• Title/Summary/Keyword: Point-of-Use

Search Result 5,822, Processing Time 0.035 seconds

Numerical solution of singular integral equation for multiple curved branch-cracks

  • Chen, Y.Z.;Lin, X.Y.
    • Structural Engineering and Mechanics
    • /
    • v.34 no.1
    • /
    • pp.85-95
    • /
    • 2010
  • In this paper, numerical solution of the singular integral equation for the multiple curved branch-cracks is investigated. If some quadrature rule is used, one difficult point in the problem is to balance the number of unknowns and equations in the solution. This difficult point was overcome by taking the following steps: (a) to place a point dislocation at the intersecting point of branches, (b) to use the curve length method to covert the integral on the curve to an integral on the real axis, (c) to use the semi-open quadrature rule in the integration. After taking these steps, the number of the unknowns is equal to the number of the resulting algebraic equations. This is a particular advantage of the suggested method. In addition, accurate results for the stress intensity factors (SIFs) at crack tips have been found in a numerical example. Finally, several numerical examples are given to illustrate the efficiency of the method presented.

Improvement of Pad Lifetime using POU (Point of Use) Slurry Filter and High Spray Method of De-Ionized Water (POU 슬러리 필터와 탈이온수의 고분사법에 의한 패드수명의 개선)

  • 박성우;김상용;서용진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.707-713
    • /
    • 2001
  • As the integrated circuit device shrinks to smaller dimensions, chemical mechanical polishing (CMP) process was requirdfo the global planarization of inter-metal dielectric (IMD) layer with free-defect. However, as the IMD layer gest thinner, micro-scratches are becoming as major defects. However, as the IMD layer gets thinner, micro-scratches are becoming as major defects. Micro-scratches are generated by agglomerated slurry, solidified and attached slurry in pipe line of slurry supply system. To prevent agglomerated slurry particle from inflow, we installed 0.5${\mu}{\textrm}{m}$ point of use (POU) filter, which is depth-type filter and has 80% filtering efficiency for the 1.0${\mu}{\textrm}{m}$ size particle. In this paper, we studied the relationship between defect generation and polished wafer counts to understand the exact efficiency fo the slurry filteration, and to find out the appropriate pad usage. Our experimental results showed that it sis impossible to prevent defect-causing particles perfectly through the depth-type filter. Thus, we suggest that it is necessary to optimize the slurry flow rate, and to install the high spray bar of de-ionized water (DIW) with high pressure, to overcome the weak-point of depth type filter.

  • PDF

DETECTION AND COUNTING OF FLOWERS BASED ON DIGITAL IMAGES USING COMPUTER VISION AND A CONCAVE POINT DETECTION TECHNIQUE

  • PAN ZHAO;BYEONG-CHUN SHIN
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.27 no.1
    • /
    • pp.37-55
    • /
    • 2023
  • In this paper we propose a new algorithm for detecting and counting flowers in a complex background based on digital images. The algorithm mainly includes the following parts: edge contour extraction of flowers, edge contour determination of overlapped flowers and flower counting. We use a contour detection technique in Computer Vision (CV) to extract the edge contours of flowers and propose an improved algorithm with a concave point detection technique to find accurate segmentation for overlapped flowers. In this process, we first use the polygon approximation to smooth edge contours and then adopt the second-order central moments to fit ellipse contours to determine whether edge contours overlap. To obtain accurate segmentation points, we calculate the curvature of each pixel point on the edge contours with an improved Curvature Scale Space (CSS) corner detector. Finally, we successively give three adaptive judgment criteria to detect and count flowers accurately and automatically. Both experimental results and the proposed evaluation indicators reveal that the proposed algorithm is more efficient for flower counting.

The estimation of camera's position and orientation using Hough Transform and Vanishing Point in the road Image (도로영상에서 허프변환과 무한원점을 이용한 카메라 위치 및 자세 추정 알고리즘)

  • Chae, Jung-Soo;Choi, Seong-Gu;Rho, Do-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.511-513
    • /
    • 2004
  • Camera Calibration should certain)y be achieved to take an accurate measurement using image system. Calibration is to prove the relation between an measurement object and camera and to estimate twelve internal and external parameters. In this paper, we suggest that an algorithm should estimate the external parameters from the road image and use a vanishing point's character from parallel straight lines in a space. also, we use Hough Transform to estimate an accurate vanishing point. Hough Transform has one of the advantages which is an application for each road environment. we assume a variety of environments to prove the usability of a suggested algorithm and show simulation results with a computer.

