• 제목/요약/키워드: Positioning reproducibility

검색결과 25건 처리시간 0.019초

Comparison of the reproducibility of panoramic radiographs between dentulous and edentulous patients

  • Park, Jong-Woong;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.95-102
    • /
    • 2014
  • Purpose: This study was performed to evaluate the reproducibility of panoramic radiographs of dentulous and edentulous patients. Materials and Methods: The reproducibility of panoramic radiographs was evaluated using the panoramic radiographs acquired from 30 anterior dentulous patients by using a common biting positioning device (dentulous group) and 30 anterior edentulous patients by using chin-support devices to take a panoramic radiograph (edentulous group), respectively; these patients had undergone 3 or more panoramic radiographs. The widths and angles between the designated landmarks were measured on the panoramic radiographs, and the reproducibility was evaluated using the intraclass correlation coefficient (ICC) and the coefficient of variation. Results: In the dentulous and edentulous groups, the ICCs of the mandibular ramus and mandibular angle areas were higher than the condylar head and zygomatic areas. The mandibular ramus and angle areas showed statistically lower mean coefficients of variation than the condylar head and zygomatic areas in the dentulous group. The mandibular angle area showed a significantly lower mean coefficient of variation than the zygomatic area in the edentulous group. By comparing the two groups, each ICC of the edentulous group was lower than that of the dentulous group, and the mean coefficients of variation of the mandibular ramus area, zygomatic area, left condylar inclination, and ramus ratio between the right and the left in the edentulous group were significantly higher than those in the dentulous group. Conclusion: Biting positioning for dentulous patients provided better positioning reproducibility than chin-support positioning when performing panoramic radiography for edentulous patients.

보조기구를 이용한 DR System 활용 방법에 대한 연구 (A Study on how to Utilize the DR System using Assistive Devices)

  • 서선열;김정호;이진옥
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.115-122
    • /
    • 2023
  • 엉덩관절 고정기구는 골밀도 검사 및 미세골절, 관절염의 진단 시 내회전을 위한 중요 고정기구입니다. 이러한 고정기구는 벨크로를 사용하여 재현성 유지에 한계가 있습니다. 이에 본 연구에서는 개선된 엉덩관절 고정기구를 개발하여 유용성을 평가하였습니다. 방사선과 재학생 30 명을 대상으로 기존과 개선된 고정기구를 적용하여 자세잡이 소요시간과 의료영상을 통한 재현성을 평가하였습니다. 또한, 시간경과에 따른 변화도 평가하였습니다. 그 결과 기존 고정기구에 비해 개선된 고정기구는 자세잡이 시간은 약 32%의 감소를 보였으며, 재현성은 약 6.2 배 향상되었습니다. 시간경과에 따른 변화량은 자세잡이 시간은 기존 고정기구는 증가된 반면 개선된 고정기구는 감소되었으며, 재현성은 개선된 고정기구보다 기존 고정기구가 더 저하되었습니다. 이를 통해 개선된 고정기구의 사용을 통해 영상의 질 향상과 방사선사의 업무부담 감소가 나타났다고 할 수 있습니다.

A new bite block for panoramic radiographs of anterior edentulous patients: A technical report

  • Park, Jong-Woong;Symkhampha, Khanthaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Panoramic radiographs taken using conventional chin-support devices have often presented problems with positioning accuracy and reproducibility. The aim of this report was to propose a new bite block for panoramic radiographs of anterior edentulous patients that better addresses these two issues. Materials and Methods: A new panoramic radiography bite block similar to the bite block for dentulous patients was developed to enable proper positioning stability for edentulous patients. The new bite block was designed and implemented in light of previous studies. The height of the new bite block was 18 mm and to compensate for the horizontal edentulous space, its horizontal width was 7 mm. The panoramic radiographs using the new bite block were compared with those using the conventional chin-support device. Results: Panoramic radiographs taken with the new bite block showed better stability and bilateral symmetry than those taken with the conventional chin-support device. Patients also showed less movement and more stable positioning during panoramic radiography with the new bite block. Conclusion: Conventional errors in panoramic radiographs of edentulous patients could be caused by unreliability of the chin-support device. The newly proposed bite block for panoramic radiographs of edentulous patients showed better reliability. Further study is required to evaluate the image quality and reproducibility of images with the new bite block.

초정밀 선삭가공을 위한 글로벌스테이지의 재현성 실험 (Global Stage of Reproducibility Experiment for Single Point Diamond Turning)

  • 박대광;곽남수;권대주;김재열
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.982-988
    • /
    • 2013
  • With conventional positioning apparatus, it is very difficult to simultaneously achieve the desired driving range and precision at the sub-micrometer level. Generally, lead screw and friction drive, etc., have been used as servo control systems. These have large driving ranges, and high-speed positioning is feasible. In this study, we present a global servo system controlled by a laser interferometer acting as a displacement measurement sensor for achieving positioning accuracy at the sub-micrometer level.

