• 제목/요약/키워드: Polymer insulator

검색결과 212건 처리시간 0.026초

카올린 오손물 누적량 및 누설전류 변화에 관한 연구 (A Study on Kaolin Contaminant Accumulation Contents and Leakage Current Variation)

  • 박재준;송일근;이재봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.145-146
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW.

  • PDF

피뢰기 절연행거의 기계적 강도 특성 (Mechanical Strength Properties of Hanger Insulator for Arrestor)

  • 박기호;조한구;한동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.589-592
    • /
    • 2001
  • Generally, hanger insulator for polymer arrestor have to be good insulation properties and mechanical strength and weatherability, But many remark and repairs have been to think about low cost and light weight. The Paper is used Polymer arrestor for post and performance analysis and mechanical strength insulator hanger according to development of simplest product. To enhance the efficiency of experimental modal analysis, we proposed the process which is the selection of the locations and the number of measurement points for pre-test.

  • PDF

플라즈마 중합법에 의한 게이트 절연박막의 제작 및 특성 (Fabrication and Characterization of Gate Insulator Thin Films prepared by Plasma Polymerization)

  • 손영도;황명환;임재성;신백균
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.48-53
    • /
    • 2011
  • Polymer thin films were prepared by capacitively coupled plasma polymerization process for application of gate insulator. The polymer thin films revealed to form polymer layers with original properties of the monomer. Among the plasma polymer thin films, the styrene polymer having large number of phenyl sites revealed higher dielectric constant of k=3.7 than that of conventional polymer. The plasma polymerized styrene thin film revealed no hysteresis characteristics and low leakage current density of $1{\times}10^{-8}[Acm^{-2}]$ at field strength of $1[MVcm^{-1}]$, which measured by I-V and C-V measurements using MIM and MIS devices.

고분자 절연물의 내오손 진단을 위한 누설전류 특성 해석 (The analysis of leakage current characteristics of polymer insulators for estimation under Pollution conditions)

  • 김인성;한세원;조한구;소진중;김형식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1452-1454
    • /
    • 1997
  • Properties of flashover in polymer insulators are very important under pollution environments. It is necessary to analyse flashover characteristics whether insulators are still safe or not. A lot of precious information can be got out of polluted polymer insulators through leakage current measurement. The behavior of partial arc discharge leads to flashover directly. It is possible to measure partial arc discharge as leakage current pulses analysis. The shape of histogram reflects degree of pollution, wetting and voltage stress level. It can be expressed by Weibull distribution function.

  • PDF

폴리머 애자의 End-fitting 설계 및 성능 평가기술 (End-fitting Design and Performance Evaluation of Polymer Insulator)

  • 조한구;이운용;한세원;한동희;지원영;여학규;강두원;천종욱;이형규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.25-29
    • /
    • 2004
  • Corona on polymer materials causes deterioration by the combined action of the discharge striking the surface and the action of certain chemical compounds that are formed by the discharges. In the design and manufacture of polymer insulators must be sufficiently large to avoid corona discharges, otherwise a shielding or corona ring (grading ring) needs to be installed on the insulator. To conduct this purpose, many researchers have investigated end-fitting of polymer insulator by voltage distribution simulation and electrical test. Grading rings are used to improve the performance of the insulator in multiple ways. They can reduce corona and associated audible noise and radio influence and television interference. The factors determining the uses of a grading ring are line voltage, geometry and dimensions of end fittings, geometry and dimensions of line hardware, and environmental conditions. In this paper, electrical property of polymer insulator with end-fitting design have been investigated by electrical field analysis, various end-fitting design, tracking wheel test, corona inception voltage and extinction voltage. Electrical field analysis is conducted by FEM program and various end-fitting is designed through this result. Designed end-fittings are manufactured and their performance is conducted by electrical performance test.

