• Title/Summary/Keyword: Porcelain insulators

Search Result 125, Processing Time 0.029 seconds

Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test (트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가)

  • 조한구;안명상;한세원;허종철;이운용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF

Prediction of Flashover and Pollution Severity of High Voltage Transmission Line Insulators Using Wavelet Transform and Fuzzy C-Means Approach

  • Narayanan, V. Jayaprakash;Sivakumar, M.;Karpagavani, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1677-1685
    • /
    • 2014
  • Major problem in the high voltage power transmission line is the flashover due to polluted ceramic insulators which leads to failure of equipments, catastrophic fires and power outages. This paper deals with the development of a better diagnostic tool to predict the flashover and pollution severity of power transmission line insulators based on the wavelet transform and fuzzy c-means clustering approach. In this work, laboratory experiments were carried out on power transmission line porcelain insulators under AC voltages at different pollution conditions and corresponding leakage current patterns were measured. Discrete wavelet transform technique is employed to extract important features of leakage current signals. Variation of leakage current magnitude and distortion ratio at different pollution levels were analyzed. Fuzzy c-means algorithm is used to cluster the extracted features of the leakage current data. Test results clearly show that the flashover and pollution severity of power transmission line insulators can be effectively realized through fuzzy clustering technique and it will be useful to carry out preventive maintenance work.

A Random Forest Model Based Pollution Severity Classification Scheme of High Voltage Transmission Line Insulators

  • Kannan, K.;Shivakumar, R.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.951-960
    • /
    • 2016
  • Tower insulators in electric power transmission network play a crucial role in preserving the reliability of the system. Electrical utilities frequently face the problem of flashover of insulators due to pollution deposition on their surface. Several research works based on leakage current (LC) measurement has been already carried out in developing diagnostic techniques for these insulators. Since the LC signal is highly intermittent in nature, estimation of pollution severity based on LC signal measurement over a short period of time will not produce accurate results. Reports on the measurement and analysis of LC signals over a long period of time is scanty. This paper attempts to use Random Forest (RF) classifier, which produces accurate results on large data bases, to analyze the pollution severity of high voltage tower insulators. Leakage current characteristics over a long period of time were measured in the laboratory on porcelain insulator. Pollution experiments were conducted at 11 kV AC voltage. Time domain analysis and wavelet transform technique were used to extract both basic features and histogram features of the LC signal. RF model was trained and tested with a variety of LC signals measured over a lengthy period of time and it is noticed that the proposed RF model based pollution severity classifier is efficient and will be helpful to electrical utilities for real time implementation.

The Development and Field Test of DC FRP Support Insulator Prototype (직류용 FRP 지지애자 개발 및 현장설치 적응시험)

  • Sim, Jae-Suk;Kim, Yoon-Sik;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1979-1983
    • /
    • 2011
  • FRP(Fiber Reinforced Plastic) support insulators for DC(direct current) were developed and their electrical and mechanical characteristics were investigated. Electrical tests were carried out to measure flashover voltages under common use frequency condition. Tensile and bending tests were performed for the mechanical characteristics. The test results showed that FRP support insulators have superior voltage resistances and strengths to porcelain insulators. Field test also is carried out to measure adaptation and to compensate the defect. The test result showed that a new product has no defect in electrical and mechanical.

  • PDF

A Study Performance and Design Compositor Insulator for 170kV D/S (170kV급 단로기용 Composite Insulator 설계 및 특성 연구)

  • Cho, H.G.;Park, K.H.;Han, D.H.;Yoon, M.S.;Jin, S.Y.;Song, H.S.;Lee, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.252-254
    • /
    • 2003
  • Recently composite insulators are being used for outdoor high voltage applications. Composite insulators for transmission line have significant advantages over porcelain insulators, especially for ultra-high voltage. Their advantages are light weight, vandalism resistance, and hydrophobicity. We developed a 170kV high reliable vertical break disconnector with good long term electrical and mechanical performance which was achieved by the improvement of electrical performance and light weight. We discuss the outline of the development and the product.

