• Title/Summary/Keyword: Polarized current

Search Result 137, Processing Time 0.022 seconds

Properties analysis of environment friendly calcareous deposit films electrodeposited at various temperature conditions in natural seawater (천연해수 중 온도 변화에 따라 전착한 환경친화적인 석회질 피막의 특성 분석)

  • Lee, Chan-Sik;Kang, Jun;Lee, Myeong-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.779-785
    • /
    • 2015
  • Cathodic protection is recognized as the most cost-effective and technically appropriate corrosion prevention method for the submerged zone of offshore structures, ships, and deep-sea facilities. When cathodic protection is applied, the cathodic currents cause dissolved oxygen reduction, generating hydroxyl ions near the polarized surface that increase the interfacial pH and result in enhanced carbonate ion concentration and precipitation of an inorganic layer whose principal component is calcium carbonate. Depending on the potential, magnesium hydroxide can also precipitate. This mixed deposit is generally called "calcareous deposit." This layer functions as a barrier against the corrosive environment, leading to a decrease in current demand. Hence, the importance of calcareous deposits for the effective, efficient operation of marine cathodic protection systems is recognized by engineers and scientists concerned with cathodic protection in submerged marine environments. Calcareous deposit formation on a marine structure depends on the potential, current, pH, temperature, pressure, sea-water chemistry, flow, and time; deposit quality is significantly influenced by these factors. This study determines how calcareous deposits form in sea water, and assesses the interrelationship of formation conditions (such as the sea water temperature and surface condition of steel), deposited structure, and properties and the effectiveness of the cathodic protection.

Geophysical Logging of Frequency-domain Induced Polarization for Mineral Exploration (광물탐사를 위한 진동수영역 유도분극 물리검층)

  • Shin, Seungwook
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.3
    • /
    • pp.73-77
    • /
    • 2021
  • Induced polarization (IP) is useful for mineral exploration and hydrogeological studies by visualizing the electrochemical reactions at the interface between polarized minerals and groundwater. Frequency-domain IP (FDIP) is not actively applied to field surveys because it takes longer to acquire data, despite its higher data quality than conventional time-domain IP. However, data quality is more important in current mineral exploration as the targets gradually shift to deep or low-grade ore bodies. In addition, the measurement time reduced by automated instrumentation increases the potential for FDIP field applications. Therefore, we demonstrate that FDIP can detect mineral exploration targets by performing geophysical logging in the boreholes of a skarn deposit, in South Korea. Alternating current (AC) resistivity, percent frequency effect (PFE) and metal factor (MF) were calculated from impedance values obtained at two different frequencies. Skarn zones containing magnetite or pyrite showed relatively low AC resistivity, high PFE, and high MF compared to other zones. Therefore, FDIP surveys are considered to be useful for mineral exploration.

Risk Assessment Principle for Engineered Nanotechnology in Food and Drug

  • Hwang, Myung-Sil;Lee, Eun-Ji;Kweon, Se-Young;Park, Mi-Sun;Jeong, Ji-Yoon;Um, Jun-Ho;Kim, Sun-Ah;Han, Bum-Suk;Lee, Kwang-Ho;Yoon, Hae-Jung
    • Toxicological Research
    • /
    • v.28 no.2
    • /
    • pp.73-79
    • /
    • 2012
  • While the ability to develop nanomaterials and incorporate them into products is advancing rapidly worldwide, understanding of the potential health safety effects of nanomaterials has proceeded at a much slower pace. Since 2008, Korea Food and Drug Administration (KFDA) started an investigation to prepare "Strategic Action Plan" to evaluate safety and nano risk management associated with foods, drugs, medical devices and cosmetics using nano-scale materials. Although there are some studies related to potential risk of nanomaterials, physical-chemical characterization of nanomaterials is not clear yet and these do not offer enough information due to their limitations. Their uncertainties make it impossible to determine whether nanomaterials are actually hazardous to human. According to the above mention, we have some problems to conduct the human exposure risk assessment currently. On the other hand, uncertainty about safety may lead to polarized public debate and to businesses unwillingness for further nanotechnology investigation. Therefore, the criteria and methods to assess possible adverse effects of nanomaterials have been vigorously taken into consideration by many international organizations: the World Health Organization, the Organization for Economic and Commercial Development and the European Commission. The object of this study was to develop risk assessment principles for safety management of future nanoproducts and also to identify areas of research to strengthen risk assessment for nanomaterials. The research roadmaps which were proposed in this study will be helpful to fill up the current gaps in knowledge relevant nano risk assessment.

