• Title/Summary/Keyword: Poly (vinyl alcohol)

Search Result 470, Processing Time 0.024 seconds

Preparation and Characterization of Pioglitazone Loaded PLGA Nanospheres for the Treatment of Type 2 Diabetes (제2형 당뇨병 치료제인 Pioglitazone을 봉입하기 위한 PLGA 나노입자 제조 및 분석)

  • Woo, Hyun-Ju;Kim, Jin-Soo;Kim, Jun-Gi;Nurunnabi, Md.;Huh, Kang-Moo;Cho, Kwang-Jae;Lee, Yong-Kyu
    • Polymer(Korea)
    • /
    • v.34 no.6
    • /
    • pp.527-533
    • /
    • 2010
  • The pioglitazone loaded poly(lactide-co-glycolide)(PLGA) nanospheres were prepared by emulsion-evaporation method and optimized for particle size and entrapment efficiency. The optimized particles were 125~170 nm in size with narrow size distribution and showed above 85% entrapment efficiency at 30% of pioglitazone loading when prepared with 3% w/v of poly(vinyl alcohol) (PVA) as a surfactant. These particulate carriers exhibited a controlled in vitro release of pioglitazone for 40 days at a nearly constant rate. The pioglitazone loaded PLGA nanospheres were not only effective to reduce the blood sugar level of diabetic rats but also non-toxic for the animal body, in particular for sensitive organs like kidney, liver, heart, lung and spleen. These results indicate that PLGA nanospheres have a great potential for oral delivery of pioglitazone.

Preparation and Release Characterization of Biodegradable Poly($\varepsilon$-caprolactone) Microcapsules Containing Tocopherol (토코페롤을 함유하는 생분해성 폴리($\varepsilon$-카프로락톤) 마이크로캡슐의 제조 및 방출 특성)

  • 박수진;김기석;민병각;홍성권
    • Polymer(Korea)
    • /
    • v.28 no.2
    • /
    • pp.103-110
    • /
    • 2004
  • The biodegradable poly($\varepsilon$-caprolactone) (PCL) microcapsules containing tocopherol were prepared by oil-in-water emulsion solvent evaporation method. The features of the microcapsules were investigated in the manufacturing conditions and degradation behaviors. The form and structural feature of the microcapsules were measured by scanning electron microscope and X-ray diffraction, respectively. The surface free energy of the microcapsules was executed using contact angle measurement. As a result, the microcapsules were more stable and spherical with poly(vinyl alcohol) given in a surfactant. The surface free energy and crystallinity of microcapsules were decreased with increasing the core concentration, and degradation of PCL was occurred after 21 days. The release behaviors were examined by Uv/vis. spectrophotometer. It was found that the release rate of the microcapsules was increased with increasing the stirring rate, due to the increased interface between microcapsules and release media.

Improved Coating of PEDOT : PSS onto CVD Graphene by the Addition of PVA (PVA의 첨가에 의한 CVD 그래핀상 PEDOT : PSS의 코팅성 향상)

  • Park, Min Ui;Shin, Chaeyeon;Kim, Hyeji;Kim, Seung Yeon;Choi, Young Ju;Chung, Dae-won
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.734-739
    • /
    • 2018
  • We successfully coated poly(3,4-ethylenedioxythiophene) : poly(styrene sulfonate) (PEDOT : PSS) on CVD graphene by adding poly(vinyl alcohol) (PVA) to PEDOT : PSS. Extensive studies on the wettability of coating solutions and electrical properties of formed films led us to conclude that PVA with 89% of the degree of saponification and the molecular weight of less than $100,000gmol^{-1}$ produced optimum results. Furthermore, the optimum content of PVA was found to be 5% of PEDOT : PSS by the solid weight. The film coated by PEDOT : PSS with PVA on CVD graphene displayed a conspicuous improvement in the surface roughness, adhesive property, bending durability and stability in resistance at $160^{\circ}C$, compared to those of using CVD graphene films.

