• Title/Summary/Keyword: Polymethyl methacrylate

Search Result 188, Processing Time 0.038 seconds

Estimation of Computed Tomography Dose in Various Phantom Shapes and Compositions (다양한 팬텀 모양 및 재질에 따른 전산화단층촬영장치 선량 평가)

  • Lee, Chang-Lae
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • The purpose of this study was to investigate CTDI (computed tomography dose index at center) for various phantom shapes, sizes, and compositions by using GATE (geant4 application for tomographic emission) simulations. GATE simulations were performed for various phantom shapes (cylinder, elliptical, and hexagonal prism PMMA phantoms) and phantom compositions (water, PMMA, polyethylene, polyoxymethylene) with various diameters (1-50 cm) at various kVp and mAs levels. The $CTDI_{100center}$ values of cylinder, elliptical, and hexagonal prism phantom at 120 kVp, 200 mAs resulted in 11.1, 13.4, and 12.2 mGy, respectively. The volume is the same, but $CTDI_{100center}$ values are different depending on the type of phantom. The water, PMMA, and polyoxymethylene phantom $CTDI_{100center}$ values were relatively low as the material density increased. However, in the case of Polyethylene, the $CTDI_{100center}$ value was higher than that of PMMA at diameters exceeding 15 cm ($CTDI_{100center}$ : 35.0 mGy). And a diameter greater than 30 cm ($CTDI_{100center}$ : 17.7 mGy) showed more $CTDI_{100center}$ than Water. We have used limited phantoms to evaluate CT doses. In this study, $CTDI_{100center}$ values were estimated and simulated by GATE simulation according to the material and shape of the phantom. CT dosimetry can be estimated more accurately by using various materials and phantom shapes close to human body.

PMMA MICROSPHERES (ARTECOLL$^{(R)}$) INJECTION FOR NASAL RIDGE AUGMENTATION IN THE ORTHOGNATHIC SURGERY (악교정수술환자에서 폴리메틸메터크릴레이트(아테콜$^{(R)}$) 주입을 통한 융비술)

  • Ok, Yong-Ju;Kim, Myung-Jin;Paeng, Jun-Young;Myoung, Hoon;Hwang, Soon-Jung;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.4
    • /
    • pp.329-334
    • /
    • 2005
  • Polymethyl-methacrylate(PMMA; Artecoll$^{(R)}$) microspheres suspended 1 : 3 in a 3.5% collagen solution has been used as an injectable implant for long lasting correction of wrinkles and minor skin defects. The patients with mandibular prognathism have increased necessity for nasal augmentation. Usually these patients usually get an additional rhinoplasty after orthognathic surgery. The purpose of this study is to evaluate the result of PMMA injection for nasal ridge augmentation simultaneously with the orthognathic surgery. PMMAs were injected to the nasal dorsum of 13 patients with mandibular prognathism to augment the nasal ridge at the end of the orthognathic surgery. The cephalometric X-ray and clinical facial photograph were taken at 2, 4 and 6 months after operation. Using S-N line, we calculated the change of soft tisuue on the nasal ridge and also investigated the degree of patients satisfaction at 6 months after operation. Most of the patients were satisfied with their nasal ridge height status from moderate to good degree. The average amount of nasal ridge augmentation was $1.4{\pm}0.5$ mm immediately after operation, $1.2{\pm}0.4$ mm at 2 months after operation. The postoperative nasal ridge height seemed to be remained stable after 2 months. Intraoperative PMMA injection is considered to be simple and effective technique which can be used for the minor augmentation of nasal ridge in the orthognathic patients.