  • PDF

송전선로 폴리머애자 공사용 장비 개발 (Development of Working Platform for the Polymer Insulator String)

  • 민병욱;위화복;방항권;최한열;백수곤;박재웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.438-439
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea to insulate a transmission line from the tower, and a highly polymerized compound polymer insulator which has superior stain proof characteristics, has also been used widely. Currently, a worker rides on the suspension insulator string for installation on towers and conductors but in case of polymer insulators, this will pollute and scratch the housing result in durability reduction by deterioration and corona. This study developed a high strength aluminum compound metal lauder designed to work on polymer insulators without riding, and a clamp type connecting device and safety gear for easy installation on the tower and conductor. These polymer insulator work device can be used for 154kV and 345kV polymer insulators through a strength and load test to secure safety. This paper presents field usage.

  • PDF

배전용애자의 경년시험방법과 폴리머애자의 개발 동향 (The aging test method of insulator and development prospect of polymer insulator)

  • 송일근;김상준;김주용;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1791-1793
    • /
    • 1996
  • This paper describes Thermal-Mechanical performance and Ultimate Mechanical-Strength test for the purpose of aging analysis of suspension insulator. The temperature difference of insulator surface according to the aging of suspension insulator brought out about $2^{\circ}C$ to $7-8^{\circ}C$ difference comparing with the atmospheric temperature. Quality standard and Mechanical-Strength of used suspension insulator deteriorate more remarkably than that of new suspension insulator. It is required that Thermal-Mechanical performance test standard be revised in the future. And it is described about the development prospect of polymer insulators

  • PDF

154kV 송전용 폴리머 애자의 산불에 대한 누설전류 및 온도 특성 (A Characteristics of Leakage Current and Temperature on Forest Fire of EHV Polymer Insulator for 154KV T/L)

  • 최인혁;최장현;박준호;이동일;김태영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.517-518
    • /
    • 2006
  • In this paper, to understand the effect of forest fires on polymer insulators for transmission lines, it was observed the aging of the housing surface of the polymer insulators. And, this paper shows the way how to create the artificial field testing in order to simulate forest fire. As the results of, maximum leakage current peaks by influence of flame increased from 1[mA] to 1.4[mA], and SEM results show the inorganic component on the housing surface because the organic component matters disappeared. Therefore, the case of exposed by forest fire, polymer insulator can be used in the early stage, but an exchange needs active countermeasure to be stabilize power delivery.

  • PDF

가공송전선로 애자 적용실태와 향후 전망 (Insulator application and prospect)

  • 김우겸;민병욱;김태영;위화복;최진성;이북창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.327_328
    • /
    • 2009
  • The insulator being used for transmission line is to mount the charged conductor on the tower or other supports. The insulators are classified according to its material: porcelain, glass and polymer. Polymer insulators are also called as composite insulator or non ceramic insulator (NCI). Insulators are a major element of a power transmission system. Since a faulty insulator can lead to a wide spreading blackout, it must have sufficient mechanical and electrical strength. It must be durable, have high electrical insulation and be able to withstand a leakage current. It must also be able to withstand the toughest weather conditions. In Korea, porcelain insulators have been used widely. However, to make compact equipment and keep up with global trends, we have enhanced domestic production of polymer insulator and are encouraging its applications. Accordingly, this thesis will look at types of insulators, use and trends, and prospects of insulators application in the field.

  • PDF

금속-고분자 계면에서의 전하의 거동 (Charge Carrier Behaviour of Metal-Polymer Interface)

  • 윤주호;최용성;안성수;문종대;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.373-374
    • /
    • 2008
  • Insulating polymers and their composites have been widely used in various electric apparatus or cables. Recently, the effects of interfaces (metal/insulator or insulator/insulator interfaces) on electrical insulation have attracted much attention. However, interfacial phenomena in actual insulation systems and their physical backgrounds are not well understood yet. In this paper, the behaviour of charge carriers near the metal/polymer interface and its effects on conduction and breakdown phenomena are discussed. The metal/polymer interface strongly affects carrier injection, space charge formation and breakdown phenomena. Based on their experimental results, the physical backgrounds of the interfacial phenomena are explained.

  • PDF