• Title/Summary/Keyword: Pohang Light Source (PLS)

Search Result 47, Processing Time 0.04 seconds

Pohang Accelerator Laboratory and the 4th Generation Light Sourc (포항가속기연구소와 제4세대 방사광가속기)

  • Choi, Jin-Hyuk
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.547-555
    • /
    • 2006
  • The Pohang Light Source (PLS) of Pohang Accelerator Laboratory (PAL), which was constructed in 1994, is a 3rd generation synchrotron light source user facility. It consists of 2.5 GeV linear accelerator and a storage ring with circumference of 280 m. Presently, 27 beamlines around the storage ring are in operation providing synchrotron radiations to users. In addition, PAL has a construction project of the 4th generation light source. In this paper, the operation status of the PLS is described and the prospect of the 4th generation light source is reviewed.

Conceptual Design of PLS-II Control System for PLS (가속기 제어시스템의 성능향상을 위한 연구)

  • Yoon, J.C.;Lee, J.W.;Lee, E.H.;Ha, H.G.;Kim, J.M.;Park, S.J.;Kim, K.R.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1658_1659
    • /
    • 2009
  • PLS(Pohang Light Source) will begin the PLS-II project that has been funded by the KOREA Government in order to further upgrade the PLS which has operated since 1992. The control system of the PLS-II has distributed control architecture, with two layers of hierarchy; operator interface computer (OIC) layer and machine interface computer (MIC) layer. The OIC layer is based on SUN workstation with UNIX. A number of PC-based consoles allow to remotely operating the machine from the control room. PC-based consoles use the Linux or Windows operation system. Similar consoles in the experimental hall are used to control experiments. The MIC layer is directly interfaced to individual machine devices for low-level data acquisition and control. MIC layer is based on VMEbus standard with vxWorks real-time operating system. Executable application software modules are downloaded from host computers at the system start-up time. The MIC's and host computers are linked through Ethernet network. It should enable the use of hardware and software already developed for specific light source requirements. The core of the EPICS (Experimental Physics and Industrial Control System)[1] has been chosen as the basis for the control system software.

  • PDF

Design and Implementation of Solid-State Kicker Modulator for PLS-II (PLS-II 용 반도체 스위치 기반 키커 펄스 모듈레이터 설계 및 제작)

  • An, Suk-Ho;Kong, Hyung-Sup;Park, Wung-Hoa;Lee, Byung-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.307-308
    • /
    • 2019
  • The Pohang Light Source (PLS) - II is a 3 GeV third-generation synchrotron radiation facility. To inject electron beam from LINAC, a kicker modulator system and kicker magnets are installed in the PLS-II storage ring tunnel. The injected beam then falls into the storage ring beam dynamic aperture. This paper describes the design and implementation of the solid-state kicker modulator for PLS-II. The solid-state kicker modulator is consisted of high voltage solid state switch stacks. the technical considerations of the solid-state switch stacking for kicker modulator is discussed. The achieved capability of the solid-state kicker modulator demonstrates that is fulfills the design requirement of providing half-sine pulsed current of 10kA (peak), 6us (Base-width), with jitter < 2ns (Standard deviation). simulation and experimental results are presented to demonstrate the performance of the solid-state kicker modulator.

  • PDF

A Study of the linear accelerator electron gun upgrade for system design (선형가속기 Upgrade 전자총 시스템설계에 관한 연구)

  • Son, Yoon-Gyu;Park, Sung-Ju;Kim, Kyung-Ryul;Nam, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1373_1374
    • /
    • 2009
  • The PLS-II, the major upgrade program of the PLS (Pohang Light Source, a 2.5-GeV 3rd generation light source), is planned at the Pohang Accelerator Laboratory. Given the glaring lack of normative data regarding the PLS-II the major upgrade, this study can be seen as the first in a needed stream of research investigating selection by dual gun and dc electron gun. Usable electron gun can think method to use dual electron gun and method to prove energy by existing electron gun in energy increase. This article is concerned with the formal classification of used of pre-injector electron gun type of the DC and pulse. Design concept wishes to show contents that design for pulse type of power supply and DC type of electron gun.

