• 제목/요약/키워드: Possibility of a fire

검색결과 324건 처리시간 0.029초

화재모델링을 이용한 입출력 변수의 민감도, 상관계수 분석과 주성분 분석 (Analysis of Sensitivity, Correlation Coefficient and PCA of Input and Output Parameters using Fire Modeling)

  • 남기태;김정진;윤석표;김준경
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.46-54
    • /
    • 2019
  • Even though the fire performance-based design concept has been introduced for various structures and buildings, which have their own specific fire performance level, the uncertainties of input parameters always exist and, then, could reduce significantly the reliability of the fire modeling. Sensitivity analysis was performed with three limited input parameters, HRRPUA, type of combustible materials, and mesh size, which are significantly important for fire modeling. The output variables are limited to the maximum HRR, the time reaching the reference temperature($60^{\circ}C$), and that to reach limited visible distance(5 m). In addition, correlation coefficient analysis was attempted to analyze qualitatively and quantitatively the degree of relation between input and output variables above. Finally, the relationship among the three variables is also analyzed by the principal component analysis (PCA) to systematically analyze the input data bias. Sensitivity analysis showed that the type of combustible materials is more sensitive to maximum HRR than the ignition source and mesh size. However, the heat release parameter of the ignition source(HRR) is shown to be much more sensitive than the combustible material types and mesh size to both time to reach the reference temperature and that to reach the critical visible distance. Since the derived results can not exclude the possibility that there is a dependency on the fire model applied in this study, it is necessary to generalize and standardize the results of this study for the fire models such as various buildings and structures.

The research on changes in turnover intention due to the degree of occupational stress and the mediating parameters in fire-officerse Mice

  • kang, Kwang Soon;Ji, Dong Ha
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권7호
    • /
    • pp.109-115
    • /
    • 2017
  • This study was performed to investigate the changes in turnover intention according to the level of occupational stress and to find the mediating factor that reducing the turnover intention among fire officer. To compare change of turnover intention according to the degree of occupational stress, statistical analyses were done by using the logistic regression model. In logistic regression analysis, the possibility of high turnover intention in a group with high occupational stress was hjgher by 4.11 times than a group with low occupational stress. The results of analyzing the degree of change in turnover intention after applying the mediating parameters(physical condition, emotional labor, burn out), turnover intention decreased by about 50.6%(from 4.11 times to 2.03 times) at the high level of occupational stress. As a result, it was found that the occupational stress experienced by the fire-officers had a positive effect on the turnover intention. In order to reduce the turnover intention due to the occupational stress of the fire-officers, it is necessary to manage factors such as work environmental factors(emotional labor, burn out) and individual factor(physical condition).

콘칼로리미터를 이용한 내장판용 복합재료의 화재특성 (Fire Characteristics of Composites for Interior Panels Using Cone calorimeter)

  • 이철규;정우성;이덕희
    • 한국철도학회논문집
    • /
    • 제7권1호
    • /
    • pp.55-59
    • /
    • 2004
  • Composite materials were used widely due to merit of light weight, low maintenance cost and easy installation. But it is the cause of enormous casualties to men and properties because of weak about the fire. Particularly, it is more serious in case of subway train installed composite materials. For this reason, experimental comparison has been done fur measuring heat release rate(H.R.R) and smoke production rate(S.P.R) of interior panels of electric motor car using cone calorimeter. A high radiative heat flux of 50kW/㎡ was used to bum out all materials and to simulate the condition of fully developed fire case in the tests. It was observed that Heat Release Rate and Smoke Production Rate curves were dependent on the kinds of the interior materials. From the heat release rate curves, the sustained ignition time, peak heat release rate and total heat release rate were deduced, These data are useful in classifying the materials by calculating two parameters describing the possibility to flashover.

