분전반 내 차단기의 접속불량에 의한 이상발열에 관한 연구 (A Study on the Abnormal Heating of Circuit Breaker in Panel Board by Poor Connection)

  • 김향곤;김동우;최효상;최용성;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.10-14
    • /
    • 2008
  • In this paper, abnormal heating of circuit breaker in panel board by poor connection was studied. Firstly, calculation method of contact resistance shown in IEC 60943 was examined. Secondly, concerning abnormal heating of circuit breaker in panel board, field measurements were performed. Field measurements showed that locally abnormal heating by poor connection could be detected, therefore, in that case, immediate action was needed. Finally, experiments regarding abnormal heating between terminal of circuit breaker and electric wire were conducted. The results showed that abnormal heating above $180^{\circ}C$ was measured. Also, in the results of analysis of electrical waveforms according to load current, voltage drop occurred around poor connection, and the oxide was generated according to mechanical vibration. In order to prevent electrical disaster caused by poor connection, adequate torque should be applied to electrical connection, and periodic check-ups are needed.

  • PDF

5.5kW이하의 소형분쇄기 차단기 접속부의 접촉불량에 의한 전압강하 및 열적 특성 분석 (Analysis of Voltage Drop and Thermal Characteristics for Poor Connections at Electrical Connector of Circuit Breaker of Small Size Pulverizer below 5.5kW)

  • 김상철
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.26-31
    • /
    • 2015
  • This paper describes the characteristics of voltage drop and thermal for poor connection on electrical connector of circuit breaker in control box of small size pulverizer. In order monitor, we did the changes of RMS in voltage and temperature value with video and made normal state over $2.5N{\cdot}m$ and poor connections state below $0.2N{\cdot}m$ by screw gage. In case of voltage signal, the voltage drop was increased when the current was increased due to poor connections. In case of temperature signal, the temperature difference indicates ten times at 5A and fourteen times at 15A in the normal state. According to increase thermal energy, the insulation of electrical wiring and connector of circuit breaker can be carbonized. The results of this study will be useful to the development of preventive devices and system for electric fire by poor connection at small size pulverizer.

열화상 분석을 이용한 전력시스템의 안전진단에 관한 연구 (A Study on the Safety Diagnosis for Electric Power Systems Using Thermal Imaging Analysis)

  • 유병열;김찬오
    • 한국안전학회지
    • /
    • 제26권2호
    • /
    • pp.26-31
    • /
    • 2011
  • In this paper, the safety diagnosis using thermal image analysis is described for power equipments. The conventional three-phase comparison method has only provided the results of thermal comparison for the equipments. The proposed method defines the conditions of poor connection by visual checks, and supports the criteria with each thermal rise step. As a result, the thermal difference from $5^{\circ}C$ to $10^{\circ}C$ meant the warning state. In addition, the thermal difference more than $10^{\circ}C$ meant that the connection status was unbalanced. In this case, the countermeasure might be the internal load distribution. If the thermal difference more than $20^{\circ}C$ is observed, it means a hot spot at the poor connection. If the hot spot is observed all over the surface, its cause was the unbalanced load, which made the conductive parts discolored and raised the possibility of oxidization or $Cu_2O$ generation. This diagnostic technology employing thermal image analysis method can be directly applied in the field and ensures the safety of equipments.

EXACTNESS THEOREM AND POOR M-COSEQUENCES

  • Khashyarmanesh, K.;Salarian, Sh.
    • 대한수학회지
    • /
    • 제34권4호
    • /
    • pp.949-957
    • /
    • 1997
  • The purpose of this paper is to establish connection between certain complex of modules of generalized fractions and the concept of cosequence in commutative algebra. The main theorem of the paper leads to characterization, in terms of modules of generalized fractions, of regular (co) sequences.

