• 제목/요약/키워드: Polymer cantilever

검색결과 31건 처리시간 0.03초

심근세포 성숙도 및 수축력 향상을 위한 AgNW 기반의 기능성 폴리머 캔틸레버 (AgNW-based functional polymer cantilever to improve maturity and contractility of cardiomyocytes)

  • 정민영;심유리;윤하영;김동수;이동원
    • 센서학회지
    • /
    • 제30권3호
    • /
    • pp.185-189
    • /
    • 2021
  • Herein, we propose a functional polymer cantilever to enhance maturation and contractile force of cardiomyocytes. The proposed cantilever consists of a surface-patterned polymer substrate and silver nanowires (AgNWs). The AgNWs are transferred to the PDMS substrate using conventional molding techniques. This thin metallic surface significantly improves the adhesion of cardiomyocyte on the surface-patterned PDMS with the hydrophobic characteristics. In addition, the use of AgNWs improves the visibility of the conducting PDMS substrate for the observation of cardiomyocyte through an inverted microscope. The AgNWs also assist in synchronizing each cardiomyocyte to maximize its contractile force.

외팔보형 IPMC 구동기의 이론적 모델링과 구동특성 (Theoretical Modeling and Dynamic Characteristics of a Cantilever IPMC Actuator)

  • 한대웅;이승엽
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1521-1526
    • /
    • 2008
  • IPMC(Ionic Polymer-Metal Comosite) exhibits large deformation, having great attention in many application fields. It generates bending moment by ion exchange polymer film. It can be quickly bended by the applied voltage across the plated electrode of the polymer film. In the present paper, we derive the theoretical modeling and dynamic analysis of bending motions of IPMC actuators using the Euler-Bernoulli beam theory. The theoretical model of a cantilever IPMC actuator estimates the moment produced by the applied voltage. The dynamic characteristics, including natural frequencies and frequency response, are calculated by the theoretical model, and they are compared with the experimental results and finite element analysis. It is shown that the mathematical modeling allows precise estimation to the voltage-driven motion of the cantilever IPMC in air.

  • PDF

Shaping of piezoelectric polyvinylidene fluoride polymer film for tip position sensing of a cantilever beam

  • 이영섭
    • 센서학회지
    • /
    • 제14권4호
    • /
    • pp.225-230
    • /
    • 2005
  • This paper describes a novel tip position sensor made of a triangularly shaped piezoelectric PVDF (polyvinylidene fluoride) film for a cantilever beam. Due to the boundary condition of the cantilever beam and the spatial sensitivity function of the sensor, the charge output of the sensor is proportional to the tip position of the beam. Experimental results with the PVDF sensor were compared with those using two commercially available position sensors: an inductive sensor and an accelerometer. The resonance frequencies of the test beam, measured using the PVDF sensor, matched well with those measured with the two commercial sensors and the PVDF sensor also showed good coherence over wide frequency range, whereas the inductive sensor became poor above a certain frequency.

생체 조직의 국소 강도 측정을 위한 마이크로 콘 팁을 가진 압전 캔틸레버 제작 (Fabrication of Piezoelectric Cantilever with Microcone Tip for Sensing Local Stiffness of Biological Tissue)

  • 노희창;양다솜;류원형
    • 대한기계학회논문집B
    • /
    • 제41권11호
    • /
    • pp.743-748
    • /
    • 2017
  • 체외 및 체내 삽입형 이미징 기술 등에 의해서는 판별이 어려운 질환의 조기 진단을 위해 인체 내 삽입이 가능하며 체내 국소부위의 정밀 측정이 가능한 새로운 진단기술이 필요하다. 동맥경화로 발전할 수 있는 죽상경화반의 경우 이미징 기술로는 판별이 어려우나 건강한 조직 대비 미세한 기계적 물성치의 차이를 가질 것으로 예상되어 정밀한 국소 조직의 기계적 강도 측정을 통한 조기 진단이 가능할 것으로 기대된다. 본 연구에서는 궁극적으로 체내 삽입이 가능하며 국소 조직의 강도 측정이 가능한 압전 재료 기반 캔틸레버 센서를 제작하고자 하였다. 압전 기능을 갖는 캔틸레버 제작을 위해 $BaTiO_3$ 나노입자 기반의 압전 고분자 복합재 최적화 연구 및 열 인장 공정으로 캔틸레버 끝 단에 마이크로 콘 구조의 팁을 제작하였다. 이 압전 캔틸레버 센서를 이용하여 기계적 물성치가 다른 생체 조직의 강도 측정을 통해 센서로서의 기능을 확인하였다.