  • PDF

Tracking Resistance and UV Degradation Property of Polymeric Insulating Materials by Cross-Link Time (가교시간에 따른 고분자 재료의 트래킹성과 자외선 열화특성)

  • 천종욱;이운용;조한구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.447-450
    • /
    • 2002
  • Recently polymeric insulators and arresters are being used for outdoor high voltage applications. Polymeric insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymeric insulator kind are a relatively new technology, but their expected life is still unknown. In this paper, the material property for polymeric insulating material such as silicone rubber and EPBM is investigated by cross-link time and the relation between tracking resistance and W resistance is analyzed by IEC 60587 and W aging experiment.

  • PDF

Development of 132kV XLPE Cable Composite Bushing EB-A (132kV XLPE Cable용 Composite Bushing 기중종단접속함 개발)

  • Kim, J.H.;Oh, E.J.;Kim, K.Y.;Park, J.K.;Jeoung, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.547-549
    • /
    • 2000
  • Silicone insulators have many advantages over porcelain insulators. Especially silicone insulators have good characteristics of impact hardness, surface insulation, ease of processing, mass productivity and don't have risk of bombardment and vandalism. Recently insulation part made by silicone are becoming widely used. In this paper we introduce the development of Sealing End for 132kV XLPE cable with silicone composite hollow insulator and the adoption of it to a actual transmission line in abroad. This paper contains of design procedure, structure, electrical performance of it.

  • PDF

Study on design technique of high voltage insulators in contaminated environment using finite element method. (유한요소법에 의한 고압절연애자의 오손특성설계법의 개발)

  • 황영문;이일천
    • 전기의세계
    • /
    • v.29 no.10
    • /
    • pp.653-659
    • /
    • 1980
  • The paper describes a new technique for the shape design of a bell-type porcelain locke insulator in contaminated environment. Early studies on the contamination performance of insulators indicated the need for an improvable shape to provide adequate insulation strength at normal operating voltages. In this paper, under lightly and heavily contaminated site severity, the variation of voltage distribution to leakage path at insulator surfaces analyzed by the complex admittance matrix using finite element method. By this results, the improvement of shape of insulators could be approached to the available condition in contaminated environments. In applicating to compare a standard disc type with a fog disc type insulator, this design technique is valid.

  • PDF

Assessment Technique and Aging Test for EHV Porcelain Insulators (송전용 자기재 애자의 열화시험 평가기술)

  • Han, S.W.;Cho, H.G.;Park, K.H.;Jung, G.C.;Lee, D.I.;Choi, I.H.;Shin, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.480-483
    • /
    • 2002
  • This paper through shift norm of insulator and research by accident prevention countermeasure special skill authoritativeness verification of insulator and Long Term aging factor for power transmission analysis and evaluate and prove quality of insulator wish to. Assessment technique by aging of own porcelain insulator observes ageing factor for reciprocity comparison through several examinations. Through cool and heat accelerated Aging test, can measure the leakage current change amount that ensue to each Cycle. Can confirm own blazing fire factor as distribution freshness that ensue in HRB Test's hardness value.

  • PDF

Study on Long-term Deterioration Properties of Porcelain Insulators with Aluminous System (알루미나계 자기애자의 장기 피로특성에 관한 연구)

  • Han, Se-Won;Cho, Han-Goo;Lee, Dong-Il;Cho, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.562-563
    • /
    • 2005
  • In case of aged porcelain, the failure in basic performance tests happened in cool-heat tests. Based on this characteristic, we studied the method predicting failure phenomena through more severe accelerated cool-heat ageing and accelerating thermal mechanical performance tests. Test results indicated that the thermal stress by temperature gradient was more severe parameter than thermal stress by quenching cycles within a category of standard or accelerating methods. And there is no the deterioration of statistic strength, but the deterioration of strength according to accelerating tests is serious.

  • PDF