• Title/Summary/Keyword: Poor connection

Search Result 138, Processing Time 0.025 seconds

A Study on the Abnormal Heating of Circuit Breaker in Panel Board by Poor Connection (분전반 내 차단기의 접속불량에 의한 이상발열에 관한 연구)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Choi, Hyo-Sang;Choi, Yong-Sung;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.10-14
    • /
    • 2008
  • In this paper, abnormal heating of circuit breaker in panel board by poor connection was studied. Firstly, calculation method of contact resistance shown in IEC 60943 was examined. Secondly, concerning abnormal heating of circuit breaker in panel board, field measurements were performed. Field measurements showed that locally abnormal heating by poor connection could be detected, therefore, in that case, immediate action was needed. Finally, experiments regarding abnormal heating between terminal of circuit breaker and electric wire were conducted. The results showed that abnormal heating above $180^{\circ}C$ was measured. Also, in the results of analysis of electrical waveforms according to load current, voltage drop occurred around poor connection, and the oxide was generated according to mechanical vibration. In order to prevent electrical disaster caused by poor connection, adequate torque should be applied to electrical connection, and periodic check-ups are needed.

  • PDF

Analysis of Voltage Drop and Thermal Characteristics for Poor Connections at Electrical Connector of Circuit Breaker of Small Size Pulverizer below 5.5kW (5.5kW이하의 소형분쇄기 차단기 접속부의 접촉불량에 의한 전압강하 및 열적 특성 분석)

  • Kim, Sang Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.26-31
    • /
    • 2015
  • This paper describes the characteristics of voltage drop and thermal for poor connection on electrical connector of circuit breaker in control box of small size pulverizer. In order monitor, we did the changes of RMS in voltage and temperature value with video and made normal state over $2.5N{\cdot}m$ and poor connections state below $0.2N{\cdot}m$ by screw gage. In case of voltage signal, the voltage drop was increased when the current was increased due to poor connections. In case of temperature signal, the temperature difference indicates ten times at 5A and fourteen times at 15A in the normal state. According to increase thermal energy, the insulation of electrical wiring and connector of circuit breaker can be carbonized. The results of this study will be useful to the development of preventive devices and system for electric fire by poor connection at small size pulverizer.

A Study on the Safety Diagnosis for Electric Power Systems Using Thermal Imaging Analysis (열화상 분석을 이용한 전력시스템의 안전진단에 관한 연구)

  • Yu, Byeong-Yeol;Kim, Chan-O
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.26-31
    • /
    • 2011
  • In this paper, the safety diagnosis using thermal image analysis is described for power equipments. The conventional three-phase comparison method has only provided the results of thermal comparison for the equipments. The proposed method defines the conditions of poor connection by visual checks, and supports the criteria with each thermal rise step. As a result, the thermal difference from $5^{\circ}C$ to $10^{\circ}C$ meant the warning state. In addition, the thermal difference more than $10^{\circ}C$ meant that the connection status was unbalanced. In this case, the countermeasure might be the internal load distribution. If the thermal difference more than $20^{\circ}C$ is observed, it means a hot spot at the poor connection. If the hot spot is observed all over the surface, its cause was the unbalanced load, which made the conductive parts discolored and raised the possibility of oxidization or $Cu_2O$ generation. This diagnostic technology employing thermal image analysis method can be directly applied in the field and ensures the safety of equipments.

EXACTNESS THEOREM AND POOR M-COSEQUENCES

  • Khashyarmanesh, K.;Salarian, Sh.
    • Journal of the Korean Mathematical Society
    • /
    • v.34 no.4
    • /
    • pp.949-957
    • /
    • 1997
  • The purpose of this paper is to establish connection between certain complex of modules of generalized fractions and the concept of cosequence in commutative algebra. The main theorem of the paper leads to characterization, in terms of modules of generalized fractions, of regular (co) sequences.