Stabilization using Screws, Wire, and PMMA for Traumatic Cervical Fracture in a Maltese Dog (말티즈 견에서 Screw, Wire와 PMMA를 사용한 외상성 경추 골절의 안정화)

  • Kim, KeunYung;Kim, Minkyung;Park, Ji-Hun;Shin, Jeong-In;Kim, Junsu;Jang, Yun-Seol;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.519-522
    • /
    • 2014
  • A 2-year-old, 2 kg Maltese dog was evaluated for progressive tetraparesis and neck pain. The dog had been treated with steroids for the preceding 2 weeks after unknown trauma but was deteriorating progressively and had become tetraparetic. The dog was presented with a non-ambulatory tetraparesis. Radiographic and computed tomographic examinations revealed a transverse C2 fracture with subluxation of the atlantoaxial joint and C2-C3. In addition, hydrocephalus was observed on magnetic resonance imaging. Stabilization of C1-C3 using screws, wires, and polymethyl methacrylate (PMMA) was performed. Application of ventral screws, wires, and PMMA resulted in improvement of the clinical signs after 4 weeks, and the dog could walk as before the tetraparesis 6 weeks after the operation. This stabilization method is an effective surgical treatment for management of cervical instability.

A comparison of chlorhexidine release rate from three polymeric controlled release drug prototypes (제어방출형 소독제의 약물전달 체로 사용된 폴리머 유형에 따른 클로르헥시딘 제어 방출속도 비교)

  • Bok Young-Bin;Lee Doug-Youn;Lee Chang-Young;Kim Kyung-Nam;Kum Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.548-552
    • /
    • 2004
  • Intracanal disinfection of infected root canal is one of important treatment procedure. This in vitro study aimed to evaluate whether the surface polymers of controlled release drug (CRD) can effectively control the release rate of chlorhexidine for root canal disinfection. Four CRD prototypes were prepared: Group A (n=12); The core device (absorbent paper point) was loaded with 40% CHX solution as control. Group B (n=12); same as group A, but the device was coated with chitosan. Group C (n=12); same as group A and then coated three times with 5% PMMA. Group D (n=12); same as group A and then coated three times with 3% PLGA. All CRD prototypes were soaked in 3 mL distilled water for experimental periods and the concentrations of released CHX from each CRD prototype were determined using a UV spectrophotometer. Results showed that release rate of CHX were the greatest in the non-coated group (control group), followed by the chitosan-coated group, the PLGA-coated group, and the PMMA-coated group (P < 0.05). This data indicate that surface polymers can control the release rate of CHX from the CRD prototypes.

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report (디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례)

  • Jeong, Dae Gil;Oh, Kyung Chul;Shim, June Sung;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.397-404
    • /
    • 2019
  • Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.

Analysis on Insulation of Wind Environment and Greenhouse Cover Materials Insulation for Advanced Greenhouse Energy Design in Saemangeum Reclaimed Land (새만금 간척지 첨단온실 에너지 설계를 위한 풍환경 및 온실 피복재의 영향 분석)

  • Hyo-Jae Seo;Il-Hwan Seo;Deuk-ha Noh;Haksung Lee
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.57-63
    • /
    • 2023
  • The external weather conditions including temperature and wind speed in the Saemangeum reclaimed land is different from that of the inland, affecting the internal environment of the greenhouse. Therefore, it is important to select an appropriate covering material considering the insulation effect according to the type and characteristics of the covering material considering the weather condition in the Saemangeum reclaimed land. A hexahedral insulation chamber was designed to evaluate the insulation efficiency of each glass-clad material in the outside weather condition in reclaimed land. In order to evaluate the insulation effect of each covering material, a radiator was installed and real-time power consumption was monitored. 16-mm PC (polycarbonate), 16-mm PMMA (polymethyl methacrylate), 4-mm greenhouse glass, and 16-mm double-layered glass were used as the covering materials of the chamber. In order to understand the effect of the external wind directions, the windward and downwind insulation properties were evaluated. As a result of comparing the thermal insulation effect of each greenhouse cover material to single-layer glass, the thermal insulation effect of double-layer glass was 16.9% higher, while PMMA and PC were 62.5% and 131.2% higher respectively. On average the wind speed on the windward side was 53.1% higher than that on the lee-wind side, and the temperature difference between the inside and outside of the chamber at the wind ward side was found to be 52.0% larger than that on the lee ward side. During the experiment period, the overall heating operation time for PC was 39.2% lower compared to other insulation materials. Showing highest energy efficiency, and compared to PC, single-layer glass power consumption was 37.4% higher.