Patient-specific Guides Using 3-dimensional Reconstruction Provide Accuracy and Reproducibility in Reverse Total Shoulder Arthroplasty

  • Yoon, Jong Pil;Kim, Dong Hyun;Jung, Jae Wook;Lee, Chang-Hwa;Min, Seunggi;Lee, Hyun Joo;Kim, Hee-June
    • Clinics in Shoulder and Elbow
    • /
    • 제22권1호
    • /
    • pp.16-23
    • /
    • 2019
  • Background: We aimed to evaluate whether the use of our novel patient-specific guide (PSG) with 3-dimensional reconstruction in reverse total shoulder arthroplasty (RTSA) would allow accurate and reliable implantation of the glenoid and humeral components. Methods: 20 fresh-frozen cadaveric shoulders were used. The PSG group (n=10) and conventional group (n=10) was evaluated the accuracy and reproducibility of implant positioning between before and after surgery on the computed tomography image. Results: The superoinferior and anteroposterior offset in the glenoid component were $0.42{\pm}0.07$, $0.50{\pm}0.08$ in the conventional group and $0.45{\pm}0.03$, $0.46{\pm}0.02$ in the PSG group. The inclination and version angles were $-1.93^{\circ}{\pm}4.31^{\circ}$, $2.27^{\circ}{\pm}5.91^{\circ}$ and $0.46^{\circ}{\pm}0.02^{\circ}$, $3.38^{\circ}{\pm}2.79^{\circ}$. The standard deviation showed a smaller difference in the PSG group. The anteroposterior and lateromedial humeral canal center offset in the humeral component were $0.45{\pm}0.12$, $0.48{\pm}0.15$ in the conventional group and $0.46{\pm}0.59$ (p=0.794), $0.46{\pm}0.06$ (p=0.702) in the PSG group. The PSG showed significantly better humeral stem alignment. Conclusions: The use of PSGs with 3-dimensional reconstruction reduces variabilities in glenoid and humerus component positions and prevents extreme positioning errors in RTSA.

Reproducibility of cone-beam computed tomographic measurements of bone plates and the interdental septum in the anterior mandible

  • Valerio, Claudia Scigliano;Alves, Claudia Assuncao e;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • 제49권1호
    • /
    • pp.9-17
    • /
    • 2019
  • Purpose: This study aimed to introduce a novel method to evaluate the alveolar bone and interdental septum in the anterior mandible using cone-beam computed tomography (CBCT). Materials and Methods: Fifty-six CBCT scans from adult patients were selected. The CBCT scans were obtained before and after orthodontic treatment. The following measurements were taken: width of the alveolar bone and the interdental septum, height of the interdental septum, height of the bone plates, distance between the cementoenamel junction and marginal bone crests, and vertical positioning of the mandibular incisor, using the lingual plane as a reference. To test the reproducibility and the stability of the lingual plane, a triangle was traced in the anterior mandible. The intra-class correlation coefficient(ICC) was used to determine intra- and inter-examiner agreement. The paired Student t-test was used to evaluate the area of the triangle and the reproducibility of all measurements. Results: The ICC was excellent for the alveolar bone and dental measurements (0.9989 and 0.9977, respectively), as well as for the interdental septum (0.9987 and 0.9961, respectively). The area of the triangles showed stability in the lingual plane (P>0.05). For the alveolar bone, mandibular incisor, and interdental septum measurements, no statistically significant differences were found between the 2 examiners(P>0.05), confirming the technical reliability of the measurements. Conclusion: The method used in this study provides a valid and reproducible assessment of alveolar bone dimensions in the anterior mandible measured on CBCT images.

초음파 영상에 의한 골밀도 측정에서 관심영역의 자동 검출방법 (Automatic Detection Method of the Region of Interest in the Measurement of Bone Mineral Density by Ultrasound Imaging)

  • 신정식;안중환;한은옥;김형준;한승무
    • 한국정밀공학회지
    • /
    • 제21권11호
    • /
    • pp.200-208
    • /
    • 2004
  • In ultrasonic bone densitometry, the positioning of measurement site is decisive in precision and reproducibility. In this study, automatic Region of Interest (ROI) detection algorithm is suggested and adopted the method using the local minimum value by ultrasonic image. The preprocess before the local minimum method extracts out the bone area and calculates the geometrical information of bone. The developed ROI detection algorithm was applied to the clinical test for the subject of 305 female patients in the range of 22-88 years old. As the results, the accuracy of the algorithm was shown to be 98.3%. It was also found that bone density parameter was significantly correlated with age(r=0.85, p<0.0001).

A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scans

  • Na, Eui-Ri;Aljawad, Hussein;Lee, Kyung-Min;Hwang, Hyeon-Shik
    • 대한치과교정학회지
    • /
    • 제49권1호
    • /
    • pp.41-48
    • /
    • 2019
  • Objective: This in-vivo study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from cone-beam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings. Methods: AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters. Results: Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experienceor projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks. Conclusions: The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.