Fabrication of CO2 Sensor Membrane by Photolithographic Method (사진식각법을 이용한 CO2 센서 감지막의 제조)

  • Park, Lee Soon;Kim, Sang Tae;Koh, Kwang-Nak
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.6-12
    • /
    • 1998
  • A FET(Field Effect Transistor) type dissolved $CO_2$ sensor based on Severinghaus type $CO_2$ sensor was fabricated by the photolithographic process. The sensor consists of Ag/AgCl reference electrode and membranes (hydrogel membrane and $CO_2$ gas permeable membrane) on the pH-ISFET base chip. Ag/AgCl reference electrode was fabricated as follows. Ag layer was thermally evaporated and then its upper surface was chemically chloridized into the AgCl. The hydrogel used as an internal electrolyte solution was fabricated by a photolithographic method using 2-hydroxyethyl methacrylate(HEMA) and acrylamide. $CO_2$ permeable membrane on the top of the hydrogel layer was formed by photolithographic process with UV-oligomer. The FET type $pCO_2$ sensor fabricated by photolithographic method showed good linearity within the concentration range of $10^{-3}{\sim}10^0mole/{\ell}$ of dissolved $CO_2$ in aqueous solution with high sensitivity.

  • PDF

Preparation of Silver Nanoparticles Using AgNO3 Precursor as Carrier for Olefin/Paraffin Separation and the Effect Analysis of NO3- (올레핀/파라핀 분리용 운반체로서 AgNO3 전구체를 활용한 은 나노입자 제조 및 NO3-의 효과 분석)

  • kim, Minsu;Kang, Sang Wook
    • Membrane Journal
    • /
    • v.28 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • In previous studies, a poly(ethylene oxide)(PEO)/Ag nanoparicles (AgNPs)(precursor $AgBF_4$)/p-benzoquinone (p-BQ) composite membrane was prepared for olefin/paraffin separation and the performance of this composite membrane was maintained at a selectivity of 10 and a permeability of 15 GPU. However, since the price of $AgBF_4$ precursor is high, this study used $AgNO_3$ as a precursor of Ag nanoparticles which is competitive in terms of price. As a result, it was observed that the separation performance was not obtained because the existing $NO_3{^-}$ could surround AgNPs. In this study, we fabricated PEO, poly(vinyl alcohol)(PVA), and polyether block amide-1657 (PEBAX-1657) polymer composite membrane using electron acceptor 7,7,8,8-tetracyanoquinodimethane (TCNQ) for separation performance even when $AgNO_3$ was used as a precursor of Ag nanoparticles. As a result, it was analyzed that the performance was not observed regardless of the influence of the polymer and the electron acceptor, indicating that the anion of the precursor plays a crucial role in the separation performance.

Evaluation of the Stability of Biodegradable Nanoparticle with Time via Particle Size Measurement (입자 크기 측정을 통한 생분해성 나노입자의 시간에 따른 분산 안정성 평가)

  • Cho, Kuk-Young;Yim, Jin-Heong;Park, Jung-Ki;Lee, Ki-Seok
    • Polymer(Korea)
    • /
    • v.32 no.3
    • /
    • pp.246-250
    • /
    • 2008
  • Colloidal stability of the biodegradable nanoparticle was characterized by measuring the variation of particle size with time using photon correlation spectroscopy. Three kinds of polymers, namely, poly(D,L-lactide-co-glycolide)(PLGA), PLGA/poly(L-lactide) blends, and PLGA/poly(L-lactide)-g-poly(ethylene glycol) blends were used as matrix material for nanoparticle preparation. Nanoparticles were prepared with or without using poly(vinyl alcohol)(PVA) as suspension stabilizer to evaluate the condition of preparation. Nanoparticles from the blend of amphiphilic graft copolymer with short poly(ethylene glycol) chain and PLGA maintained suspension for 1 day when protein stock solution was introduced. This is somewhat improvement in colloidal stability against protein adsorption compared with that of nanoparticles without PEG moiety. Suspension stabilizer, PVA, had a significant effect on the colloidal stability against freezing and protein adsorption which led to coagulation of nanoparticles. It is important to consider effect of suspension stabilizer as well as materials used to prepare nanoparticle on the colloidal stability.