콘칼로리미터를 이용한 건축용 막재의 내화 특성 연구 (A Fire Resistance Property Study of Architectural Fabric using Cone Calorimeter)

  • 김지현;신현욱;송훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.158-159
    • /
    • 2015
  • Architectural fabrics are now used in membrane structure with the merits of free shape, lightness and opened up new possibility for the design of new building structures. Recently PVC, PVF, PVDF, PTFE coated fabric for using the membrane structures. However, clear standards for the design and construction is not exist because of the lack of Architectural fabric research. In this paper, Flammable properties of PVDF, PTFE coated fabrics are obtained through the Flammability test using the Cone Calorimeter. Based on these results, identify the fire resistance property of the Architectural fabric.

  • PDF

송전용 폴리머 애자의 산불 모의시험에 따른 표면열화 특성 (Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.110-110
    • /
    • 2010
  • Suspension insulator have made use of porcelain insulator mainly, but polymer insulator is using recently. Polymer suspension insulator have advantage that it is light than porcelain insulator. The ageing performance is excellent and it is possible for mass production. There is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground Therefore surface aging of polymer insulator most of the overhead transmission lines in Korea are operated on the mountain need analysis of transmission line into forest fire. surface aging property is analyzed by SEM, EDX, XPS, FTIR, DSC in this paper.

  • PDF

통전전류 특성을 이용한 모터 기동용 전해 커패시터 폭발 방지 방법 (The Explosion Prevention Method for Electrolytic Motor Start Capacitors using Current Characteristic)

  • 김재현;박진영;박광묵;방선배;김용운
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1836-1843
    • /
    • 2017
  • In this paper, we investigated fire cases those are believed to be caused by explosion of a electrolytic motor start capacitor. Using two types of commercially available electrolytic motor start capacitors, capacitor current and the possibility of capacitor explosion were tested. And the ignition possibility of the internal material leaked from a capacitor was also tested. In addition, experiments were conducted to see if the fire could spread when a capacitor was exposed to an external flame. From our test we observed that the current of the electrolytic motor start capacitor rose continuously to a certain level by product, if the capacitor was continuously energized with working voltage, and then the capacitor was exploded. The gas and liquid leaked from the capacitor by the explosion could ignite by an electric arc and an external flame. The capacitor current at explosion was different product by product, but each product had a certain current level at explosion. And the increase rate of the capacitor current until explosion was 24% and 31% for the products used in the experiment. We proposed the capacitor explosion prevention method that cuts off power when the capacitor current rises to a certain threshold level. The proposed method can be used if the current of the applied electrolytic motor start capacitor rises continuously and then the capacitor is exploded at a certain current level when the capacitor is energized continuously.

고주파 특성과 스마트폰을 활용한 화재 대피 안내시스템 개발 (Development of Fire Evacuation Guidance System using Characteristics of High Frequency and a Smart Phone)

  • 전유진;전연수;염춘호
    • 한국정보통신학회논문지
    • /
    • 제24권10호
    • /
    • pp.1376-1383
    • /
    • 2020
  • 화재 대피시스템에 관한 연구가 증가하고 있지만, 실내공간에서 대피자의 위치 인식에 관한 연구는 부족한 실정이다. 최신 연구에 따르면 실내에서 대피자 위치 파악에 고주파 활용이 효과적일 수 있음을 제시한 바가 있다. 이에 따라 본 논문에서는 고주파 특성과 스마트폰을 활용한 대피자 위치 인식 기술 및 화재 대피 안내시스템을 개발하고자 한다. 전체 시스템은 앱 서버, 위치 인식부, 대피경로 탐색 및 출력부, Wi-Fi통신 기반의 스피커 출력부를 포함해 개발했으며, 화재 상황 데이터를 기반으로 실험을 수행하여 시스템의 실효성에 대한 가능성을 입증하였다. 본 연구는 화재 시 고주파를 활용한 대피자 위치 감별을 사용하는 화재 대피 안내시스템의 기초연구로 활용될 수 있을 것이라 기대된다.

