DOI QR코드

DOI QR Code

A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scans

  • Na, Eui-Ri (Department of Periodontology, School of Dentistry, Chonnam National University) ;
  • Aljawad, Hussein (Department of Orthodontics, School of Dentistry, Chonnam National University) ;
  • Lee, Kyung-Min (Department of Orthodontics, School of Dentistry, Chonnam National University) ;
  • Hwang, Hyeon-Shik (Department of Orthodontics, School of Dentistry, Chonnam National University)
  • Received : 2018.04.11
  • Accepted : 2018.07.18
  • Published : 2019.01.25

Abstract

Objective: This in-vivo study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from cone-beam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings. Methods: AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters. Results: Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experienceor projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks. Conclusions: The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.

Keywords

References

  1. Broadbent BH. A new x-ray technique and its application of orthodontia. Angle Orthod 1931;1:45-66.
  2. Mulick JF. Clinical use of the frontal headfilm. Angle Orthod 1965;35:299-304.
  3. Ricketts RM, Bench RW, Hilgers JJ, Schulhof R. An overview of computerized cephalometrics. Am J Orthod 1972;61:1-28. https://doi.org/10.1016/0002-9416(72)90172-8
  4. Grummons DC, Kappeyne MA. A frontal asymmetry analysis. J Clin Orthod 1987;21:448-65.
  5. Whaites E. Essentials of dental radiography and radiology. In: Whaites E, ed. X-ray equipment, films and processing. 3rd ed. London: Churchill Livingstone; 2002. p. 35-40.
  6. Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA. A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 1998;8:1558-64. https://doi.org/10.1007/s003300050586
  7. Farman AG, Scarfe WC. Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2006;130:257-65. https://doi.org/10.1016/j.ajodo.2005.10.021
  8. Moshiri M, Scarfe WC, Hilgers ML, Scheetz JP, Silveira AM, Farman AG. Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2007;132:550-60. https://doi.org/10.1016/j.ajodo.2006.09.046
  9. Kumar V, Ludlow J, Soares Cevidanes LH, Mol A. In vivo comparison of conventional and cone beam CT synthesized cephalograms. Angle Orthod 2008;78:873-9. https://doi.org/10.2319/082907-399.1
  10. Cevidanes L, Oliveira AE, Motta A, Phillips C, Burke B, Tyndall D. Head orientation in CBCT-generated cephalograms. Angle Orthod 2009;79:971-7. https://doi.org/10.2319/090208-460.1
  11. van Vlijmen OJ, Berge SJ, Bronkhorst EM, Swennen GR, Katsaros C, Kuijpers-Jagtman AM. A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls. Int J Oral Maxillofac Surg 2009;38:773-8. https://doi.org/10.1016/j.ijom.2009.02.024
  12. Sun MK, Uhm GS, Cho JH, Hwang HS. Use of head posture aligner to improve accuracy of frontal cephalograms generated from cone-beam CT scans. Korean J Orthod 2009;39:289-99. https://doi.org/10.4041/kjod.2009.39.5.289
  13. Hwang HS, inventor. Chonnam University Industry-Academic Cooperation Foundation, assignee. Ear plug for forming reference axis in CT taking. Korean Patent 10-0884354. 2009 Feb 7.
  14. Kim EH, Hwang HS. The validity of head posture aligner in posteroanterior cephalometry. Korean J Orthod 2000;30:543-52.
  15. Leonardi RM, Giordano D, Maiorana F, Greco M. Accuracy of cephalometric landmarks on monitor-displayed radiographs with and without image emboss enhancement. Eur J Orthod 2010;32:242-7. https://doi.org/10.1093/ejo/cjp122
  16. Proffit WR. The search for truth: Diagnosis in surgical orthodontic treatment. St. Louis: Mosby Year Book; 1996. p. 127-8.
  17. Koh EH, Lee KH, Hwang HS. Effects of vertical head rotation on the posteroanterior cephalometric measurements. Korean J Orthod 2003;33:73-84.
  18. El-Mangoury NH, Shaheen SI, Mostafa YA. Landmark identification in computerized posteroanterior cephalometrics. Am J Orthod Dentofacial Orthop 1987;91:57-61. https://doi.org/10.1016/0889-5406(87)90209-5
  19. Athanasiou AE, Miethke RR, Van Der Meij AJ. Random errors in localization of landmarks in posteroanterior cephalograms. Br J Orthod 1999;26:273-84. https://doi.org/10.1093/ortho/26.4.273
  20. Eppley BL, Sadove AM. Computerized digital enhancement in craniofacial cephalometric radiography. J Oral Maxillofac Surg 1991;49:1038-43. https://doi.org/10.1016/0278-2391(91)90133-7
  21. Wiesemann RB, Scheetz JP, Silveira A, Farman TT, Farman AG. Cephalometric landmark clarity in photostimulable phosphor images using pseudo-color and emboss enhancements. Int J CARS 2006;1:105-12. https://doi.org/10.1007/s11548-006-0042-8
  22. Korner M, Weber CH, Wirth S, Pfeifer KF, Reiser MF, Treitl M. Advances in digital radiography: physical principles and system overview. Radiographics 2007;27:675-86. https://doi.org/10.1148/rg.273065075

Cited by

  1. Automatic Cephalometric Landmark Identification System Based on the Multi-Stage Convolutional Neural Networks with CBCT Combination Images vol.21, pp.2, 2019, https://doi.org/10.3390/s21020505
  2. Evaluation of a multi-stage convolutional neural network-based fully automated landmark identification system using cone-beam computed tomography-synthesized posteroanterior cephalometric images vol.51, pp.2, 2021, https://doi.org/10.4041/kjod.2021.51.2.77