• Title/Summary/Keyword: Post Chamber

Search Result 136, Processing Time 0.029 seconds

Low frequency Instability in Hybrid Rocket Post-chamber Configuration (연소실 형상 변화에 의한 하이브리드 로켓의 저주파수 연소불안정)

  • Park, Kyungsu;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.29-36
    • /
    • 2014
  • Hybrid rocket displays many different low frequency pressure oscillations during combustion. Thermal lag between solid and gas phase is the primary mechanism to trigger low frequency pressure oscillations of around 10Hz, and Helmholtz or $L^*$ mode also produces other types of low frequency oscillations above 10 Hz which is associated with the change in combustion volume. Since the flow characteristics in hybrid rocket is very similar to those in solid rocket combustion, it is not surprising to observe similar pressure oscillation behaviors. Experimental test shows that combustion pressure suddenly turns into to a big amplitude oscillation around 10Hz then followed by returning to an original pressure level after a short period combustion. Further investigations show that this instability is independent of the change in O/F ratio at all. One of the possible candidates is the vortex shedding dynamics over the backward step in the post combustion chamber. It is required to investigate the low frequency oscillation mechanism in the future study.

Numerical Study of the Post Combustion Chamber of Grate Type Incinerator in Daejon 4th Industrial Complex (대전 4공단 소각로 후연소로 모델 연구)

  • Kim Hey-Suk;Shin Mi-Soo;Jang Dong-Soon;Park Byung-Soo;Um Tae-In
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.133-138
    • /
    • 2002
  • A 3-D axisymmetric computer program is developed to predict the NO behavior in SNCR system for the stoker incinerator with the waste treatment capacity, 200ton/day. To this end a turbulent reacting flow field calculation is made using proper assumption and empiricism. The stoker bed is assumed to be a homogeneous waste-volatilized gaseous state. The initial composition or reactants are assumed based on the data of the ultimate analysis. Turbulent is resolved by k-e model and turbulent reaction is handled by eddy-breakup model harmonized with empirical chemistry data for gaseous combustion, NO and urea reaction. The liquid droplet is traced by Lagrangian method incorporated by aerodynamic drag, Coriolis and crntrifugal forces. Radiation is treated by sensible heat loss model. Calculation results are in good agreement with experimental data at the outlet of post combustion chamber in Daejon 4th industrial complex. The flue gas shows the temperature range of $900\sim1000^{\circ}C$, velocity of 5m/s and NO concentration of 140ppm at the exit while the measured temperature, flue gas velocity and NO concentration are $967^{\circ}C$, $3\sim4m/s$ and $100\sim200ppm$respectively. Using the developed computer program a parametric study has been made with the variation of heat content of waste, castable length and SNCR variables for the determination of proper injector location. In general, the calculated results are consistent and physically acceptable.

  • PDF

High Frequency Oscillations and Low Frequency Instability in Hybrid Rocket Combustion (하이브리드 로켓 연소실험에서의 고주파수 진동과 저주파수 연소불안정)

  • Chae, Heesang;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.12
    • /
    • pp.1021-1027
    • /
    • 2018
  • Experimental studies have been conducted to verify that the positive coupling between pressure oscillation (p') and combustion oscillation (q') of high frequency range is a prerequisite for the initiation of low frequency instability in hybrid rocket combustion. The post-chamber length and combustion equivalence ratio were selected as critical parameters to control the phase difference between p' and q', and p' amplitude in relation to the suppression of LFI. In the results, even if the post-chamber length increases, the phase difference between p' and q' maintains below pi/2, which is a necessary condition for the LFI development, but the amplification of RI (Rayleigh index) was substantially decreased leading to a stable combustion. In addition, results confirmed that combustion stability is achieved by changing the momentary equivalence ratio and/or by suppressing the positive coupling status of p' and q'. Thus, the periodic amplification of RI was identified as the middle path of the mechanism of occurrence of LFI.

BACTERIOLOGIC IN VITRO CORONAL LEAKAGE STUDY OF BEFORE AND AFTER POST SPACE PREPARATION (Streptococcus mutans를 이용한 근관 치료 후 포스트 와동 형성 전후의 치관부 누출에 관한 연구)