  • PDF

A Study on the Analysis of Heat and Metallurgical Structure of Connection Parts for Residual Current Protective Devices (저압용 누전차단기 접속부의 발열 및 금속 조직 분석에 관한 연구)

  • Choi Chung-Seog;Shong Kil-Mok;Kim Dong-Ook;Kim Dong-Woo;Kim Young-Seok
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.57-63
    • /
    • 2004
  • We investigated heat properties of connection terminal in residual current protective devices(RCD) according to contact pressure for low voltage appliance. And we analyzed voltage and current waveform and oxide propagation when the poor-contact happened between terminal and wire. When contact pressure between terminal and connection wire was not applied, the heat was generated and an oxide was formed on the surface of the wire. The temperature of the insulation surrounding terminal was ascended sharply by poor-contact, micro-sparks and continuous arc sound happened in interior terminal. When the poor-contact by vibration occurred inner conductor of terminal and wire, an oxide was propagated on contact surface and the temperature was increased at 869℃. Thus, we found that the risk of electrical disaster is high in terminal and connection wire parts.

Numerical cyclic behavior of T-RBS: A new steel moment connection

  • Ataollahi, Saeed;Banan, Mohammad-Reza;Banan, Mahmoud-Reza
    • Steel and Composite Structures
    • /
    • v.21 no.6
    • /
    • pp.1251-1264
    • /
    • 2016
  • After observing relatively poor performance of bolted web-welded flange beam-to-column connections during 1994 Northridge earthquake, various types of connections based on two concepts of: (i) strengthening the connection; and (ii) weakening the beam ends were proposed. Among these modified or newly proposed connections, bolted T-stub connection follows the concept of strengthening. One of the connections with the idea of weakening the beam ends is reduced beam section (RBS). In this paper, finite element simulation is used to study the cyclic behavior of a new proposed connection developed by using a combination of both mentioned concepts. Investigated connections are exterior beam-to-column connections designed to comply with AISC provisions. The results show that moment capacity and dissipated energy of the new proposed connection is almost the same as those computed for a T-stub connection and higher than corresponding values for an RBS connection.

Combination-mode BLE Device Profile for Connection & Non-connection Methods

  • Jiang, Guangqiu;Joe, Inwhee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.897-899
    • /
    • 2016
  • In recent years, BLE technology has received extensive attention and has been applied to all aspects of life. The existing BLE device has two methods, one is the connection method, and the other is a non-connection method. The representative profile of the connection method is the proximity file. The most typical example of Non-connection method BLE device is a beacon. However, they are both independent and have their own shortcomings. Connection method device can provide service for only one user, others can't use. Security performance of Non-connection method BLE device is poor and the device can't be controlled by the user. In this paper, a combination-mode BLE device profile design scheme is presented, which combines with the previous two methods, and solves the defaults. And We define a dual purpose advertising package that can be used in a normal environment as well as in a disaster environment. Finally, a unidirectional Control idea is proposed. Through performance evaluation, we found that the device has strong stability and low power consumption.

Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire (배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kang, Dong-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.

The Comparison Analysis of Welding Techniques in Water Distribution Steel Pipes (상수도강관 용접접합의 방법별 비교분석)

  • Kim, Eung-Seok;Jeong, Won-Sik;Kim, Sung-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2859-2865
    • /
    • 2011
  • The welded connection is known as an essential factor for establishing qualified construction and/or maintenance of wrapped steel pipe. In this study, welded connection conditions in the coated pipes with large diameter (over 700 mm) in Korea water distribution systems were estimated for suggesting technically and economically available welded connection method. For the study analysis, current steel pipe usage and accident cases were investigated. In addition, the characteristics of each welded connection method and automatic or manual connection techniques were also compared and estimated. As results, automatic welded connection method is superior than manual welded connection method in aspect of pure construction cost (average 9%) or pure welded connection cost (average 13.5%). When the poor welding-working situations in Korea are considered such as high tolerance of out-of-roundness in KS regulation, a number of lap joint welded connections, the real cost benefits of automatic welded connection should be much higher than those of manual welded connections.

Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector (커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석)

  • Kim, Sang-Chul;Kim, Doo Hyun;Kang, Shin Uk
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.