• Title/Summary/Keyword: Position of fan

Search Result 136, Processing Time 0.025 seconds

Development of a position sensitive CsI(Tl) crystal array

  • Shi, Guo-Zhu;Chen, Ruo-Fu;Chen, Kun;Shen, Ai-Hua;Zhang, Xiu-Ling;Chen, Jin-Da;Du, Cheng-Ming;Hu, Zheng-Guo;Fan, Guang-Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.835-840
    • /
    • 2020
  • A position-sensitive CsI(Tl) crystal array coupled with the multi-anode position sensitive photomultiplier tube (PS-PMT), Hamamatsu H8500C, has been developed at the Institute of Modern Physics. An effective, fast, and economical readout circuit based on discretized positioning circuit (DPC) bridge was designed for the 64-channel multi-anode flat panel PSPMT. The horizontal and vertical position resolutions are 0.58 mm and 0.63 mm respectively for the 1.0 × 1.0 × 5.0 ㎣ CsI(Tl) array, and the horizontal and vertical position resolutions are 0.86 mm and 0.80 mm respectively for the 2.0 × 2.0 × 10.0 ㎣ CsI(Tl) array. These results show that the CsI(Tl) crystal array with low cost could be applied in the fields of medical imaging and high-resolution gamma camera.

Parallel Sensorless Speed Control using Power Angle for Dual SPMSMs Fed by a Single Inverter (단일 인버터 기반 두 대의 영구자석 동기전동기 병렬운전에서 전력각을 이용한 속도제어기법)

  • Kim, Kyung-Hoon;Yun, Chul;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1481-1487
    • /
    • 2017
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position. consequently, the position sensor is deemed essential for finding the rotor position. In this paper, we proposed a method that decides the magnitude of the load from the power angle of two motors due to the load variation and selects the motor to control through the sign function for the sensorless speed control without the position sensor. The results of simulation and experiment conducted verify the efficacy of the proposed method.

Experimental Study on the Unsteady Flow Characteristics for the Counter-Rotating Axial Flow Fan

  • Cho, L.S.;Lee, S.W.;Cho, J.S.;Kang, J.S.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.790-798
    • /
    • 2008
  • Counter-rotating axial flow fan(CRF) consists of two counter-rotating rotors without stator blades. CRF shows the complex flow characteristics of the three-dimensional, viscous, and unsteady flow fields. For the understanding of the entire core flow in CRF, it is necessary to investigate the three-dimensional unsteady flow field between the rotors. This information is also essential to improve the aerodynamic characteristics and to reduce the aerodynamic noise level and vibration characteristics of the CRF. In this paper, experimental study on the three-dimensional unsteady flow of the CRF is performed at the design point(operating point). Flow fields in the CRF are measured at the cross-sectional planes of the upstream and downstream of each rotor using the $45^{\circ}$ inclined hot-wire. The phase-locked averaged hot-wire technique utilizes the inclined hot-wire, which rotates successively with 120 degree increments about its own axis. Three-dimensional unsteady flow characteristics such as tip vortex, secondary flow and tip leakage flow in the CRF are shown in the form of the axial, radial and tangential velocity vector plot and velocity contour. The phase-locked averaged velocity profiles of the CRF are analyzed by means of the stationary unsteady measurement technique. At the mean radius of the front rotor inlet and the outlet, the phase-locked averaged velocity profiles show more the periodical flow characteristics than those of the hub region. At the tip region of the CRF, the axial velocity is decreased due to the boundary layer effect of the fan casing and the tip vortex flow. The radial and the tangential velocity profiles show the most unstable and unsteady flow characteristics compared with other position of rotors. But, the phase-locked averaged velocity profiles of the downstream of the rear rotor show the aperiodic flow pattern due to the mixture of the front rotor wake period and the rear rotor rotational period.

  • PDF

Research on Participation and Position Evaluation of Korean Manufacturing Global Value Chain: Based on the Comparative Analysis with China and the United States

  • Zhang, Fan;Su, Shuai
    • Journal of Korea Trade
    • /
    • v.25 no.2
    • /
    • pp.75-94
    • /
    • 2021
  • Purpose - This article will take the Korean manufacturing industry as an example to estimate Korea's global value chain status from the perspective of overall and sub-industry, hoping to provide a theoretical reference for Korean manufacturing to climb the global value chain. Design/methodology - Based on the WIOD data. The data is calculated by using MATLAB (2014a) coding. The data for 6 sectors are classified according to the International Standard Industrial Classification revision 3 (ISIC Rev. 3), the WIOD data are used to calculate and compare the position, participation and dynamics of the Korea, China and USA' manufacturing industry in the 1995-2016. Findings - The empirical results supported conclusions of the theoretical model. In the Korean GVC of electrical and optical sector, while stronger forward linkages than backward linkages to GVC are advantageous for an average advanced country, the benefits of downstream tasks are pronounced for non-advanced countries. And proved the correlation for an index to capture a country's upstream position or downstream position, it makes sense to compare that Korea's exports of intermediates in the same sector that are used by China and USA. Originality/value - The first is to re-examine the characteristics of South Korea's participation in global value chains under a more systematic and accurate theoretical framework, which provides a new empirical reference for related research; the second is to content covers of the manufacturing 6 sectors, so as to more completely describe the characteristics of Korean manufacturing's participation in global value chains; The value of this paper is providing empirical evidence of the effect of Korea's the GVC of manufacturing sectors. In the GVC of 6 sectors, first three have a higher position in the value chain and are in the upper middle and upper reaches of the GVC. The latter two have a low GVC position index, which has become the main sector that pulls down the overall position of Korea's manufacturing industry.

