• Title/Summary/Keyword: Portable equipment

Search Result 235, Processing Time 0.021 seconds

Basic Research of Non-Invasive Optical Transcutaneous pCo2 Gas Sensor & Analytic Equipment (비침습적 방법에 의한 광학식 Transcutaneous pCo2 가스센서 및 분석장치 개발을 위한 기초연구)

  • Kim, Do-Eok;Lee, Seung-Ha;Cho, Eun-Jong;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.258-263
    • /
    • 2004
  • In this study, we carried out a basic study for the development of optical transcutaneous $pCO_{2}$ gas sensor and analyzer using non-invasive method. The basic principle of $pCO_{2}$ measurement is adapted Beer lambert's law and embodied the system using NDIR method. This measuring system was composed of a IR lamp, a optical filter, a optical reaction chamber, pyroelectric sensor and a signal process. We measured $EtCO_{2}'s$ concentration in basis step instead of $pCO_{2}$ gas that can collect by inflicting heat in outer skin. We minimize the size of optical reaction chamber which takes up the largest volume, to make the portable sensor. We made optical reaction chamber in Si wafer using MEMS technology and the optical reaction chamber was shortened to 2 mm and we carried out an experiment. When we injected the $EtCO_{2}$ to the inside of the optical reaction chamber, we could confirm change of 4.6 mV. The system response time was within 2 second that is fairly fast.

Partial Discharge Measurement of Power Cables for Nuclear Power Plant (원자력발전소 전력케이블 부분방전 진단 사례)

  • Ha, Che-Wung;Ju, Kwang-Ho;Lim, Woo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1632-1638
    • /
    • 2011
  • Electric cables are one of the most important components in a nuclear power plant since they provide the power needed to operate electrical equipment. Despite their importance, cables typically receive little attention since they are considered passive, long-lived components that have been very reliable over the years when subjected to the environmental conditions for which they were designed. The operating experience reveals that a defect of the insulator or poor construction causes the initial failure of cable. However, the number of cable failures increase with plant aging, and these cable failures are occurring within the plants' 40-year licensed period. These cable failures have resulted in plant transients, shutdown, loss of safety functions or redundancy, entries into limiting conditions for operation, and challenges for plant operators. Therefore, diagnosis of MV cable installed in NPPs has become one of the most urgent issues in recent years. In accordance with PSR, condition maintenance for cables is also continuously required. Recently, HFPD tests have been widely performed to diagnose cable in the transmission and distribution cable system. However, on-line HFPD wasn't used in the NPPs because of the danger of plant shutdown, measurement sensitivity and application problems, etc. In this paper, HFPD measurement with portable device was performed to evaluate the integrity of the 4.16kV & 13.8kV cable lines. The test results show that HFPD is highly attractive to the diagnosis of MV cables in NPP by high detection sensitivity on-site.

Example Development of Medical Equipment Applying Power Electronics Technique (전력전자 기술을 응용한 의료장비 개발 사례)

  • 고종선;이태훈;김영일;김규겸;박병림
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.6
    • /
    • pp.524-530
    • /
    • 2002
  • A control of the body posture and movement is maintained by the vestibular system, vision, and proprioceptors. Afferent signals from those receptors are transmitted to the vestibular nuclear complex, and the efferent signals from the vestibular nuclear complex control the eye movement and skeletal muscle contract. The postural disturbance caused by loss of the vestibular function results in nausea, vomiting, vertigo and loss of craving for life. The purpose of this study is to develop a off-vertical rotatory system for evaluating the function of semicircular canals and otolith organs, selectively, and visual stimulation system for- stimulation with horizontal, vortical and 3D patterns. The Off-vortical axis rotator is composed of a comportable chair, a DC servo-motor with reducer and a tilting table controlled by PMSM. And a double feedback loop system containing a velocity feedback loop and a position feedback loop is applied to the servo controlled rotatory chair system. Horizontal, vertical, and 3D patterns of the visual stimulation for applying head mounted display are developed. And wireless portable systems for optokinetic stimulation and recording system of the eye movement is also constructed. The gain, phase, and symmetry is obtained from analysis of the eye movement induced by vestibular and visual stimulation. Detailed data were described.

