• Title/Summary/Keyword: Post effect

Search Result 6,174, Processing Time 0.042 seconds

Distortional effect on global buckling and post-buckling behaviour of steel box beams

  • Benmohammed, Noureddine;Ziane, Noureddine;Meftah, Sid Ahmed;Ruta, Giuseppe
    • Steel and Composite Structures
    • /
    • v.35 no.6
    • /
    • pp.717-727
    • /
    • 2020
  • The homotopy perturbation method (HPM) to predict the pre- and post-buckling behaviour of simply supported steel beams with rectangular hollow section (RHS) is presented in this paper. The non-linear differential equations solved by HPM derive from a kinematics where large twist and cross-sections distortions are considered. The results (linear and non-linear paths) given by the present HPM are compared to those provided by the Newton-Raphson algorithm with arc length and by the commercial FEM code Abaqus. To investigate the effect of cross-sectional distortion of beams, some numerical examples are presented.

Prediction of Steady-state Strip Profile during Hot Rolling - PartⅠ: FEM Analysis (열연 공정 정상상태 판 프로파일 예측 - PartⅠ: 유한요소 해석)

  • Lee, J.S.;Hwang, S.M.
    • Transactions of Materials Processing
    • /
    • v.25 no.1
    • /
    • pp.56-60
    • /
    • 2016
  • Precise prediction and control of the strip profile is crucial for automatic process set-up and operation of a hot strip mill. In the current study, we present the effect of post-deformation on the steady-state strip profile. The process was simulated by a 3-D elastic-plastic finite element (FE) analysis. Comparisons are made between the strip profile measured at the roll exit and the steady-state strip profile. The results raised an issue with regard to the importance of taking into account the effect of post-deformation.

Effect of the Reinforcement Index on the Unbonded Tendon Stress of Post-tensioned Lightweight Concrete Beams (포스트텐션 경량콘크리트 보의 비부착 긴장재 응력에 대한 보강지수의 영향)

  • Mun, Ju-Hyun;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.89-90
    • /
    • 2010
  • Three post-tensioned lightweight concrete beams were tested to examine the effect of the reinforcement index on the unbonded tendon stress at ultimate strength of the beams. The reinforcement index selected for main variables were 0.06, 0.15, 0.30. Test results showed that the stress of the unbonded tendons in the ultimate strength of the post-tensioned lightweight concrete beams can be conservatively evaluated using the empirical equations specified in ACI 318-08.

  • PDF

A Electrochemical Study on the Effect of Post-Weld Heat Treatment about Corrosion Resistance Property of SS400 Steel for Ship's Materials (선박재료용 SS400강의 내식성에 대한 용접후열처리효과에 관한 전기화학적 연구(I))

  • 김진경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.806-813
    • /
    • 1999
  • The effect of Post-Weld Heat Treatment(PWHT) of SS400 Steel was investigated with parameters such as micro vickers hardness corrosion potential polarization behaviors galvanic current Al anode generating current Al anode weight loss etc. Hardness of each parts(HAZ, BM, WM)by PWHT is lower than that of each parts by Non Post-Weld Heat Treatment(NPWHT) However hardness of WM of HAZ part was the highest among those three parts and HAZ area were also acted as cathode without any case of heat treatment. Potential difference between each three parts by PWHT was also smaller compared to NPWHT. Therefore it is suggested that Corrosion resistance property is increased by PWHT. However both Al anode generating current and anode weight loss was also decreased by PWHT compared to NPWHT when SS400 steel is cathodically protected by Al anode.

  • PDF

The Effect of Static Balance Recovery by Open Kinetic Chain and Closed Kinetic Chain Exercises (열린 사슬 운동과 닫힌 사슬 운동이 정적균형 능력에 미치는 영향)

  • Kwon, Yoo-Jung;Bae, Sung-Soo;Park, Soo-Jin
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • Purpose : This study was investigated the effect of static balance recovery during open kinetic chain exercise (OKC) and closed kinetic chain exercise(CKC). Methods : The paticipants were consisted of forty-one, was perform 3 sets, 3 times per week for 6 weeks, balance was measured by GOOD BALANCE. Statistical analysis was used repeated measure two-way ANOVA and independent t-test. Results : In CKC group, Center of presure(COP) medial-lateral(ML) velocity was significantly increased post 6 week test than pre-test, post 2 week test. COP anterior-posterior(AP) velocity was significantly increased post 6 week test than pre-test (p<.05). Conclusion : It was found that both OKC and CKC was significantly increased balance recovery in normal younng adults. In further study, it was suggested that was regard patient with muscle weakness.