약물처리된 심장세포의 세포 수축력 측정을 위한 병렬 폴리머 캔틸레버 제작 (Fabrication of a Parallel Polymer Cantilever to Measure the Contractile Force of Drug-treated Cardiac Cells)

  • 김동수;이동원
    • 센서학회지
    • /
    • 제29권2호
    • /
    • pp.100-104
    • /
    • 2020
  • Thus far, several in vivo biosensing platforms have been proposed to measure the mechanical contractility of cultured cardiomyocytes. However, the low sensitivity and screening rate of the developed sensors severely limit their practical applications. In addition, intensive research and development in cardiovascular disease demand a high-throughput drug-screening platform based on biomimetic engineering. To overcome the drawbacks of the current state-of-the-art methods, we propose a high-throughput drug-screening platform based on 16 functional high-sensitivity well plates. The proposed system simulates the physiological accuracy of the heart function in an in vitro environment. We fabricated 64 cantilevers using highly flexible and optically transparent silicone rubber and placed in 16 independent wells. Nanogrooves were imprinted on the surface of the cantilever to promote cell alignment and maturation. The adverse effects of the cardiovascular drugs on the cultured cardiomyocytes were systematically investigated. The 64 cantilevers demonstrated a highly reliable and reproducible mechanical contractility of the drug-treated cardiomyocytes. Real-time high-throughput screening and simultaneous evaluation of the cardiomyocyte mechanical contractility under multiple drugs verified that the proposed system could be used as an efficient drugtoxicity test platform.

Thermopiezoelectric Cantilever for Probe-Based Data Storage System

  • Jang, Seong-Soo;Jin, Won-Hyeog;Kim, Young-Sik;Cho, Il-Joo;Lee, Dae-Sung;Nam, Hyo-Jin;Bu, Jong. U.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권4호
    • /
    • pp.293-298
    • /
    • 2006
  • Thermopiezoelectric method, using poly silicon heater and a piezoelectric sensor, was proposed for writing and reading in a probe based data storage system. Resistively heated tip writes data bits while scanning over a polymer media and piezoelectric sensor reads data bits from the self-generated charges induced by the deflection of the cantilever. 34${\times}$34 array of thermopiezoelectric nitride cantilevers were fabricated by a single step wafer level transfer method. We analyzed the noise level of the charge amplifier and measured the noise signal. With the sensor and the charge amplifier 20mn of deflection could be detected at a frequency of 10KHz. Reading signal was obtained from the cantilever array and the sensitivity was calculated.

Nanostructure Fabrication using Dip-pen Nanolithography

  • Lee, Seung-Woo;Mirkin Chad A.
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.285-285
    • /
    • 2006
  • The ionic layer-by-layer (LBL) assembled films can be formed by sequentially dipping of substrates to oppositely charged polyions solution in the multilayer, called polyelectrolytes multilayer (PEM) films. Easy way of these assemblies of charged polymers offer the ability to adjust important parameters such as controllability of thickness in the nanometer-scale level and functionality of most top layer of PEM films. Nevertheless, we do not know of any trials to fabricate PEM organic films into nanometer size. Herein, we show the integration of the LBL technique with DPN in fabricating nanometer size patterns of multilayered polyelectrolyte structures. Through the use of single and multiple cantilever AFM probes, we demonstrate the parallel writing capabilities of DPN.

  • PDF

인장하중하에서의 고분자/거친금속 계면의 파손에 대한 비교연구 I: 실험결과 (Comparative Study on the Failure of Polymer/Roughened Metal Interfaces under Mode-I Loading I: Experimental Result)

  • 이호영;김성룡
    • 한국재료학회지
    • /
    • 제15권1호
    • /
    • pp.1-5
    • /
    • 2005
  • Copper-based leadframe sheets were immersed in two kinds of hot alkaline solutions to form brown-oxide or black-oxide layer on the surface. The oxide-coated leadframe sheets were molded with epoxy molding compound (EMC). After post mold curing, the oxide-coated EMC-leadframe joints were machined to form sandwiched double-cantilever beam (SDCB) specimens. The SDCB specimens were used to measure the fracture toughness of the EMC/leadframe interfaces under quasi-Mode I loading conditions. Fracture surfaces were analyzed by various equipment to investigate failure path. The present paper deals with the failure path, and the cause of the failure path formation with an adhesion model will be treated in the succeeding paper.