Validity of Bioelectrical Impedance Analysis(BIA) in Measurement of Human Body Composition (소아 체지방 평가를 위한 생체 저항분석법의 타당성 연구 : 이중 에너지 방사선 흡수법과의 비교)

  • Kim, Hyung-Suck;Kim, Su-Yung
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.696-700
    • /
    • 2005
  • Propose : Body composition by bioelectrical impedance analysis(BIA) is a very useful method of analysing body composition. BIA is non-invasive, inexpensive, nonhazaedous and reproducible technique. The aim of this study was to determine the level of agreement between body composition measurement by BIA and dual-energy X-ray absorptiometry(DEXA). Methods : Data was examined in 100 children(male 58; female 42), who visited Pusan National Hospital. Weight(kg) and height(cm) were measured, and body compositions were analyzed with fat mass, lean body mass, body fat percent by BIA and DEXA methods. Results : Comparison of the DEXA and BIA methods showed highly statistically significant correlations in measurement of human body composition(fat mass, lean body mass, body fat percent). Conclusion : BIA should be considered as the method of choice in measurement of human body composition, since it's non-invasive, reliable, rapid, nonhazaedous and inexpensive, using portable equipment.

Simplified GIS Diagnostic SYSTEM (간이형 상시 GIS 진단장치)

  • Jeong, J.K.;Choi, Y.J.;Kang, C.I.;Jang, H.K.;Gwak, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.74-77
    • /
    • 2006
  • This research is focused on the development of GIS Diagnostic SYSTEM to prevent accidents beforehand by inspecting the internal defects of GIS (Gas Insulated Switchgear) which is a main power-facility for substations. GIS Diagnostic SYSTEM is categorized as 'Real time on-line test type' and 'Portable test type' depending on the types of testing, it uses PD(partial discharge) which mostly incurs in GIS internal defects, to inspect. As of now, mostly foreign equipments are imported for use due to the lack of the technology localization, and these are installed and operated on only some parts of highly-graded GIS power-facilities such as in 76skv or 345kv for its being expensive. Furthermore, other than foreign equipments being costly, it also has a weak point of very long unavailability in case of Diagnostic system break-down while using, because it takes a comparatively long period of corrective maintenance precesses. We have localized to develop personal real-time multi -functional GIS Diagnostic system which can test on all GIS power-facility comprehensively and economically therefore overcome all these problems mentioned above, a market expansion is expected from the decrease of price and replacing the import equipments in the future. As the equipment was developed to be Personal for the simple ways of installing and utilizing, it can be operated without any complex cable installation like other existing GIS Diagnostic system requires, therefore also decrease the cost of cable installation.

  • PDF

Design of A CMOS Composite Cell Analog Multiplier (CMOS 상보형 구조를 이용한 아날로그 멀티플라이어 설계)

  • Lee, Geun-Ho;Choe, Hyeon-Seung;Kim, Dong-Yong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.2
    • /
    • pp.43-49
    • /
    • 2000
  • In this paper, the CMOS four-quadrant analog multipliers for low-voltage low-power applications ate presented. The circuit approach is based on the characteristic of the LV(Low-Voltage) composite transistor which is one of the useful analog building blocks. SPICE simulations are carried out to examine the performances of the designed multipliers. Simulation results are obtained by 0.6${\mu}{\textrm}{m}$ CMOS parameters with 2V power supply. The LV composite transistor can easily be extended to perform a four-quadrant multiplication. The multiplier has a linear input range up to $\pm$0.5V with a linearity error of less than 1%. The measured -3㏈ bandwidth is 290MHz and the power dissipation is 373㎼. The proposed multiplier is expected to be suitable for analog signal processing applications such as portable communication equipment, radio receivers, and hand-held movie cameras.