  • PDF

An Indoor Positioning Method using IEEE 802.11 Channel State Information

  • Escudero, Giovanni;Hwang, Jun Gyu;Park, Joon Goo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1286-1291
    • /
    • 2017
  • In this paper, we propose an indoor positioning system that makes use of the attenuation model for IEEE 802.11 Channel State Information (CSI) in order to determine its distance from an Access Point (AP) at a fixed position. With the use of CSI, we can mitigate the problems present in the use of Received Signal Strength Indicator (RSSI) data and increase the accuracy of the estimated mobile device's location. For the experiments we performed, we made use of the Intel 5300 Series Network Interface Card (NIC) in order to receive the channel frequency response. The Intel 5300 NIC differs from its counterparts in that it can obtain not only the RSSI but also the CSI between an access point and a mobile device. We can obtain the signal strengths and phases from subcarriers of a system which in turn means making use of this data in the estimation of a mobile device's position.

Estimating the Function Point for the Object Oriented Information Systems (객체지향 기반의 정보시스템 개발 프로젝트에서의 기능점수 예측 기법에 관한 연구)

  • Jeong, Seung-Ryul;Lee, Suk-Joon
    • The Journal of Information Systems
    • /
    • v.16 no.1
    • /
    • pp.111-133
    • /
    • 2007
  • The purpose of this study is to present a new function point estimation approach for the Object-Oriented information systems. In order to fulfill this purpose, we first review the literature on Function Point Analysis of IFPUG, Unified Modeling Language, and Unified Process. Then, we derive a method and rules for estimating Function Points based on Use Cases and Class Diagrams. To analyze the appropriateness of the proposed approach, we conduct the empirical testing. 143 use cases are collected from production, marketing, distribution, sales, and other areas from the Object-Oriented systems development projects. We compare our new approach with the existing methods that are usually used for traditional systems development projects. The results show that our proposed approach is more appropriate for the Object-Oriented environment.

  • PDF

A case study on verification of internet survey (인터넷 설문조사의 검증에 관한 사례연구)

  • Ryu, Gui-Yeol;Moon, Young-Soo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • The object of study is to verify the accuracy of internet survey by comparing database data and internet survey. Internet survey was conducted on August, 2012. Respondents were subscribers of KISTI NDSL. Variables were age, organization as demographic variables, number of use, and period of use as attitude variables. Mismatch rates of age, organization, number of use, and period, are 7.5%, 5%, 92%, and 55% respectively. We could estimate the mismatch rate for age as 3% as a pessimistic point of view, and 1% as an optimistic point of view by detail verification. The mismatch rates of organization are 4.5% as a pessimistic point of view, and 2% as an optimistic point of view. The mismatch rates for the frequency of use, the period of use are very high, because measurement error, problems in memory, and internet attitude, etc. Implication of this study is that data of internet survey could be reliable. Many further researches are needed for verification of internet survey.

Development of Pollutant Loading Estimation System using GIS (GIS를 이용한 유역별 오염부하량 산정시스템의 개발)

  • Ham, Kwang-Jun;Kim, Joon-Hyun;Shim, Jae-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.97-107
    • /
    • 2005
  • The purpose of this study is to develop a system, which estimates watershed pollutant loading rate through the combination of GIS and computational mode. Also, the applicability of this study was estimated by the application of the above system for Chuncheon City. The detailed results of these studies are as follows; The pollutant loading estimation system was developed for more convenient estimation of pollutant loading rate in watershed, and the system load was minimized by the separation of estimation module for point and non-point source. This system on the basis of GIS is very economical and efficient because it can be applied to other watershed with the watershed map. System modification is not needed. The pollutant loading estimation system for point source was developed to estimate the pollutant loading rate in watershed through the extraction of the proper data from all districts and yearly data and the execution of spatial analysis which is main function of GIS. From the verification result of spatial analysis, real watershed area and the administrative districtarea extracted by spatial analysis were $1,114,893,340.15m^2$ and $1,114,878,683.68m^2$, respectively. It shows that the spatial analysis results were very exact with only 0.001% error. The pollutant loading estimation system for non-point source was developed to calculate the pollutant loading rate through the overlaying of land-use and watershed map after the construction of new land-use map using the land register database with most exact land use classification. Application result for Chuncheon City shows that the proposed system results in one percent land use error while the statistical method results in five percent. More exact nonpoint source pollutant loading was estimated from this system.