Abosrbed Dose Measurements and Phantom Image Ecaluation at Minimum CT Dose for Pediatric SPECT/CT Scan (소아 SPECT/CT 검사를 위한 최저조건에서의 피폭선량측정 및 팬텀의 영상평가)

  • Park, Chan Rok;Choi, Jin Wook;Cho, Seong Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.82-88
    • /
    • 2014
  • Purpose: The purpose of study was to evaluate radiation dose for pediatric patients by changing tube voltage (kVp) and tube current (mA) at minimum conditions. By evaluating radiation dose, we want to provide dose reduction for pediatric patients and maintain good quality of SPECT/CT images. Materials and Methods: Discovery NM/CT 670 Scanne was used as SPECT/CT. Tube voltages are 80 and 100 kvP. Tube currents are 10, 15, 20, 25 mA. Using PMMA (Polymethyl methacrylate) Phantom, radiation dose which were calculated at center and peripheral dose and SNRD (Signal to Noise Ratio Dose) were evaluated. Using the CT performance phantom, spatial resolution was evaluated as the MTF (Modulation Transfer Function) graph. Jaszczak phantom was used for SPECT image evaluation by CNR (Contrast to Noise to Ratio). Results: Radiation dose using the PMMA phantom was higher peripheral dose than center dose about 7%. SNRD were 7.8, 8.2, 8.3, 8.8, 8.8, 9.9, 9.8, 9.6 for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. We can distinguish 35, 45, 70, 71, 52, 58, 90, 110 linepair for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA at resolution with MTF. CNR of SPECT images using CT attenuation map were 57.8, 57.7, 57.1, 56.7, 56.6, 56.7, 56.7, 56.7% for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. Conclusion: In this study, radiation dose for pediatric patients showed decreased low dose condition. And SNRD value was similar in all condition. Resolution showed higher value at 100kVp than 80kVp. for CNR, there was no significant difference. we should take additional study to prove better quality and dose reduction.

  • PDF

Comparative study of volumetric change in water-stored and dry-stored complete denture base (공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구)

  • Kim, Jinseon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Purpose: Generally, patients are noticed to store denture in water when removed from the mouth. However, few studies have reported the advantage of volumetric change in underwater storage over dry storage. To be a reference in defining the proper denture storage method, this study aims to evaluate the volumetric change and dimensional deformation in case of underwater and dry storage. Materials and methods: Definitive casts were scanned by a model scanner, and denture bases were designed with computer-aided design (CAD) software. Twelve denture bases (upper 6, lower 6) were printed with 3D printer. Printed denture bases were invested and flasked with heat-curing method. 6 upper and 6 lower dentures were divided into group A and B, and each group contains 3 upper and 3 lower dentures. Group A was stored dry at room temperature, group B was stored underwater. Group B was scanned at every 24 hours for 28 days and scanned data was saved as stereolithography (SLA) file. These SLA files were analyzed to measure the difference in volumetric change of a month and Kruskal-Wallis test were used for statistical analysis. Best-fit algorithm was used to overlap and 3-dimensional color-coded map was used to observe the changing pattern of impression surface. Results: No significant difference was found in volumetric changes regardless of the storage methods. In dry-stored denture base, significant changes were found in the palate of upper jaw and posterior lingual border of lower jaw in direction away from the underlying tissue, maxillary tuberosity of upper jaw and retromolar pad area of lower jaw in direction towards the underlying tissue. Conclusion: Storing the denture underwater shows less volumetric change of impression surface than storing in the dry air.