  • PDF

저압용 누전차단기 접속부의 발열 및 금속 조직 분석에 관한 연구 (A Study on the Analysis of Heat and Metallurgical Structure of Connection Parts for Residual Current Protective Devices)

  • 최충석;송길목;김동욱;김동우;김영석
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.57-63
    • /
    • 2004
  • 본 연구에서는 저압용 누전차단기 접속단자에서의 접촉압력에 따른 발열특성을 조사하고 차단기 단자와 전선에 접촉 불량이 발생했을 때의 전압, 전류파형과 산화물 증식 등을 분석하였다. 차단기 단자와 전선에 접촉압력이 가해지지 않았을 때는 접촉저항증가로 열이 발생하고 금속표면에 산화 막이 형성되었다. 이때 단자 외부 절연물의 온도는 접촉 불량에 의해 급격하게 상승하며 단자내부에서 미세한 불꽃과 연속적인 방전음이 발생하였다. 단자내부도체와 접속전선 접촉면에서 기계적 진동에 의한 접촉 불량이 발생했을 때, 접촉면에서 산화물이 증식되고 발열온도는 869℃이상으로 상승하여 전기재해의 위험이 높음을 알 수 있었다.

Numerical cyclic behavior of T-RBS: A new steel moment connection

  • Ataollahi, Saeed;Banan, Mohammad-Reza;Banan, Mahmoud-Reza
    • Steel and Composite Structures
    • /
    • 제21권6호
    • /
    • pp.1251-1264
    • /
    • 2016
  • After observing relatively poor performance of bolted web-welded flange beam-to-column connections during 1994 Northridge earthquake, various types of connections based on two concepts of: (i) strengthening the connection; and (ii) weakening the beam ends were proposed. Among these modified or newly proposed connections, bolted T-stub connection follows the concept of strengthening. One of the connections with the idea of weakening the beam ends is reduced beam section (RBS). In this paper, finite element simulation is used to study the cyclic behavior of a new proposed connection developed by using a combination of both mentioned concepts. Investigated connections are exterior beam-to-column connections designed to comply with AISC provisions. The results show that moment capacity and dissipated energy of the new proposed connection is almost the same as those computed for a T-stub connection and higher than corresponding values for an RBS connection.

Combination-mode BLE Device Profile for Connection & Non-connection Methods

  • Jiang, Guangqiu;Joe, Inwhee
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2016년도 춘계학술발표대회
    • /
    • pp.897-899
    • /
    • 2016
  • In recent years, BLE technology has received extensive attention and has been applied to all aspects of life. The existing BLE device has two methods, one is the connection method, and the other is a non-connection method. The representative profile of the connection method is the proximity file. The most typical example of Non-connection method BLE device is a beacon. However, they are both independent and have their own shortcomings. Connection method device can provide service for only one user, others can't use. Security performance of Non-connection method BLE device is poor and the device can't be controlled by the user. In this paper, a combination-mode BLE device profile design scheme is presented, which combines with the previous two methods, and solves the defaults. And We define a dual purpose advertising package that can be used in a normal environment as well as in a disaster environment. Finally, a unidirectional Control idea is proposed. Through performance evaluation, we found that the device has strong stability and low power consumption.

배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축 (Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire)

  • 김두현;김성철;이종호;강동규
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.

상수도강관 용접접합의 방법별 비교분석 (The Comparison Analysis of Welding Techniques in Water Distribution Steel Pipes)

  • 김응석;정원식;김성표
    • 한국산학기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.2859-2865
    • /
    • 2011
  • 본 연구에서는 상수도관의 도 송수관등 대형관(700mm 이상)에 주로 사용되고 있는 도복장강관의 품질 및 시공, 유지관리에 영향을 미치는 용접접합의 현황을 조사 분석하고 용접접합의 개선방안에 대하여 연구하였다. 이를 위해 강관의 사용현황 등의 문제점을 조사하고 용접접합별 특성, 그리고 수동 및 자동 용접접합을 비교 분석하여 기술적, 경제적으로 효과적인 방안을 제시하고자 하였다. 본 연구에서 비교 분석한 용접접합별 특성 검토 결과, 상수도 관로의 관경 700mm - 3,000mm의 현장 시공시 자동용접공법이 수동용접공법에 비해 순공사비 대비 평균 9% 절감되며, 용접공정만 비교시에는 평균 13.5% 이상 절감될 것으로 판단된다. 특히, KS상 강관 진원도에 대한 허용치가 크며 대부분 겹치기 이음으로 되어있는 국내 현실에서 작업환경이 열악한 경우 진원확보를 위한 시간이 무한정 소요될 수 있어 실제적인 절감액은 더욱 차이를 보일 것으로 사료된다.

커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석 (Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector)

  • 김상철;김두현;강신욱
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.