Electrochemical Study on Transfer Reaction of Ionizable Cefotiam across a Water/1,2-dichloroethane Interface and Drug Sensing Applications (물/1,2-Dichloroethane 계면에서 Cefotiam 약물 이온의 전이 반응 연구 및 약물 센서에 응용)

  • Liu, XiaoYun;Jeshycka, Shinta;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.581-588
    • /
    • 2018
  • In this article, electrochemical investigation of the transfer reaction of ionizable cefotiam (CTM), an antibiotic molecule across a polarized water/1,2-dichloroethane (water/1,2-DCE) interface was studied. Ion partition diagram providing the preferred charged form of CTM in either water or 1,2-DCE phase was established via the voltammetric evaluation of the transfer process of differently charged CTM species depending upon the pH variation of aqueous solutions. Thermodynamic information including the formal transfer potential and formal Gibbs transfer energy values in addition to important pharmacokinetics including partition coefficients of ionizable CTM were also evaluated. In particular, the current associated with the transfer of CTM present at pH 3.0 aqueous solution proportionally increased with respect to the CTM concentration which was further used for developing CTM sensitive ion sensor. In order to improve the portability and convenient usage, a single microhole interface fabricated in a supportive polyethylene terephthalate film was used of which hole was filled with a polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel replacing 1,2-DCE, a toxic organic solvent. A dynamic range of $1-10{\mu}M$ CTM was obtained.

Electrochemical Analysis and Applications of Tetracycline Transfer Reaction Process at Liquid/liquid Interfaces (액체/액체 계면에서 테트라사이클린 전이반응의 전기화학적 분석 및 응용)

  • Liu, XiaoYun;Han, Hye Youn;Goh, Eunseo;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.506-512
    • /
    • 2017
  • The transfer reaction characteristics of tetracycline (TC) across a polarized water/1,2-dichloroethane (1,2-DCE) interface was studied via controlling both pH and ionic strength of the aqueous phase in conjunction with cyclic and differential pulse voltammetries. Formal transfer potential values of differently charged TC ionic species at the water/1,2-DCE interface were measured as a function of pH values of the aqueous solution, which led to establishing an ionic partition diagram for TC. As a result, we could identify which TC ionic species are more dominant in the aqueous or organic phase. Thermodynamic properties including the formal transfer potential, partition coefficient and Gibbs transfer energy of TC ionic species at the water/1,2-DCE interface were also estimated. In order to construct an electrochemical sensor for TC, a single microhole supported water/polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel interface was fabricated. A well-defined voltammetric response associated with the TC ion transfer process was achieved at pH 4.0 similar to that of using the water/1,2-DCE interface. Also the measured current increased proportionally with respect to the TC concentration. A $5{\mu}M$ of TC in pH 4.0 buffer solution with a dynamic range from $5{\mu}M$ to $30{\mu}M$ TC concentration could be analyzed when using differential pulse stripping voltammetry.

Analysis of Electromagnetic Scattering by a Resistive Strip Grating with Tapered Resistivity on Dielectric Multilayers (다층 유전체위의 변하는 저항율을 가진 저항띠 격자구조에 의한 전자파 산란 해석)

  • Uei-Joong Yoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.5
    • /
    • pp.495-503
    • /
    • 1997
  • In this paper, the E-polarized electromagnetic scattering problems by a resistive strip grating with tapered resistivity on 3 dielectric layers are analyzed to find out the effects for the tapered resistivity of resistive strip and the relative permittivity and thickness of 3 die- lectric layers by applying the Fourier-Galerkin moment methods. The induced surface current density is expanded in a series of Jacobi-polynomial ${P^{(\chi,\beta)}}_p$(.) of the order $\alpha$= 0 and $\beta$=1 as a kind of orthogonal polyomians, and the tapered resistivity assumes to vary linearly from 0 at one edge to finite resistivity at the other edge. The normalized reflected and transmitted powers are obtained by varying the tapered resistivity and the relative permittivity and thickness of dielectric layers. The sharp variation points are observed when the higher order modes are transferred between propagating and evanescent modes, and in general the local minimum positions occur at less grating period for the more relative permittivity of dielectric layers. It should be noted that the patterns of the normalized reflected and transmitted powers for the tapered resistivity are very much different from those of the uniform resistivity and perfectly conducting cases. The proposed method of this paper cna solve the scattering problems for the tapered resistive, uniform resistive, and PEC strip cases.

  • PDF

A Study on Rehabilitation Treatment Using Radiofrequency Treatment (고주파 통증치료기를 이용한 재활 치료에 대한 연구)

  • Jo, Jae-Hyun;Lee, Sang-Yong;Lee, Geun-Yong;Yoon, Se-Jin;Cheong, Ha-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.212-218
    • /
    • 2020
  • When Radiofrequency energy is applied to the human body, the vibration width is very short. Therefore, the electrolyte burn generated when using the direct current does not occur. Ion molecules, polarized molecules, etc., vibrate more than 40,000 times per second, converting them into frictional heat to generate deep heat. The blood flow of capillaries increases 4-5 times more than at rest, increasing the supply of oxygen, nutrients, antibodies, and white blood cells. In addition, the electrochemical reaction does not occur because the vibration width and the pulsation period are very short. It is a physical factor treatment method that does not stimulate the sensory nerves and motor nerves. In this study, an isotonic exercise is performed in a young normal adult using a Radiofrequency pain treatment device. The purpose of this study is to integrate rehabilitation therapy by measuring electromyography data during isotonic exercise and confirming the effect on changes in motor neuron response. The EMG data generated when isotonic exercise of the forearm biceps muscle and the EMG data measured after the use of a Radiofrequency pain treatment device after exercise were RMS, respectively, and verified through t-test. It was confirmed that there was a significant difference in both men and women because the t-value was smaller than the significance level p (<.05).