• Title/Summary/Keyword: Pole mount

Search Result 12, Processing Time 0.036 seconds

Study on design of the magnetic pole used in the dashpot type MR fluid mount (대시포트형 MR유체 마운트의 자극설계에 관한 연구)

  • park, Woo-Cheul;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.482-487
    • /
    • 2009
  • This research proposed a dashpot type mount design using MR fluids, and derived governing equation of the proposed design considering the design parameters of the mount and the Bingham characteristics of MR fluids, which affect the damping forces of the dashpot MR fluid mount. In odor to observe the change of magnetic properties which occurs from the solenoid, the effective length of the magnetic pole and the structure of core are selected as design parameters. The magnetic field quality is calculated in compliance with an equivalent magnetic circuit method. When the effective length of pole increases, the magnetic resistance of the pole of the MR mount decreased, and the magnetic flux density is increased. The result which uses a commercial business software and the result in compliance with equivalent magnetic circuit method shows the tendency which is similar.

Design and Manufacture Technology of Polymer Bushing for Pole Mount Transformer (배전급 주상 변압기용 폴리머 부싱 설계 및 제조기술)

  • Cho, Han-Goo;Lee, Un-Yang;Cheon, Jong-Uk;Park, Young-Doo;Kang, Young-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.145-149
    • /
    • 2005
  • Recently, polymer insulator and bushing that are used for high voltage application have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. The pole mount transformer installed in distribution system is acting direct role in supply of electric power and the electric power device should drive safely for long tenn. In this paper, the polymer bushing of pole transformer is designed adaptively to current assembly method, designed bushing is manufactured on basis of that result. The electric field of designed transformer is investigated by FEM program.

  • PDF

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

An Experimental Study on the Design Parameters of the Dashpot type MR fluid mount (대시포트형 MR유체 마운트의 설계 인자에 대한 실험적 고찰)

  • Park, Woo-Cheul;Kim, Il-Gyoum;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3567-3573
    • /
    • 2009
  • This research proposed a dashpot type mount design using MR fluids, and investigated experimentally the influence of the design parameters of the dashpot MR fluid mount, which affect the damping forces of the dashpot MR fluid mount. In order to observe the influence, the dashpot MR fluid mount which have the different effective length and the core structure is manufactured. The variations of the resistance forces according to different effective lengths of the magnetic pole of MR fluid mount, along which magnetic field is defined, was investigated. It was founded that the resistance forces from the MR mount decreased with increased input frequencies, while increased with increased applied electric current intensities. Nevertheless, there is no appreciable change in the resistance forces with respect to the effective length variations of the magnetic pole of MR fluid mount.

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드 변압기의 덕트에 따른 열해석 특성 연구)

  • 조한구;이운용;박영두
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.348-352
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and ow loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding (일체형 주상용 몰드 변압기의 온도분포 및 특성 비교)

  • Cho, Han-Goo;Lee, Un-Yong;Kang, Tack-Sou;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

The Energized Aging Property of Pole Mount Mold transformer by Back-to-back Method (반환부하법에 의한 옥외 주상용 몰드변압기의 과전열화 특정)

  • Hwang, Bo-Guk;Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.484-487
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. In this paper, the proto type mold transformer of 50kVA class is investigated by routine, type, special test. The outdoor energized aging test is investigated by back-to-back method to verify the long time performance of pole mold transformer. The aging process of transformer is analyzed by various diagnosis method such as DC voltage-current test, $tan{\delta}$, Meggar measurement, winding temperature and etc.

  • PDF

Performance Analysis of 1.8GHz CDMA 1x Reverse Link including Tower Mount LNA (Tower Mount LNA 장착에 따른 CDMA PCS 기지국의 역방향 성능 분석)

  • Park Sang-Hyeon;Choe Yeong-Wan;Yun Yeong-Sang;Jang Jae-Seon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.143-148
    • /
    • 2003
  • In this paper, we focused on the performance of reverse link in 1.8GHz CDMA 1x system including the Tower-Mount LNA in an urban environment. In order to study the benefit of TMLNA, Hata model is used and the effects of multiple cells are considered. Cell coverage extension ratio is proportional to the increased gain of TMLNA in CDMA cell site. However the cell coverage is not extended even if the noise figure of TMLNA is reduced in an urban area. When typical RSSI is between -70dBm and -80dBm, the increased gain and the reduced NF of TMLNA are not impact to the pole capacity of cell site. Namely, the benefit of TMLNA in an urban area is not the problem of capacity but the proble of sensitivity. The results are also shown that reverse link $E_b/N_o$ is improved by minimum 5dB and BER is lower than $10^{-6}$.

  • PDF

Study on design parameters of the magnetic pole used in the dashpot type MR fluid mount (대시포트형 MR유체 마운트의 자극 설계 인자에 관한 연구)

  • Park, Woo-Cheul;Lee, Hyun-Chang;Choi, Sin-Hyeong;Kong, Jun-Sik;Kim, Il-Gyoum
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.433-435
    • /
    • 2008
  • 본 연구에서는 MR 유체를 특징으로 하는 대시포트형 마운트를 제안하고, 자극 형상의 변화가 MR유체 마운트의 감쇠력에 미치는 영향에 대하여 고찰하였다. 제안된 MR유체 마운트의 코어부에 발생하는 자기 특성에 대하여 살펴보기 위하여 자극(Magnetic pole)의 유효길이와 코어 중심부의 구조를 달리하여 대시포트를 제작하였다. 등가자기회로를 이용한 대략적인 계산방법에 의한 결과 자극의 유효길이가 증가할수록 자기저항은 감소하는 경향을 나타내지만, 그 밖의 설계인자들의 영향은 작게 나타났다. 상용해석프로그램을 이용하여 등가자기회로 결과와 비교를 하였으며, 대시포트 마운트를 제작하여 자극의 유효길이 변화에 대한 감쇠력의 변화를 실험적으로 비교하였다.

  • PDF

A Study of Wind-power Generations at the south-east coast of Ul-san (울산 남동부 해안지역에서의 소용량 풍력발전 가능성에 관한 연구)

  • Park, M.D.;Pack, M.S.;Lee, G.W.;Lee, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1392-1394
    • /
    • 2003
  • This paper presents the actual test data of 3 phase, 9 pole, 3.6 [kw] synchronized wind-power generator controlled by hinged vane system and the possibilities of the small mount wind-power generations at the south-east coast of Ul-san. It also shows the data of the wind-velocity acquired by wind-direction sensor, calculation and analysis of the estimated electrical generation power, energy storage systems, and the efficient usages of the wind-power system.

  • PDF