Characteristics Analysis of Nano-composites Films Using Extruder (압출성형기를 이용한 나노복합재 필름의 특성 분석)

  • Kwon, Il-Jun;Park, Sung-Min;Yoo, Sung-Hun;Yeum, Jeong-Hyun
    • Textile Coloration and Finishing
    • /
    • v.28 no.2
    • /
    • pp.101-108
    • /
    • 2016
  • Polypropylene(PP)/multiwalled carbon nanotubes(MWCNT) nanocomposites films and PP/poly(vinyl alcohol)/CNT nanocomposites films were prepared through melt mixing method by the extruder. The PP/CNT nanocomposites films, which contain CNT of a variable content, were prepared for the first time and research on a appropriate content of the CNT on the PP/CNT nanocomposites films was conducted. The effects of take-up speed of the extruder on the mechanical and chemical properties of the PP/CNT and PP/PVA/CNT nanocomposites film were studied. Field emission scanning electron microscope(FE-SEM) was used to examine the surface morphology and the DSC measurement and tensile test were conducted. It was found that the properties decreased when take-up speed was increased.

Electro-responsive Transdermal Drug Release of MWCNT/PVA Nanocomposite Hydrogels

  • Kim, Yeon-Yi;Yun, Ju-Mi;Lee, Young-Seak;Kim, Hyung-Il
    • Carbon letters
    • /
    • v.11 no.3
    • /
    • pp.211-215
    • /
    • 2010
  • Multi-walled carbon nanotube (MWCNT)/poly(vinyl alcohol) (PVA) nanocomposite hydrogels were prepared by freezingthawing method for the electro-responsive transdermal drug delivery. MWCNTs were used as the functional ingredient to improve both mechanical and electrical properties of MWCNT/PVA nanocomposite hydrogels. The morphology of nanocomposites revealed the uniform distribution of MWCNTs and the good interfacial contact. The compression moduli of hydrogel matrices increased greatly from 40 to 1500 kPa by forming MWCNT/PVA nanocomposites. The swelling ratio of MWCNT/PVA nanocomposites decreased as the content of MWCNTs increased under no electric voltage applied. However, the swelling ratio of MWCNT/PVA nanocomposites increased as the content of MWCNTs increased under electric voltage applied and the applied electric voltage increased. The drug was released in the electro-responsive manner through the skin due to the electro-sensitive swelling characteristics of MWCNT/PVA nanocomposite hydrogels.

The Fabrication of PVA Polymer Coated on the Surface of B4C Nanocomposite by High Energy Ball Mill (고에너지볼밀을 이용한 PVA 고분자가 표면 코팅된 B4C 나노복합재 제조)

  • Uhm, Young-Rang;Kim, Jae-Woo;Jung, Jin-Woo;Rhee, Chang-Kyu
    • Journal of Powder Materials
    • /
    • v.16 no.2
    • /
    • pp.110-114
    • /
    • 2009
  • Mechanical coating process was applied to form 89 %-hydrolyzed poly vinyl alcohol (PVA) onto boron carbide ($B_4C$) nanopowder using one step high energy ball mill method. The polymer layer coated on the surface of B4C was changed to glass-like phase. The average particle size of core/shell structured $B_4C$/PVA was about 50 nm. The core/shell structured $B_4C$/PVA was formed by dry milling. However, the hydrolyzed PVA of $98{\sim}99%$ with high glass transition temperature ($T_g$) was rarely coated on the powder. The $T_g$ of polymer materials was one of keys for guest polymer coating on to the host powder by solvent free milling.

A Characterization of the Permeation and Separation of Electrolyte Solutions Through Charged Membranes in the Reverse Osmosis Process (이온성 막을 이용한 역삼투압 막 분리 공정에서 전해질 수용액의 투과분리 특성연구)

  • 염충균;최정환;이정민;서동수
    • Membrane Journal
    • /
    • v.11 no.1
    • /
    • pp.22-28
    • /
    • 2001
  • Various charged homogeneous membranes were fabricated by blending of ionic polymer with a non-ionic polymer with different ratios. In this study. sodium alginate, chitosan and poly(vinyl alcohol) were employed as anionic. cationic and non-ionic polymers, respectively. The permcation and separation behaviors of aquCOll::; salt solutions have been investigated through the charged membranes. As the content of ionic polymer increases in the membrane, the hydrophilicity of the membrane increases and pure water flux as well as solution flux increases correspondingly, indicating that the permeation performance through the membrane is cletemunecl mainly by its hydrophilicity-, Electrostatic interaction between the charged membrane and ionic solute molecules, that is. Donnan exclusion was observed to be attributed to salt rejection to a great deal of extent, and molecular sieve mechanism was effective [or the separation of the salt solution under a similar electrostatic circumstance of solutes.

  • PDF