  • Lee, Hyo-An;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.16-21
    • /
    • 2005
  • The purpose of present study was to compare the speed of coronal leakage before and after post space preparation using Streptococcus mutans. Forty straight extracted human teeth were selected. The crowns were removed to a uniform remaining root length 14 mm. Canals were enlarged by 06 taper $Profiles^{(R)}$ to a size $\#40$ as a master apical file. And these were filled with gutta percha point and $Tubuliseal^{(R)}$ sealer, using continuous wave technique. Groupings are as follows. Group 1 - These teeth were obturated without sealer. Group 2 - These teeth were obturated and covered the surface of the root completely with sticky wax. Group 3 - These teeth were obturated. Group 4 - These teeth were obturated and prepared for post space remaining 5 mm of gutta percha. The teeth were suspended in plastic tubes. The upper chamber received the bacterial suspension everyday to simulate clinical situation. The lower chamber consisted of BHI added Andrade's indicator. All roots in the positive control group (Group 1) turned yellow within 24 h and those of negative control group (Group 2) remained red throughout the experimental period (70 days) The samples of group 3 were contaminated within an average of 27.2 days. The samples of group 4 were contaminated within an average of 15.7 days, ranging from 9 to 22 days. There was significant difference between group 3 and group 4 statistically (p < 0.05).

Effect of Platelet-rich Plasma (PRP) on Regeneration of Rat Sciatic Nerve in a Silicone Chamber

  • Minn, Kyung-Won;Jeong, Eui-Cheol;Chang, Hak;Kwon, Sung-Tack;Kim, Suk-Wha;Baek, Rong-Min
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.105-109
    • /
    • 2010
  • Purpose: The purpose of this study is to determine the effect of platelet-rich plasma (PRP) on rat sciatic nerve regeneration in a 10 mm silicone chamber. Methods: A total of 6 inbred Lewis rats were used in this study. Bilateral sciatic neurectomy was performed on each rat. On one side, silicone chambers containing PRP solutions were implanted; on the contralateral side, the chambers without PRP were implanted as a control. In 12 weeks post-implantation, chambers were retrieved and both gastrocnemius muscles were excised. Nerves biopsy samples were examined under a light microscope after Masson trichrome staining. Results: Cross sections of the midpoints of PRP treated nerves were significantly larger and appeared more mature than those of controls. Conclusion: Based on morphological evidence, PRP has a positive effect on neural regeneration, and it may therefore be useful for treating peripheral nerve injuries.

Laser Microfabrication for Silicon Restrictor

  • Kim, Kwang-Ryul;Jeong, Young-Keun
    • Journal of Powder Materials
    • /
    • v.15 no.1
    • /
    • pp.46-52
    • /
    • 2008
  • The restrictor, which is a fluid channel from a reservoir to a chamber inside a thermal micro actuator, has been fabricated using ArF and KrF excimer lasers, Diode-Pumped Solid State Lasers (DPSSL) and femtosecond lasers for a feasibility study. A numerical model of fluid dynamics for the actuator chamber and restrictor is presented. The model includes bubble formation and growth, droplet ejection through nozzle, and dynamics of fluid refill through the restrictor from a reservoir. Since an optimized and well-fabricated restrictor is important for a high frequency actuator, some special beam delivery setups and post processing techniques have been researched and developed. The effects of variations of the restrictor length, diameter, and tapered shapes are simulated and the results are analyzed to determine the optimal design. The numerical results of droplet velocity and volume are compared with the experimental results of a cylindrical-shaped actuator. It is found that the micro actuators having tapered restrictors show better high frequency characteristics than those having a cylindrical shape without any notable decrease of droplet volume. The laser-fabricated restrictors demonstrate initial feasibility for the laser direct ablation technique although more development is required.

The Analysis of Axisymmetric Field Problem by C-1 FEM (C-1 유한요소법에 의한 축대칭장 문제의 해석)

  • Jang, I.K.;Kwak, D.S.;Shin, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.21-23
    • /
    • 1999
  • In this paper, the analysis of the electric field in the chamber of high voltage $SF_6$ GCB(Gas Circuit Breaker) is presented by using C-1 FEM. For this purpose, pre-processing program and post-processing program were developed for axisymmetirc 3 dimensional analysis and the electric field in cylindric chamber was analyzed. Important problem is that electric analysis must be considered coronal due to break-down of $SF_6$ when it is cutted off. To solve this problem, a procedure is needed to verify that the solution of Poisson's equation for scalar potential satisfy charge continuos condition because of using first order element os not satisfy the electric continuous condition, C-1 FEM is introduce to obtain electirc potential and electric field at the same time. Analysis of the distribution of electric field on model was done. It is confirmed that the developed program in this paper applicable to design and to analyze of characteristics in total program as electric characteristics analysis routine.

