• Title/Summary/Keyword: Post hoc

Search Result 1,290, Processing Time 0.034 seconds

Effect of hemispherical dimples at titanium implant abutments for the retention of cemented crowns

  • Jung-Hoon Choi;Seong-Joo Heo;Jai-Young Koak;Seong-Kyun Kim;Ji-Man Park;Jin-Soo Ahn
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.2
    • /
    • pp.63-71
    • /
    • 2023
  • PURPOSE. The aim of this study was to assess the effect of hemispherical dimple structures on the retention of cobalt-chromium (Co-Cr) crowns cemented to titanium abutments, with different heights and numbers of dimples on the axial walls. MATERIALS AND METHODS. 3.0-mm and 6.0-mm abutments (N = 180) and Co-Cr crowns were prepared. The experimental groups were divided into two and four dimple groups. The crowns were cemented by TempBond and PANAVIA F 2.0 cements. The retention forces were measured after thermal treatments. A two-way Analysis of Variance (ANOVA) and post-hoc Tukey HSD test were conducted to analyze change in retention forces by use of dimples between groups, as well as t test for the effect of abutment height change (α = .05). RESULTS. Results of the two-way ANOVA showed a statistically significant difference in retention force due to the use of dimples, regardless of the types of cements used (P < .001). A significantly higher mean retention forces were observed in the groups with dimples than in the control group, using the post hoc Tukey HSD test (P < .001). Results of t test displayed a statistically significant increase in the retention force with 6.0-mm abutments compared with 3.0-mm abutments (P < .001). The groups without dimples revealed adhesive failure of cements, while the groups with dimples showed mixed failure of cements. CONCLUSION. Use of hemispherical dimples was effective for increasing retention forces of cemented crowns.

The Latest Trends in Attention Mechanisms and Their Application in Medical Imaging (어텐션 기법 및 의료 영상에의 적용에 관한 최신 동향)

  • Hyungseob Shin;Jeongryong Lee;Taejoon Eo;Yohan Jun;Sewon Kim;Dosik Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1305-1333
    • /
    • 2020
  • Deep learning has recently achieved remarkable results in the field of medical imaging. However, as a deep learning network becomes deeper to improve its performance, it becomes more difficult to interpret the processes within. This can especially be a critical problem in medical fields where diagnostic decisions are directly related to a patient's survival. In order to solve this, explainable artificial intelligence techniques are being widely studied, and an attention mechanism was developed as part of this approach. In this paper, attention techniques are divided into two types: post hoc attention, which aims to analyze a network that has already been trained, and trainable attention, which further improves network performance. Detailed comparisons of each method, examples of applications in medical imaging, and future perspectives will be covered.

Comparative Study on the Effects of Two Taping Methods Applied to Patients with Low Back Pain (요통을 가지고 있는 일반인에게 적용된 두 가지 테이핑 방법의 효과 비교 연구)

  • Il-Young Cho
    • Journal of Industrial Convergence
    • /
    • v.22 no.7
    • /
    • pp.43-48
    • /
    • 2024
  • In this study, we evaluated the effectiveness of a taping method to relieve low back pain (LBP) by comparing changes in visual analog scale (VAS) and disability index (Disa) between untreated, control, and treated groups. As a result, the efficacy of taping was confirmed in both the control and treatment groups. ANOVA analysis of VAS revealed significant differences between groups, and post hoc tests revealed significant differences in the untreated group and both the control and treatment groups, but no significant differences between the control and treatment groups. This demonstrates similar effectiveness of both taping methods on alleviating LBP. For Disa, ANOVA showed a significant difference, but post hoc tests did not confirm this. The within-group t-test showed significant differences in VAS and Disa in the control and treatment groups before and after the intervention, but not in the untreated group. This study highlights the efficacy of taping for LBP and suggests that both methods can be used clinically. Future studies should use larger samples and different conditions to verify these findings.