  • PDF

Operation experience of 2 GeV PLS magnet power supplies (포항방사광가속기 2GeV 저장링용 전자석전원 장치의 운전경험)

  • Nam, Sang-H.;Jeong, Seong-H.;Han, Sung-H.;Suh, Jae-H.;Ha, Ki-M.;Yoon, Moo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.559-563
    • /
    • 1996
  • Total 215 magnet power supplies are under operation in Pohang Light Source(PLS). Current, voltage and peak power handling capabilities of DC power supply are in the range of 21 to 643V, 45 to 850A and 0.94 to 531KW, respectively. The DC power supplies can be categoriezed as uni-polar and bipolar power. Typical required stability and ripple of uni-polar power supplies are ${\pm}0.005%$ and ${\pm}0.05%$, respectively. The bipolar power supplies should be maintained within ${\pm}0.05%$ stability and ${\pm}0.5%$ ripple. Precise measurement results show that all power supplies meet or exceed the required specifications. The long term operation reliability to be sufficient for a stable operation of the Pohang Light Source.

  • PDF

The Development of PLS-II Storage-ring Girder Systems at PAL (방사광 가속기 PLS-II 저장링 거더 시스템 개발)

  • Kim, Seungnam;Lee, Chaesun;Lee, Honggi;Kim, Kwangwoo;Nam, Sanghun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.690-697
    • /
    • 2013
  • The magnets and vacuum chambers, which are the main facilities of the Pohang light source are installed on the storage-ring girders. System safety and reliability should be taken into account for the precise operating of the main facilities, so vibration analysis is essential to do this. Static and seismic analyses were performed for the design of structure considering safety, and also frequency and response spectrum analyses were performed for the precise alignment. With these results, the effects of surrounding vibration were checked. This paper explains about the design and vibration analysis of girder systems.

Development of Independent BPM Control System Using Reflective Memory at PLS (포항가속기의 Reflective Memory를 이용한 독립형 BPM 제어시스템 개발)

  • Yoon, J.C.;Lee, J.W.;Lee, E.H.;Kang, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1697-1698
    • /
    • 2008
  • PLS(Pohang Light Source) is 2.5 Gev synchrotron radiation source in Pohang, Korea, which is under operation since 1995. The hardware and software of the old BPM(Beam Position Monitor) data acquisition system for the PLS storage ring was completely upgraded to increase its performance and stability. The new BPM data acquisition system is based on VME-based EPICS (Experimental Physics and Instrument Control System) IOC system. We used 16-bit resolution analog-to-digital conversion board to digitize analog BPM signals. We developed a data average software to average raw BPM data using reflective memory board. We also developed device drivers for VME I/O boards used, IOC database for PV's(Process Variables). The new BPM data acquisition system is currently running for routine operation with good performance and stability. In this paper, we present the hardware and software of the new BPM data acquisition system DTL water skid cooling system and Resonant Control Cooling.

  • PDF

PLS-II separator the vacuum electron gun beam current emission test (PLS-II 전자총 진공이원화와 빔 전류 인출시험)

  • Son, Yoon-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1580-1581
    • /
    • 2011
  • The linear accelerator of Pohang Accelerator Laboratory(PAL) will drive a top-up mode operation in PLS-II(Pohang Light Source-II). Due to this kind of the operation mode, the electron gun is expected to have shorter life time of the cathode. Further in the PLS-II, two gate valves will be installed in front of the electron gun. The distance between the pre-bunching section and the electron gun will increase by 400 mm compared to the existing system due to the insertion of these gate valves. As a result the incident electron beam. One of the goals to improve the beam pulse width is by incorporating suitable biased voltage. In this paper, we will present test results of beam pulse width as a function of different biased voltage and focusing solenoid coil.

  • PDF

Optical design of soft X-ray region monochromator (Soft X-ray 영역 단색화 장치의 광학적 설계에 관한 연구)

  • 성면창;최원국;황정남;정광호;김영식
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.86-91
    • /
    • 1992
  • We describe the design of a soft X-ray grating monochromator for synchrotron radiation in the photon energy range 300~1200eV. We investigate the optimum condition in optical parameters of CEM (cylindrical element monochromator), whose performance is well known by Dragon beam line installed recently at Brookhaven National Laboratory by C. T. Chen, fitting the parameter of PLS (Pohang Light Source) storage ring construction.

  • PDF