옥내소화전 방수구에 부착되는 감압오리피스의 감압성능에 관한 연구 (Performance of Decompression Orifices Attached to Indoor Hydrant Discharge Outlets)

  • 박봉래;이맹로;장경남;백은선
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.6-12
    • /
    • 2015
  • 소화설비는 초기소화를 목적으로 설치하여 소방대의 본격소화활동이전에 사용하는 소방설비로서 소화성능은 물론 사용자의 안전을 보장하여야 한다. 옥내소화전설비의 경우 건축물에 많이 설치된 소화설비로서 화재 시 사용자가 밸브조작 및 호스와 노즐을 수동으로 사용해야하는 설비이다. 따라서 방수압력이 0.70 MPa보다 높은 경우 조작과 호스파손 등의 문제가 발생할 수 있다. 이를 방지하기위해 사용되는 감압방식 중 옥내소화전방수구인 앵글밸브에 오리피스형태인 감압밸브를 부착하는 방식을 많이 사용하고 있다. 하지만 감압밸브는 구조적인 문제로 인하여 사용기간의 경과에 따라 감압성능이 저하되는 것을 확인하였다. 이에 따라 3단계의 초기압력을 기준으로 감압오리피스의 직경별 감압성능을 측정하여 적용 가능한 압력범위를 선정하고 이를 자료로 시간경과에도 감압성능의 저하를 최소화 하는 안정적인 감압밸브 모델을 제시하였다.

소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구 (An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents)

  • 한용택;김동호;권성필
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.1-7
    • /
    • 2014
  • 자동차의 엔진룸의 내부를 살펴보면 여러 가지의 장치 및 장비가 복잡하게 설치되어 있고 각종 오일 등의 인화물질을 포함하고 있어 재발화 가능성이 매우 높다. 또한, 폭발가능성도 높기 때문에 운전자나 탑승자가 보닛을 열고 엔진룸에 직접 분말 소화기를 분사하는 방식으로는 한계가 있다. 따라서 엔진룸 내부에서 화재를 감지하여 소화약제를 분사한 뒤, 화재를 진화하는 소화시스템과 엔진룸 내부의 고열에 견딜 수 있고, HFC-227ea를 포함하는 충분한 점성을 가진 폼 형태의 소화약제를 개발 및 시험하였다. 그리고 포소화약제가 가지고 있는 소화원리인 질식 및 냉각효과와 HFC-227ea가 가진 부촉매효과를 동시에 이끌어 내고, 소화 후에도 분말 소화기처럼 잔존물에 의한 2차 피해가 없는 맞춤형 소화약제를 개발하였으며, 차량을 이용한 충돌실험을 통하여 방출이 완료된 후에도 이물질 없이 소화약제를 제거할 수 있는 장점이 존재하는 실험결과를 획득하였다.

뒷불 특성에 관한 실험방법 연구 (The Study on Experimental Method of Smoldering Ground Fire in Forest Fire)

  • 김동현;김장환;김응식
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.1-6
    • /
    • 2010
  • 산불 형태 중에서 뒷불은 지표층 내부의 발화점 이상 온도가 분해층에서 부식층으로 전이되어 뒷불이 발생 할 수 있는 형태로 잠재적 위험성을 가지고 있다. 본 논문은 뒷불의 현장과 유사한 지표층 구조로 설정하여 실험을 통해 뒷불의 잠재적 위험성과 연소특성 규명을 목적으로 한다. 시료는 침엽수종 소나무 낙엽층과 활엽수종 굴참나무 낙엽층으로, 실제 산림내의 지표층 구조인 낙엽층, 분해층, 부식층로 구분하여 재현하였다. 8개의 열전대(K-type)를 층별 경계면과 그 사이에 배치하여 전이온도, 지속시간, 전파속도를 측정하였다. 결과적으로 F-H층으로 전이되는 경우와 전이가 일어나지 않은 경우는 L층과 F층 경계면의 발화조건이며, 유기물층의 뒷불 전이 임계습도는 35~44% 사이에 존재하며, 온도는 $350^{\circ}C$ 이상시 뒷불 전이가 일어날 확률이 아주 높다는 결론을 도출하였다. 본 연구에서는 다층구조의 뒷불 모델을 제시하였으며 이를 사용하여 훈소의 층간 전이현상, 함수율에 따른 발화여부, 전파속도 및 시간에 따른 경계면의 온도변화 등을 알 수 있었다. 또한 뒷불의 연소특성을 규명할 수 있는 실험방법을 확립하였다.