  • PDF

Development of Obesity Management Application Based on Android -Focused on BMI and Calculate Momentum- (안드로이드 기반 비만 관리 애플리케이션 개발 -BMI 및 운동량 산출을 중심으로-)

  • Song, Kyung-Chul;Hyun, Dong-Lim;Kim, Eun-Kil;Kim, Jong-Hoon
    • 한국정보교육학회:학술대회논문집
    • /
    • 2011.01a
    • /
    • pp.265-270
    • /
    • 2011
  • This paper is the study about application development for management obesity and personal health matters systematically based on Android smart phone system. Growing obesity problem for students organized by the lack of a device or program to manage at home has been favored as a serious problem. Currently developed smart phones has come into wide use by portable features and many applications. And to support populations of these features smart phones will be available for obesity management in your home without any equipment using. Accordingly, this paper is the study about application development for management obesity for growing students at home based on the latest smart phone platform Android.

  • PDF

Development of Baekje cultural tourism contents by utilizing portable VR glasses (휴대용 가상현실 안경을 접목한 백제문화 관광 콘텐츠 개발)

  • Kang, Byoung-Gil;Lee, Wan-Bok;Ryu, Seuc-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.1
    • /
    • pp.317-323
    • /
    • 2018
  • Although various kinds of VR services are being carried out in the tourism field, The virtual reality experiences are still costly, since they could be realized in a limited space with some kinds of expensive equipment such as HMD. In this study, we propose a mobile virtual reality tourism experience using an easy and simple Google card board and user's smartphone because most tourist sites are outdoors and most of users like enjoying sightseeing and experience at the same time. For this purpose, we constructed a system that provides tourist information in real time employing both the IoT and VR techniques. Especially we develpoed a tourism contents for the UNESCO World Heritage Communities of Baekje Historical Site and Songsanri Tumulus. In addition, we virtually restored the royal palace in Gongju and confirmed the historical experience by VR flatform could be popular with people.

Development of a Portable Automatic Auditory Response Tester for Hearing Loss Screening (난청감별을 위한 휴대용 자동 청성반응 검사기의 개발)

  • Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.38-45
    • /
    • 2012
  • If an infant with congenital hearing loss is diagnosed in good time and get proper treatment as soon as possible, treatment effect could be maximized and the social costs could be considerably reduced. For these reasons, the medical equipment to screen hearing impairment objectively is needed. The ABR(auditory brainstem response) is typical diagnostic tools for this purpose but there are drawbacks in sense that it does not have frequency specificity and shows hearing information of usually high frequency band. The ASSR(auditory steady-state response) is excellent in frequency specificity, but the rate of wrong diagnosis is slightly high. In this study, we proposed the system which can measure both the ABR and the ASSR, and can show the objective and quantitative indices(Fsp and F-test). It was designed to allow various tests without hardware modification by minimizing hardware components and by increasing software roles. The objective assessment of the developed system was evaluated by experiments with 10 normal persons.

Performance Evaluation of Low Rate Wireless Home Network Embedded DSSS System (저속 무선 홈 네트워크 임베디드 DSSS 시스템의 성능 평가)

  • Roh, Jae-Sung
    • Journal of Digital Contents Society
    • /
    • v.7 no.2
    • /
    • pp.103-108
    • /
    • 2006
  • Short-range wireless communication and networking technologies are becoming increasingly important in enabling useful mobile applications. for example, ZigBee technology is expected to provide low cost and low power connectivity for equipment that needs battery life as long as several months to several years. In addition, ZigBee can be implemented in mesh networks larger than is possible with Bluetooth. The main features of this ZigBee standard are network flexibility, low cost, very low power consumption, and low data rate in an adhoc self-organizing network among fixed, portable and moving devices. Home network/Home automation is one of the key market areas for Zigbee, with an example of a simple network This paper investigates the effect of short range wireless channel on the performance of Zigbee system and DSSS-BPSK signal transmission in AWGN, interference and Rician fading environments. And we investigate performance degradation due to interference and fading effects in short range wireless channel. In particular, the impacts of the fading and interference level on the bit error probability is shown in BER performance figures.

  • PDF