  • PDF

The LaserFIB: new application opportunities combining a high-performance FIB-SEM with femtosecond laser processing in an integrated second chamber

  • Ben Tordoff;Cheryl Hartfield;Andrew J. Holwell;Stephan Hiller;Marcus Kaestner;Stephen Kelly;Jaehan Lee;Sascha Muller;Fabian Perez-Willard;Tobias Volkenandt;Robin White;Thomas Rodgers
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.24.1-24.11
    • /
    • 2020
  • The development of the femtosecond laser (fs laser) with its ability to provide extremely rapid athermal ablation of materials has initiated a renaissance in materials science. Sample milling rates for the fs laser are orders of magnitude greater than that of traditional focused ion beam (FIB) sources currently used. In combination with minimal surface post-processing requirements, this technology is proving to be a game changer for materials research. The development of a femtosecond laser attached to a focused ion beam scanning electron microscope (LaserFIB) enables numerous new capabilities, including access to deeply buried structures as well as the production of extremely large trenches, cross sections, pillars and TEM H-bars, all while preserving microstructure and avoiding or reducing FIB polishing. Several high impact applications are now possible due to this technology in the fields of crystallography, electronics, mechanical engineering, battery research and materials sample preparation. This review article summarizes the current opportunities for this new technology focusing on the materials science megatrends of engineering materials, energy materials and electronics.

A Clinical Study of Ocular Dimention and Visual Acuity Before and After Cataract Surgery Over Ninety Years Old (90세 이상 초고령 환자들의 백내장 수술전.후 안수치와 시력에 관한 임상연구)

  • Lee, Jung-Mi;Kim, In-Suk;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 2010
  • Propose: Due to the rapid growth of medical technologies and the increasing population of older people, we investigated clinical status of ocular dimensions and visual acuity for pre and post cataract surgeries of people over age 90. Methods: From March 2007 to February 2009, we investigated eighty-two eyes of forty-eight patients who had undergone cataract surgeries at an ophthalmic clinic (Ansung, Kyungi-do), investigated maximum corrected vision, axial length, anterior chamber depth and accompanied ocular diseases before and after the surgeries based on the collected data. Results: As patients aged, axial length unchanged but anterior chamber depth decreased over all due to the increase of intraocular lens thickness, and men tended to have a higher degree than women. Seventy-one (86.6%) of eighty-two eyes showed improved corrected vision than before surgeries and forty-three (52.4%) eyes could see more than visual acuity of 0.5. Conclusions: Patients with the systemic disease and accompanied ocular disease showed low vision less than 0.5 after cataract surgery compared to same healthy age peoples. But the others improved correction visual acuity more than 0.5, so the cataract surgery was surely necessary for people over 90 years old and also the presence of ocular disease could have a great influence on correction visual acuity.

FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION ACCORDING TO THE METHOD OF RESTORATION AFTER ROOT CANAL THERAPY (상악 중절치 근관치료후 수복 방법에 따른 응력 분포의 유한 요소 분석)

  • Lee, Jae-Young;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.549-567
    • /
    • 1994
  • Restoration of severly damaged teeth after endodontic treatment had been an interest to many dentists, and it is a fact that there have been lots of studies about it. In these days, although we have used Para-Post, pins, threaded steel post, cast gold post and core, and so on, as a method of restoration frequently, it has been in controversy with the influence of them on the teeth and surrounding periodontal tissue. In this study, we assume that the crown of the upper incisor have severly damaged, so, after the root canal therapy, 4 types of restoration had been carried out; 1) coronal-radicular amalgam restoration, 2) after setting up the Para-Post, restore with composite resin core only, 3) after setting up the Para-Post; restore with amalgam core, then cover with the PPM crown 4) after setting up the Para-Post, restore with composite core, then cover with the PPM crown. After restoration, in order to observe the concentration of stress at internal portion of the teeth and the sourrounding periodontal tissue, developing a 2-dimensional finite element model of labiopalatal section, then loading forces from 3 direction - direction of 45 degrees from lingual side near the incisal edge, horizontal direction from labial height of contour, vertical direction at the incisal edge-were applied. The analyzed results were as follows: 1. Stress of the normal central incisor was concentrated on the dentin aroundpulp chamber, labiocervical portion of a tooth and root apex, but with the alveolar bone, in the case of load from the direction of 45 degrees from lingual side near the incisal edge showed remarkable concentration of stress: 2. Coronal-radicular amalgam technique -showed less concentration of stress on the root and surrounding periodontal tissue than the restoration with the Para-Post. 3. The von Mises equivalent stress on the Para-Post showed maximum value at root-core junction rather than both ends and model with PPM restoration with amalgam core showed the least concentration of stress. Only the force from horizontal direction showed large shear stress on internal portion of the root, root apex and alveolar bone. 4. PPM crown with composite core rarely showed the concentration of stress on root and periodontal tissue. 5. As for alveolar bone, remarkable shear stress was concentrated on labial and palatal side by horizontal load.

  • PDF