• 제목/요약/키워드: Polymer heart valve

검색결과 23건 처리시간 0.023초

단엽식 고분자판막의 혈역학적 성능평가 (Hemodynamic Evaluation of Monoleaflet Polymer Valve)

  • 김상현;장병철
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권1호
    • /
    • pp.61-66
    • /
    • 1995
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane. To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medicals prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volllme and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF

의공산업의 현황과 전망

  • 고영환
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권2호
    • /
    • pp.91-93
    • /
    • 1989
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF

지지대 형상에 따른 단엽식 고분자 판막의 비선형 해석 (Nonlinear Analysis of the Monoleaflet Polymer Valve according to Shape of Supporting Members)

  • 한근조;안성찬;심재준;김성윤
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.120-124
    • /
    • 2003
  • Monoleaflet polymer artificial heart valve was known to show remarkable improvement in antithrombosis and pressure drop compared with other type of artificial valve. In this investigation of monoleaflet heart valve the vertical and horizontal deflection pattern of polymer heart valve with three types of supporting members, straight member and two curved members were analysed using the large deformation nonlinear finite element method.

지지대 형상에 따른 단엽식 고분자 판막의 비선형 해석 (Nonlinear Analysis of the Monoleaflet Polymer Valve According to Shape of Supporting Members)

  • 한근조;안성찬;심재준;김성윤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.748-751
    • /
    • 2001
  • Monoleaflet polymer artificial heart valve was known to show remarkable improvement in antithrombosis and pressure drop compared with other type of artificial valve. In this investigation monoleaflet the vertical and horizontal deflection pattern of polymer heart valve with three types of supporting members straight member, and two curved members was analysed using the large deformation nonlinear finite element method.

  • PDF

부유식 폴리머 인공심장 밸브의 축대칭 혈류 해석 (Axisymmetric analysis of blood flow for a floating type polymer artificial heart valve)

  • 성현찬;정기석;김경훈;고형종;박찬영;민병구;심은보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.703-704
    • /
    • 2002
  • The two major problems related to the blood flow in a floating type polymer valve are thrombus formation and hemolysis. It is well known that the shear stress in the fluid and flow separation around the valve are blamed for such disastrous phenomena. In this viewpoint, through study of the flow field around the valve is imperative to improve design of the valve. The aim of this study is to investigate the fluid flow around a floating type polymer valve. The numerical method employed in this study is the finite element software called ADINA. Incompressible viscous flow is assumed for blood using the assumption of Newtonian fluid. In this study, two prominent features of the axisymmetric flow around the floating type polymer valve are observed: jet-like flows observed near the gap between the conduit and the valve, and recirculating flow downstream of the valve. We also provided a detailed description of shear stress field according to the variation of flow conditions. The shear stress in fluid has its maximum value near the gap between the valve and the conduit.

  • PDF

진공성형을 이용한 삼엽식 고분자 심장판막의 제작과 혈류역학적 성능평가 (Assessment of Hemodynamic Properties of Trileaflet Polymer Heart Valve Manufactured By Vacuum Forming Process)

  • 김경현;황창모;정기석;안치범;김범수;이정주;남경원;선경
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.418-426
    • /
    • 2006
  • In the artificial heart application, productivity and hemodynamic properties of artificial heart valves are crucial in successiful application to long term in vivo trials. This paper is about manufacture and assessment of trileaflet polymer heart valves using vacuum forming process(VFP). The VFP has many advantages such as reduced fabrication time, reproducibility due to relatively easy and simple process for manufacturing. Prior to VFP of trileaflet polymer heart valves, polyurethane(Pellethane 2363 80AE, Dow Chemical) sheet was prepared by extrusion. The sheets were heated and formed to mold shape by vacuum pressure. The vacuum formed trileaflet polymer heart valves fabrication is composed of two step method, first, leaflet forming and second, conduit forming. This two-step forming process made the leaflet-conduit bonding stable with any organic solvents. Hydrodynamic properties and hemocompatibility of the vacuum formed trileaflet polymer heart valves was compared with sorin bicarbon bileaflet heart valve. The percent effective orifice area of vacuum formed trileaflet polymer heart valves was inferior to bileaflet heart valve, but the increase of plasma free hemoglobin level which reflect blood damage was superior in vacuum formed trileaflet polymer heart valves Vacuum formed trileaflet polymer heart valves has high productivity, and superior hemodynamic property than bileaflet heart valves. Low manufacturing cost and blood compatible trileaflet polymer heart valves shows the advantages of vacuum forming process, and these results give feasibility in in vivo animal trials in near future, and the clinical artificial heart development program.