Self-care, Social Support, and Biological Markers in Liver Transplant Recipients (간이식 수혜자의 자가간호이행, 사회적 지지, 생리학적 지표)

  • Kim, Hyunkyung;Choi, Mona;Kim, So Sun;Kim, Soon-Il
    • Korean Journal of Adult Nursing
    • /
    • v.27 no.2
    • /
    • pp.170-179
    • /
    • 2015
  • Purpose: To examine the relationships between self-care, social support, and biological markers in liver transplant recipients. Methods: The participants included 118 liver transplant recipients who visited outpatient clinic at Y University Hospital in Seoul from April to May, 2013. Questionnaires consisted of self-care and social support scales. The biological markers were collected by reviewing electronic medical records. Data were analyzed with descriptive statistics, t-test, ANOVA with Scheff$\acute{e}$ post-hoc test, and Pearson's correlation. Results: The self-care score was significantly higher in a patient group within 6 months post-transplant when compared to a patient group post-transplant 3 to 5 years (F=3.10, p=.018). The self-care showed positive correlation with social support with statistical significance (r=.36, p<.001). Conclusion: As the self-care in liver transplant recipients had a positive correlation with social support from family and healthcare providers, the development of comprehensive long-term nursing intervention systems including counseling, education, and support in consideration of progress of time period after transplantation is necessary to enhance self-care behaviors among this population.

Comparison the Initial Effects of Nerve Mobilization Techniques, Static Stretching and Contract-Relax on Hamstring Flexibility and Walking Ability in Post-Stroke Hemiplegia Patients (뇌졸중으로 인한 편마비 환자의 슬괵근 유연성과 보행능력에 대한 신경가동기법, 정적 신장기법 및 수축-이완기법의 즉각적 효과 비교)

  • Kim, Yong-Jeong;Kim, Taek-Yean;Kim, Suhn-Yeop;Oh, Duck-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.369-379
    • /
    • 2011
  • Purpose : The purpose of this study is to compare the initial effect of nerve mobilization (NM), static stretching (SS), and contract-relax (CR) techniques to find the best method in improving hamstring flexibility and gait function in patients with hemiplegia. Methods : Eleven patients with hemiplegia were included in this study. Passive knee extension (PKE) range of motion and the sit and reach (SR) test were used to measure hamstring flexibility, while timed up and go (TUG) and the 10m walking (10MW) test were used to measure the subject's gait. Measurements on each test were assessed prior to the experiment, immediately following the experiment, and 30 minutes after the experiment. Analysis of the results utilized a repeated measures analysis of variance to examine hamstring flexibility and the difference in walking ability. Results : The results suggest significant increases in NM, SS, and CR techniques as they relate to hamstring flexibility (p<.05) following (both immediate and 30 minutes post experiment) PKE range of motion and the SR test, but post-hoc showed no significant difference between the three techniques (p>.05). Additionally, the results suggest significant increases in NM, SS, and CR techniques as they relate to gait function (p<.05) following the TUG test, but found no significant difference in the 10MW test (p>.05). Post-hoc analysis between the three techniques suggests that only the NM technique significantly changed gait function. The time of TUG and 10MW test showed no significant difference between the three techniques before an experiment, just after an experiment, and 30 minutes following the experiment according to the measurement points in time (p>.05). Conclusion : This study suggests NM, SS, and CR techniques immediately improve hamstring length and flexibility while improving gait function in patients with hemiplegia.

A Study of Job Stress and Turnover Intention related to Transfer of Duty Post of Staff Nurses in the General Hospitals (종합병원 일반 간호사의 근무지 이동과 관련된 직무 스트레스 및 이직의도)

  • Kwon, Deok-Wha;Koh, Hyo-Jung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.9 no.1
    • /
    • pp.141-150
    • /
    • 2003
  • Purposes : This study was to investigate the job stress and turnover intention related to transfer of duty post of staff nurses working in general hospitals. Method : The subjects of this study were 384 staff nurses working in 6 general hospitals, with more than 200 beds, in Daegu and Kungbuk province in Korea. Data were collected through questionnaires and from Sep. 15 to Oct. 6, 2001. The used tool for measuring the degree of job stress was developed by Kim and Gu(1984) and the used tool for measuring the degree of turnover intention was developed Kim and Lee(2001). The data were analyzed into frequency, percentage, mean, standard deviation, t-test, ANOVA, Tukey's post hoc contrast, Pearson's correlation coefficient according to the purpose of study by use SPSS Win 10.0 statistical program. Results : The following are the results of the study: (1) Average score of the job stress, turnover intention of resignation of the subjects were 2.64 and 4.44. (2) The result of the analysis of job stress related to transfer of duty post was higher in job stress; not satisfaction of current duty post(t=-2.06, p=0.04). (3) The result of the analysis of turnover intention related to transfer of duty post was higher in turnover intention; period of the an advance notice when transfer to current duty post less than 7day(F=3.55, p=0.02), not satisfaction of current duty post(t=-2.45, p=0.02), want the transfer from current duty post(t=3.68, p=0.00). (4) The study reveals that there was statistically significant positive correlation relationship between job stress factors and turnover intention(r=.183, p=.000). Conclusion : The study which relating to period of the an advance when transfer and satisfaction of current duty post and reconsideration of transfer of duty post shows statistically significant difference between job stress and turnover intention. Therefore it is regarded that is needed to set a period of profer advance notice, grip on unsatisfactory factor of current duty post and intervention and management of the subjects were wanted transfer of duty post.