두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가 (Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy)

  • 이경진;손상준;임경달;김찬용;이제희
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.21-30
    • /
    • 2022
  • 목 적: 본원에서 방사선치료를 받는 두경부암 환자들에게 적용하기 위하여 도입한 구강용 고정장치 BinkieRTTM의 구강 내 재현성을 평가하고 기존 고정장치와의 재질과 선량 비교를 통해 그 유용성을 평가하고자 한다. 대상 및 방법: BinkieRTTM를 사용하여 치료한 두경부암 환자 24명을 대상으로 혀 재현성 평가를 위해 치료계획용 CT와 치료 중 3일 간격으로 촬영된 CBCT영상에 혀를 그린 후 DSC와 중심축 이동값을 분석하였다. 또한 BinkieRTTM를 사용하는 경우와 다른 종류의 구강 고정장치(mouth piece, paraffin wax)를 사용했을 때 선량 분포측면에서 혀에 조사되는 선량을 비교하였다. 이를 위해 상악에 위치한 종양 치료를 받는 환자들과 편측 두 경부암 환자들을 각 10명씩 선정하고 전산화 치료 계획 시 혀에 조사되는 선량을 확인하였다. 마지막으로 재질 평가 측면에서는 임상에서 혀를 치료부위 반대 방향으로 보내 고정하는 목적으로 많이 사용하는 Paraffin Wax나 Putty와의 비교를 통하여 BinkieRTTM의 단순 물질 특성을 알아보기 위해 전산화 치료 장비로 Mass density 및 상대전자밀도 등을 확인하고, 팬텀과 이온챔버를 이용하여 Transmission Factor를 측정하였다. 결 과: BinkieRTTM를 사용 시 DCS (n=144) 의 평균은 0.8 ± 0.07, 95% 신뢰구간은 0.79~0.82 로 나타났고, 빈도분포 분석 결과는 왜도 -0.8, 첨도 0.61 로 나타났다. 치료 기간 중 혀 중심축 이동에 대한 편차를 분석하기 위해 LR, SI, AP 방향 이동에 대한 95% 신뢰구간과 편차의 이상값인 0에 대한 일표본 t검정을 실시하였다.(n=144) t검정 결과 LR, SI 방향의 평균은 각각 0.01 ± 0.14 cm(p>.05), 0.03 ± 0.25 cm(p>.05), AP 방향은 -0.08 ± 0.25 cm(p<.05) 로 나타났다. 혀를 치료부위의 반대 방향으로 고정한 경우인 편측 귀밑샘 종양 환자들의 경우 BinkieRTTM를 사용한 환자들의 혀 평균선량은 처방선량 대비 평균 16.92% ± 3.58%, Paraffin Wax 환자 23.99% ± 10.86% 로 BinkieRTTM 사용 시 혀 선량이 비교적 더 낮은 것으로 나타났다(p<.05). 반면, 혀를 아래로 누르는 목적으로 BinkieRTTM를 사용한 환자들 중 비강암 환자의 혀 평균선량은 평균 4.4% ± 5.6%, mouth piece를 사용한 환자들은 5.9% ± 6.8% 로 나타났으나, 통계적으로 유의하지 않았다(p>.05). Paraffin Wax와 BinkieRTTM, Putty의 상대전자밀도 측정 결과 각각 0.94, 0.99, 1.26, Transmission Factor는 각각 0.99, 0.98, 0.96로 나타났다. 결 론: BinkieRTTM의 치료기간에 걸쳐 나타난 혀 DSC분석 결과는 약 0.8, 고정력은 LR, SI 방향으로의 편차가 0에 가까울 정도로 매우 우수하였으며, AP방향의 고정력 또한 평균 0.08 cm 로 우수한 편이었다. 또한 혀를 옆으로 밀어 치료부위 반대 방향으로 고정하는 편측 두경부암 환자의 경우 Paraffin wax나 Putty를 사용하는 것보다 BinkieRTTM를 사용하는 것이 혀에 조사되는 불필요한 선량을 줄일 수 있는 것으로 나타났다. 그러므로 본 실험 결과와 BinkieRTTM의 특성을 적절히 고려하여 두경부암 치료에 적용한다면 혀의 재현성 유지 및 선량 감소에 도움이 되리라 사료된다.

New Material and Processing Issues for High Quality Parts by Micro-MIM

  • Rota, A.;Imgrund, Ph.;Haack, J.;Petzoldt, F.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.34-35
    • /
    • 2006
  • The development of Micro MIM as a new manufacturing process for metallic micro parts made of advanced functional materials has been the subject of considerable research over the last years. This paper addresses important quality aspects on processing of new materials by Micro-MIM. Three examples of new functional materials that can be processed are reviewed in this paper. The first example is two-component-Micro-MIM to obtain multi-functional devices. A micro positioning encoder consisting of a magnetic / non-magnetic material combination is presented. The second issue is series production of the replicate of the smallest human bone in the ear (stapes) from Titanium as an example of medical application. Quality assurance and reproducibility in terms of injection moulding parameters are addressed. In the third part, first results on the processing of the shape memory alloy NiTi by Micro-MIM are presented. Potential applications include biocompatible devices and transportation, for example automotive and aerospace. Processing routes and initial microstructures obtained are discussed.

  • PDF