Investigate on the rate of change of CO concentration in a tunnel under changed position of the jet fans by using numerical method (제트 팬 가동위치에 따른 장대터널 내 CO 농도 변화율에 대한 전산해석)

  • Min, Jae-Hong;Kim, Dae-Hyun;Chung, Jin-Taek
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2765-2770
    • /
    • 2008
  • The purpose of tunnel ventilation system for long road tunnels is to keep certain levels of Visibility Index and the concentration of CO. Additional equipments such as jet fans are used in road tunnel to discharge pollutants in the road tunnel. The control algorism of tunnel ventilation system takes the value of sensors as input, and then gives the operation method of jet fans in tunnel as output. Information on the variation of CO concentration in tunnel when jet fans are running is needed to minimize their operation time. Numerical analysis is used in this paper because of the difficulty of conducting experiments under standard condition for ventilation of road tunnel. The concentration of CO has been calculated by using 3-dimensional CFD under transient condition with speed of cars, quantity of air ventilation, and the results for various operation position of jet fans are compared.

  • PDF

Control Methods of the VAV Air Handling Unit for the Required Outdoor Air Demand (변풍량 공조시스템의 요구외기량 확보를 위한 제어방식)

  • Han, Do-Young;Joo, Young-Duk;Kim, Jin;Lee, Jun-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.203-209
    • /
    • 2003
  • Control algorithms of an air handling unit by using the mixing box plenum pressures were developed and verified by experiments. Control algorithms developed for this study were the setpoint algorithms for the outdoor damper position, the outdoor/fixed plenum pressure, and the return/exhaust plenum pressure. The outdoor/fixed plenum pressure setpoint was used to control the bypass damper position, and the return/exhaust plenum pressure setpoint was used to control the return fan speed. Experimental results showed the good control of the required outdoor air demand. Therefore, setpoint algorithms developed for this study may effectively be applied for the control of the VAV air handling unit.

A Study on the Algorithm Development of End-point Position Tracking for Aerial Work Platform with Bend-linked Boom (굴절링크 붐을 갖는 장비의 끝점 좌표 추적 알고리즘 개발에 대한 연구)

  • Oh, Seok-Hyung;Hong, Yong
    • Journal of Power System Engineering
    • /
    • v.20 no.3
    • /
    • pp.64-73
    • /
    • 2016
  • In this research work, an algorithm development on tracking end-point of aerial work platform with jib profile and bend-linked boom was carried out to find the X, Y and Z direction value using coordinate transformation matrix. This matrix consists of device status value(length and angle) based on camera position axis, which are sent from device controller PLUS+1 by CAN protocol. These values are used to measure the distance and angle from the camera to the end-point. Using these distance and angle value, monitoring system controls FAN/TILT/ZOOM status of camera to get an adequate scene of workplace. This program was written in Java, C# and C for mobile device. These results provide the information to the aerial work device for secure operation.

A study on the development of a new sensorlss drive system for the brushless DC motors (브러시리스 직류 전동기용 새로운 센서리스 드라이브 개발에 관한 연구)

  • 장항제
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.591-595
    • /
    • 2000
  • In this paper we proposed a new sensorless drive system for the trapezoidal type brushless DC motor which does not use any mechanical position or speed sensor and applicable to the systems requiring a constant speed and torque such as Fan. For this a novel indirect rotor position sensing technique based on a detailed analysis of the terminal voltage characteristics is proposed in this paper. And a sensorless drive system for the brushless DC motor is implemented using a 87c196mc fo the main microprocessor and a power FET for the inverter. The experimental results will show the validity of the proposed indirect sensing method and the practical use of the sensorless drive

  • PDF

Sound Power Spectrum Guideline for a Refrigerator based on Subjective Evaluation (소비자 감성 평가를 통한 냉장고 Sound Power Spectrum Guideline)

  • Lee, Jin-Kyung;Jo, Kyoung-Sook;Lee, Jea-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.634-637
    • /
    • 2007
  • A weighted sound pressure level has been used to evaluate sounds test or sound quality test for a refrigerator up to present but the customer had different satisfactions of refrigerator sounds with different listening position. It means that there was a sound directivity caused by a position of fan or compressor. In this paper, we proposed a sound power spectrum guideline that represents total sound of refrigerator.

  • PDF

Sensorless Control Algorithm of a Surface Mounted PM Synchronous Motor Under Naturally Rotating by Load (외부부하에 의해 회전중인 표면부착형 영구자석동기전동기의 센서리스 제어 알고리즘)

  • Lee, Han-Sol;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.16-23
    • /
    • 2018
  • PM synchronous motor may be rotated to an arbitrary direction and speed by outside wind under natural condition in cases where the fan is applied outside, such as in vehicle radiators and outdoor air-conditioners. Sensorless controls that cannot detect rotor position requires additional sensorless control algorithm because a rotor is rotated by an external load. In this study, the sensorless control of a PM synchronous motor under naturally rotating condition is proposed. The natural rotation conditions are classified as forward high-speed rotation, reverse high-speed rotation, and low-speed rotation. Experiment results verify the performance of the sensorless control, including the rotor speed and position detection at natural rotation mode and switch to the closed-loop sensorless control.