  • PDF

Post Sliced Cleaning of Silicon Wafers using Ozone and Ultrasound (오존과 초음파를 이용한 실리콘 웨이퍼의 Post Sliced Cleaning)

  • Choi, Eun-Suck;Bae, So-Ik
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.75-79
    • /
    • 2006
  • The effect of ozone and/or ultrasound treatments on the efficiency of slurry removal in post sliced cleaning (PSC) of silicon ingot was studied. Efficiency of slurry removal was evaluated as functions of time, temperature and surfactant with DOE (Design of Experiment) method. Residual slurries were observed on the wafer surface in case of cleaning by ozone or ultrasound separately. However, a clean wafer surface was appeared when cleaned with ozone and ultrasound simultaneously. It has found that cleaning time was the main effect among temperature, time and surfactant. Elevated temperature, addition of surfactant and high ozone concentration helped to accelerate efficient removal of slurry. The improvement of removal efficiency seems to be related to the formation of more active OH radicals. The highly cleaned surface was achieved at 10 wt% ozone, 1 min and 10 vol% surfactant with ultrasound. Application of ozone and ultrasound might be a useful method for PSC process in wafer cleaning.

Effect of Post Deposition Annealing Temperature on the Structural, Optical and Electrical Properties of GZO Films Prepared by RF Magnetron Sputtering (RF 마그네트론 스퍼터링으로 증착 된 GZO 박막의 진공 열처리온도에 따른 구조적, 광학적, 전기적 특성 연구)

  • Kim, Daeil
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.4
    • /
    • pp.199-202
    • /
    • 2011
  • Ga doped ZnO thin films were deposited with RF magnetron sputtering on glass substrate without intentional substrate heating and then the effect of post deposition annealing temperature on the structural, optical and electrical properties of the films was investigated. The post deposition annealing process was conducted for 30 minutes in a vacuum of $1{\times}10^{-3}$ Torr and the vacuum annealing temperatures were 150 and $300^{\circ}C$, respectively. As increase annealing temperature, GZO films show the increment of the prefer orientation of ZnO (002) diffraction peak in the XRD pattern and the optical transmittance in a visible wave region was also increased, while the electrical sheet resistance was decreased. The figure of merit obtained in this study means that GZO films which vacuum annealed at $300^{\circ}C$ have the highest optoelectrical performance in this study.

The Study of Curcuma Longs L. Dyeing (울금의 염색성에 관한 연구)

  • 주영주;소황옥
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.3
    • /
    • pp.429-437
    • /
    • 1996
  • This paper surveys extraction condition-temperature, pH, and changes of adsorbance in accordance with extraction condition of curcuma Longa L. solution. Using extracted curcuma Longa L. Solution, dyeing behaviors with natural fiber, effect of mordants to color fastness and color change were investigated. It was found that the amount of absorption (K/S value) was increased by mordants (Fe, Cr) and mordants treatment affected color change of dyed fabric. Among the mordants, effect of citric acid to color change of dyed fabric was the smallest, and color difference of post- mordant treatment is smaller than that of pee-mordant treatment in making use of citric acid as mordant. And K/S value of post mordant was higher than that of pre mordant. It was found that the pre - and post- mordants treatment little affected color fastness, but affected the amound of adsorption and color change of dyed fabric.

  • PDF

Cracking Analysis of RC Tension Members Using Polynomial Strain Distribution Function (다항식 변형률 분포함수를 이용한 철근콘크리트 인장부재의 균열해석)

  • 곽효경;송종영
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.267-274
    • /
    • 2001
  • In this paper, a analytical model which can simulate the post-cracking behavior and tension stiffening effect in a reinforced concrete(RC) tension member is proposed. Unlike the classical approaches using the bond stress-slip relationship or the assumed bond stress distribution, the tension stiffening effect at post-cracking stage is quantified on the basis of polynomial strain distribution functions of steel and concrete, and its contribution is implemented into the reinforcing steel. The introduced model can be effectively used in constructing the stress-strain curve of concrete at post-cracking stage, and the loads carried by concrete and by reinforcing steel along the member axis can be directly evaluated on the basis of the introduced model. In advance, the prediction of cracking loads and elongations of reinforced steel using the introduced model shows good agreements with results from previous analytical studies and experimental data.

  • PDF

Post-Antibiotic Effect of DW-116, a New Quinoloen (새로운 퀴놀론 항균제 DW-116의 Post-Antibiotic Effect)

  • Choi, Keum-Hwa;Oh, Tae-Kwon;Baek, Moon-Chang;Kim, Byong-Kak;Choi, Eung-Chil
    • YAKHAK HOEJI
    • /
    • v.42 no.2
    • /
    • pp.229-231
    • /
    • 1998
  • The post-antibiotic effects (PAE) of DW-116 were evaluated against Bacillus subtilis ATCC 6633, Bacillus cereus ATCC 27348, Staphylococcus aureus ATCC 25923 , Escherichia coli ATCC 25922 and Pseudomonas aeruginosa MB4-16, repectively. Against gram-positive bacteria, PAEs of DW-116 were longer duration (20-35 min) than those of rufloxacin(1O-20 min), and shorter than those of ciprofloxacin (50-90 min). Especially, against E. coli, DW-116 and ciprofloxacin obtained approximately 3 hrs of PAES.

  • PDF