  • PDF

The effects of non-thermal plasma and conventional treatments on the bond strength of fiber posts to resin cement

  • do Prado, Maira;da Silva, Eduardo Moreira;Marques, Juliana das Neves;Gonzalez, Caroline Brum;Simao, Renata Antoun
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.125-133
    • /
    • 2017
  • Objectives: This study compared the effect of hexamethyldisiloxane (HMDSO) and ammonia ($NH_3$) plasmas on the bond strength of resin cement to fiber posts with conventional treatments. Materials and Methods: Sixty-five fiber posts were divided into 5 groups: Control (no surface treatment); $H_2O_2$ (24% hydrogen peroxide for 1 min); Blasting (blasting with aluminum oxide for 30 sec); $NH_3$ ($NH_3$ plasma treatment for 3 min); HMDSO (HMDSO plasma treatment for 15 min). After the treatments, the Ambar adhesive (FGM Dental Products) was applied to the post surface (n = 10). The fiber post was inserted into a silicon matrix that was filled with the conventional resin cement Allcem Core (FGM). Afterwards, the post/cement specimens were cut into discs and subjected to a push-out bond strength (POBS) test. Additionally, 3 posts in each group were evaluated using scanning electron microscopy. The POBS data were analyzed by one-way analysis of variance and the Tukey's honest significant difference post hoc test (${\alpha}=0.05$). Results: The Blasting and $NH_3$ groups showed the highest POBS values. The HMDSO group showed intermediate POBS values, whereas the Control and $H_2O_2$ groups showed the lowest POBS values. Conclusion: Blasting and $NH_3$ plasma treatments were associated with stronger bonding of the conventional resin cement Allcem to fiber posts, in a procedure in which the Ambar adhesive was used.

Effect of antioxidants on push-out bond strength of hydrogen peroxide treated glass fiber posts bonded with two types of resin cement

  • Khoroushi, Maryam;Mazaheri, Hamid;Tarighi, Pardis;Samimi, Pouran;Khalighinejad, Navid
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.303-309
    • /
    • 2014
  • Objectives: Hydrogen peroxide ($H_2O_2$) surface treatment of fiber posts has been reported to increase bond strength of fiber posts to resin cements. However, residual oxygen radicals might jeopardize the bonding procedure. This study examined the effect of three antioxidant agents on the bond strength of fiber posts to conventional and self-adhesive resin cements. Materials and Methods: Post spaces were prepared in forty human maxillary second premolars. Posts were divided into five groups of 8 each: G1 (control), no pre-treatment; G2, 10% $H_2O_2$ pre-treatment; G3, G4 and G5. After $H_2O_2$ application, Hesperidin (HES), Sodium Ascorbate (SA) or Rosmarinic acid (RA) was applied on each group respectively. In each group four posts were cemented with Duo-Link conventional resin cement and the others with self-adhesive BisCem cement. Push-out test was performed and data were analyzed using 2-way ANOVA and tukey's post-hoc test (${\alpha}=0.05$). Results: There was a statistically significant interaction between the cement type and post surface treatment on push-out bond strength of fiber posts (p < 0.001, F = 16). Also it was shown that different posts' surface treatments significantly affect the push-out bond strength of fiber posts (p = 0.001). $H_2O_2$ treated posts (G2) and control posts (G1) cemented with Duo-link showed the highest ($15.96{\pm}5.07MPa$) and lowest bond strengths ($6.79{\pm}3.94$) respectively. Conclusions: It was concluded that $H_2O_2$ surface treatment might enhance the bond strength of fiber posts cemented with conventional resin cements. The effect of antioxidants as post's surface treatment agents depends on the characteristics of resin cements used for bonding procedure.

