shepperd JA : An in vitro study of the biomechanical effects of flexible stabilization on the lumbar spine. Spine (Phila Pa 1976) 22 : 151-155, 1997   DOI   ScienceOn
3 Park P, Garton HJ, Gala VC, Hoff JT, McGillicuddy JE : Adjacent segment disease after lumbar or lumbosacral fusion : review of the literature. Spine (Phila Pa 1976) 29 : 1938-1944, 2004   DOI   ScienceOn
4 Schlegel JD, Smith JA, Schleusener RL : Lumbar motion segment pathology adjacent to thoracolumbar, lumbar, and lumbosacral fusions. Spine (Phila Pa 1976) 21 : 970-981, 1996   DOI   ScienceOn
5 Schnake KJ, Schaeren S, Jeanneret B : Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine (Phila Pa 1976) 31 : 442-449, 2006   DOI   ScienceOn
6 Schulte TL, Leistra F, Bullmann V, Osada N, Vieth V, Marquardt B, et al. : Disc height reduction in adjacent segments and clinical outcome 10 years after lumbar 360 degrees fusion. Eur Spine J 16 : 2152-2158, 2007   DOI   ScienceOn
7 Sonntag VK, Marciano FF : Role of spinal instrumentation in fusion for degenerative disease of the lumbosacral spine. West J Med 162 : 262- 263, 1995
8 Thomsen K, Christensen FB, Eiskjaer SP, Hansen ES, Fruensgaard S, Bünger CE : 1997 Volvo Award winner in clinical studies. The effect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion : a prospective, randomized clinical study. Spine (Phila Pa 1976) 22 : 2813-2822, 1997   DOI   ScienceOn
9 Wang JC, Haid RW Jr, Miller JS, Robinson JC : Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005. J Neurosurg Spine 4 : 132-136, 2006   DOI   ScienceOn
10 Wang JC, Spenciner D, Robinson JC : SPIRE spinous process stabilization plate : biomechanical evaluation of a novel technology. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005. J Neurosurg Spine 4 : 160-164, 2006   DOI   ScienceOn
11 West JL 3rd, Ogilvie JW, Bradford DS : Complications of the variable screw plate pedicle screw fixation. Spine (Phila Pa 1976) 16 : 576-579, 1991   DOI   ScienceOn
12 Zdelblick TA : A prospective, randomized study of lumbar fusion. Preliminary results. Spine (Phila Pa 1976) 18 : 983-991, 1993   DOI   ScienceOn
13 Bridwell KH, Sedgewick TA, O'Brien MF, Lenke LG, Baldus C : The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis. J Spinal Disord 6 : 461-472, 1993   DOI   ScienceOn
14 Esses SI, Sachs BL, Dreyzin V : Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine (Phila Pa 1976) 18 : 2231-2238; discussion 2239, 1993   DOI   ScienceOn
15 Cardoso MJ, Dmitriev AE, Helgeson M, Lehman RA, Kuklo TR, Rosner MK : Does superior-segment facet violation or laminectomy destabilize the adjacent level in lumbar transpedicular fixation? An in vitro human cadaveric assessment. Spine (Phila Pa 1976) 33 : 2868-2873, 2008   DOI   ScienceOn
16 Cunningham BW, Kotani Y, McNulty PS, Cappuccino A, McAfee PC : The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure : an in vitro biomechanical analysis. Spine (Phila Pa 1976) 22 : 2655-2663, 1997   DOI   ScienceOn
17 Dickman CA, Fessler RG, MacMillan M, Haid RW : Transpedicular screw-rod fixation of the lumbar spine : operative technique and outcome in 104 cases. J Neurosurg 77 : 860-870, 1992   DOI
18 Fischgrund JS, Mackay M, Herkowitz HN, Brower R, Montgomery DM, Kurz LT : 1997 Volvo Award winner in clinical studies. Degenerative lumbar spondylolisthesis with spinal stenosis : a prospective, randomized study comparing decompressive laminectomy and arthrodesis with and without spinal instrumentation. Spine (Phila Pa 1976) 22 : 2807-2812, 1997   DOI   ScienceOn
19 Ghiselli G, Wang JC, Hsu WK, Dawson EG : L5-S1 segment survivorship and clinical outcome analysis after L4-L5 isolated fusion. Spine (Phila Pa 1976) 12 : 1275-1280; discussion 1280, 2003
20 Hilibrand AS, Robbins M : Adjacent segment degeneration and adjacent segment disease : the consequences of spinal fusion? Spine J 4 :190S-194S, 2004   DOI   ScienceOn
21 Jutte PC, Castelein RM : Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11 : 594-598, 2002   DOI   ScienceOn
22 Lafage V, Gangnet N, Sénégas J, Lavaste F, Skalli W : New interspinous implant evaluation using an in vitro biomechanical study combined with a finite-element analysis. Spine (Phila Pa 1976) 32 : 1706-1713, 2007   DOI   ScienceOn
23 Karahalios DG, Kaibara T, Porter RW, Kakarla UK, Reyes PM, Baaj AA, et al. : Biomechanics of a lumbar interspinous anchor with anterior lumbar interbody fusion. J Neurosurg Spine 12 : 372-380, 2010   DOI   ScienceOn