인공심장용 폴리머 밸브의 역류 특성 분석 (A study on the performance of the polymer valve in Total Artificial Heart)

  • 이정주;최종훈;이정훈;이서우;엄경식;안재목;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.241-242
    • /
    • 1998
  • For the aritificial heart valve, two types of valves-polymer and mechanical valve- are generally used. The polymer valve is used as a new low-cost artificial valve. Among the several properties of the artificial valve, the low-regurgitation property is important because it can provide better cardiac output characteristic. So in this study we analyzed and compared the regurgitation property of the mechanical valve which is generally used nowdays and the polymer valve which was made in our group. As results, the polymer valve showed the better regurgitation property compared to the mechanical valve approximately by 3 times, and increased the cardiac output by 10%.

  • PDF

응력과 변형을 최소화하기 위한 단엽식 고분자 판막의 지지대 위치에 관한 연구 (A Study on the Location of Supporting Members in Monoleaflet Polymer Valve to Minimize Stress and Deformation)

  • 이성욱;심재준;한동섭;한근조;김태형
    • 한국정밀공학회지
    • /
    • 제22권2호
    • /
    • pp.156-163
    • /
    • 2005
  • A monoleaflet polymer artificial heart valve showed the remarkable improvement in pressure drop compared with other types of artificial valve. So, in this study we designed a monoleaflet polymer artificial valve with two supporting members to minimize the deformation and bending stress of the valve with respect to the variation of the gap between two supporting members using nonlinear contact analysis. The marginal valve thickness was also predicted in accordance with the relationship between the thickness and horizontal displacement in order to prevent the dislocation of the valve tip from the frame wall.

삼엽식 인공판막의 수력학적 성능평가에 관한 연구 (A Study on the Evaluation of Hydrodynamic Performance of Trileaflet Prosthetic Heart Valves)

  • 김혁필;이계한
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.147-156
    • /
    • 1997
  • Various prosthetic heart valves have been developed and used clinically, but they have problems, such as thrombogenecity, hemoltsis, high cost and low durability. New types of trileaflet polymer heart valves have been developed in order to use them as inlet and outlet valves in a ventricular assist device. The aim of this study is to determine the hydrodynamic effectiveness of the newly designed trileaflet polymer valves and their feasibility for temporary use in the blood pumps. Trileaflet polymer valves are made of polyurethane, because of its good blood compatibility, high tonsil strength and good resistance to fatigue. An in vitro experimental investigation was perf'ormed in order to ev91ua1e hydrodynamic performance of the trileaflet polymer valves having different design and fabrication tech- niques. The St. Jude Medical valve (SJMV) and floating-type monoleaflet polymer valve (MLPV) were also tested The pressure drop across the valve, leakage volume, and the flow patterns mere investigated for valves. The result of comparative tests showed that the trileaflet polymer valves had a better hydrodynamic performance than the others. TPV which has two stable membrane shape showed the lowest back flow. The pressure hops of TPVs were lower than that of MLPV, but slightly higher than SJMV. The hydrodynamic performance of valves under the pulastile flow showed the similar results as steady flow. The velocity profiles and turbulent intensities were measured at the distal sites of valves using a hot-film anemometer. Central flow was maintained in trileaflet polymer valves, and the maximum turbulent intensities were lower in TPVs comparing to MLPV.

  • PDF

인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향 (The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves)

  • 이계한;서종천
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.297-303
    • /
    • 1998
  • 판막 후부의 공동부는 판막의 닫힘 거동과 판막 주위의 혈류 유동장을 변화시켜 인공 판막의 수력학적 성능에 영향을 미칠 수 있다. 계식 이엽 판막(SJMV), 폴리머 단엽 판막(MLPV), 폴리머 삼엽 판막(FTPV)을 판막 후부에 공동부가 있는 시험부와 공동부가 없는 직관형 시험부에 설치하여 모의 순환 장치에서 판막의 수력학적 성능을 평가하였다. 판막의 누수량은 공동부가 있는 시험부에서 약간 작았고, 수축기 평균 압력강하는 크게 나타났으나 통계적으로는 큰 차이가 없었다. 따라서 판막 후부의 공동부는 판막의 수력학적 성능에 큰 영향을 나타내지 않았다. 유량 파형의 해석 결과 판막 후부 공동부는 MLPV에서는 판막의 닫힘에 큰 영향을 주지 않았으나, SJMV에서는 판막의 닫힘이 일찍 시작하게 하였고 이 영향은 FTPV에서 더욱 크게 나타났다. FTPV는 공동부가 있는 시험부에서 역류 최대 유량이 감소하였으므로 판막 후두에 공동부는 판막의 급격한 닫힘에 의한 역류 제트의 발생을 감소시키리라 기대된다.

  • PDF