Dietary guidelines adherence and changes in eating habits among college students in the post-COVID-19 period: a cross-sectional study (코로나 이후 대학생의 배달음식 간편식 외식 및 식생활 행태 변화와 식생활지침 실천 정도에 대한 단면조사연구)

  • Eunyoung Yoon
    • Korean Journal of Community Nutrition
    • /
    • v.28 no.3
    • /
    • pp.220-234
    • /
    • 2023
  • Objectives: This study aimed to assess the adherence to dietary guidelines among college students in the post-COVID-19 era and examine the changes in their dietary habits as the learning environment transitioned from remote to in-person classes. Methods: We conducted a survey involving 327 college students in Daejeon from March to April 2023. The survey questionnaires included various factors, including age, gender, type of residence, frequency of use of delivery food, convenience food, and eating out. In addition, we investigated the extent of adherence to the dietary guidelines for Koreans and the degree of dietary changes following the post-COVID-19 shift in class format were investigated. For comparative analysis of the level of adherence to dietary guidelines in relation to dietary habit changes, an ANOVA and a post hoc Scheffe test were employed. We also performed a multiple linear regression analysis to identify dietary factors influencing the level of adherence to dietary guidelines. Results: The study revealed a high rate of convenience food consumption and a low rate of homemade food intake among students. There was a marked increase in the consumption of processed foods, convenience foods, dining out, sweet foods, high-fat fried foods, beverages, and alcohol following the transition from online to in-person classes. When examining adherence to Korean dietary guidelines, the highest scored practice was 'Hydration', and the lowest was 'Breakfast habit'. Increased consumption of convenience foods, late-night snacks, and dining out were negatively correlated with adherence levels to dietary guidelines, specifically correlating with 'Healthy weight', 'Hydration', 'Breakfast habit', and the total score of adherence. The adoption of 'regular meals' was positively associated with increased adherence levels to dietary guidelines. Conclusions: The transition from remote to in-person classes post-COVID-19 led to increased intake of convenience foods, dining out, sweet foods, high-fat fried foods, and alcohol. The rise in convenience food and late-night snack consumption negatively influenced several aspects of the dietary guidelines adherence, thereby suggesting the need for strategies to encourage healthy dietary habits among college students.

Influence of airborne-particle abrasion on flexural strength of fiber-reinforced composite post (미세입자 분사마모 표면처리가 Fiber-Reinforced Composite 포스트의 굴곡 강도에 미치는 영향)

  • Sim, Eun-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.24-31
    • /
    • 2016
  • Purpose: Many studies have shown that airborne-particle abrasion of fiber post can improve the bonding strength to resin cement. But, airborne-particle abrasion may influence the property of fiber post. The purpose of this study is to evaluate the influence of airborne-particle abrasion on flexural strength of fiber post. Materials and Methods: Two fiber-reinforced posts; DT Light Post Size 2 (1.8 mm diameter, Bisco Inc) and RelyX Fiber Post Size 3 (1.9 mm diameter, 3M ESPE); were used in this study. Each group was divided into 3 subgroups according to different surface treatments; without pretreatment: $50{\mu}m$ aluminum oxide (Cobra$^{(R)}$, Renfert): and $30{\mu}m$ aluminum oxide modified with silica (Rocatec Soft$^{(R)}$, 3M ESPE). After airborne-particle abrasion procedure, three-point bending test was done to determine the flexural strength and flexural modulus. The diameter of each posts was measured to an accuracy of 0.01 mm using a digital micrometer. There was no diameter change before and after airborneparticle abrasion. The mean flexural moduli and flexural strengths calculated using the appropriate equations. The results were statistically analyzed using One-way ANOVA and Scheffe's post-hoc test at 95% confidencial level. Results: There was no significant difference on flexural strength between groups. Conclusion: In the limitation of this study, flexural strength and flexural modulus of fiber post are not affected by airborne-particle abrasion.