• Title/Summary/Keyword: Platform switching

Search Result 83, Processing Time 0.029 seconds

Realization of single supply to reduce power on portable radiation detection device (소모전력 감소를 위한 단일 전원 휴대용 방사선 검출장치 구현)

  • Oh, Jae-Kyun;Nam, Hye-Jin;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.1024-1030
    • /
    • 2015
  • Safety and security system have been internationally enhanced in a field of shipping logistics. Accordingly, techniques for safety and security have been studied steadily. The need of portable radiation detection device is increasing by the search of the container is enhanced. In this paper, we propose a study to improve the life of the system and the realization of portable radiation detection device based on Cortex-A9. Configuration of a portable radiation detection device is configured largely to an analog board and the digital platform and the sensor module. The power used in each stage of the analog board is varied. Uses a switching regulator to use various power supply thereby to generate an error result and cause the switching noise. It is proposed to reduce the power consumption reducing technique for the study.

A Study on China's Intention to Switching to Shared Bike Platforms: Mechanisms of Trust and Distrust

  • Wenlong Lu;Yung Ho Suh;Sae Bom Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.179-187
    • /
    • 2023
  • Consumer trust plays a crucial role in the development of the sharing economy. This study primarily focuses on the factors influencing consumer trust and examines the case of ofo, a former leader in China's bike-sharing industry. This paper analyzes the decline in consumer trust in ofo, which can be attributed to internal management issues and the near-bankruptcy situation. The "difficulty in refunds" issue faced by ofo since December 2018 has been growing continuously, and this study explores the factors influencing trust and distrust in this context. By considering product factors (quality), platform factors (payment security, privacy protection, reputation), and social factors (social norms, government regulation) as independent variables, the study analyzes the factors affecting consumer trust. The analysis results revealed that as consumers' distrust towards shared bikes increases, their switching intention also increases. The company's reputation and social norms were found to influence both trust and distrust, while government regulation was found to influence trust. The research findings provide insights relevant to sharing economy platforms and offer guidance for future studies.

Narrow-diameter implants with conical connection for restoring the posterior edentulous region

  • Woo, In-Hee;Kim, Ju-Won;Kang, So-Young;Kim, Young-Hee;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.31.1-31.7
    • /
    • 2016
  • Background: The objective of this retrospective study was to show results from platform-switched narrow-diameter implants in the posterior edentulous region, which we followed up for more than 1 year after functional loading. Methods: Ninety-eight narrow implants were inserted into 66 patients. After healing, fixed implant-supported prostheses were delivered to the patients, and Periotest and radiographic examinations were performed. After the first year of loading, the implant outcome was again evaluated clinically and radiographically using the Periotest analysis. Crestal bone loss and Periotest values (PTVs) were used to evaluate the effect of surgery, prosthesis, implant, and a host-related factor. A general linear model was used to statistically detect variables statistically associated with crestal bone loss and Periotest value. Results: We followed up on the implants over 1 to 4 years after loading; their survival rate was 100 %, and pronounced differences from PTVs were noted among jaw location, bone quality, and loading period. No difference was detected in bone loss among the variables studied. Bone loss after functional loading was $0.14{\pm}0.39mm$. The stability value from the Periotest was $-3.29{\pm}0.50$. Conclusions: Within the limitations of this study, judicious use of platform-switched narrow implants with a conical connection must be considered an alternative for wide-diameter implants to restore a posterior edentulous region.

The influence of the implant-abutment complex on marginal bone and peri-implant conditions: A retrospective study

  • Tokgoz, Selen Ergin;Bilhan, Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.46-54
    • /
    • 2021
  • Purpose. The design of the implant-abutment complex is thought to be responsible for marginal bone loss (MBL) and might affect the condition of the peri-implant tissues. This the present study aimed to evaluate the influence of the implant-abutment complex on MBL and the peri-implant tissues in partially edentulous patients treated with dental implants and determine the most advantageous design. Materials and Methods. A total of ninety-one endosseous implants with different designs of implant-abutment complex [tissue level-TL (n = 30), platform switch-PS (n = 18), and platform match-PM (n = 43)] were reviewed for MBL, Probing Pocket Depth (PPD) and Bleeding on Probing (BoP). MBL was calculated for first year of the insertion and the following years. Results. The median MBL for the PM implants (2.66 ± 1.67 mm; n = 43) in the first year was significantly higher than those for the other types (P=.033). The lowest rate of MBL (0.61 ± 0.44 mm; n = 18) was observed with PS implants (P=.000). The position of the crown-abutment border showed a statistically significant influence (P=.019) and a negative correlation (r=-0.395) on MBL. BoP was found significantly higher in PM implants (P=.006). The lowest BoP scores were detected in PS implants, but the difference was not significant (P=.523). The relation between PPD and connection type revealed no statistically significant influence (P>.05). Conclusion. Within the limitations of the present study, it may be concluded that PS implants seem to show better peri-implant soft tissue conditions and cause less MBL.

An Implementation of the Network Synchronization Equipment on Optical Transmission Flatform and Impact Analysis of the Wander on NG-SDH Network (광전송플랫폼에서의 망동기장치 구현과 광전송망에 미치는 원더의 영향분석)

  • Yang, Choong-Reol;Ko, Je-Soo;Lee, Chang-Ki;Kim, Whan-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7A
    • /
    • pp.678-685
    • /
    • 2007
  • We implemented the network synchronization equipment for the optical transmission platform or next generation Packet/TDM(Time Division Multiplexing) data converged switching system and then, presented an impact of wander generation on the NG-SDH optical transmission network.

Design of a Variable-Stiffness Type Safety Joint for Service Robots (서비스 로봇용 가변강성 형 안전관절의 설계)

  • Jeong, Jae-Jin;Chang, Seung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.128-134
    • /
    • 2009
  • This paper aims to design a variable-stiffness type economical safety joint for service robots. The safety joint was designed to have a passive shock absorbing mechanism for protecting human from a catastrophic collision under service condition of robots. A simple mechanism composed of two action disks for switching the load transfer, a spring and a screw for pre-load was proposed. In order to evaluate the performance of the safety joint a testing platform which can carry out the static and impact tests was also designed and fabricated. From the test results, the designed safety joint was proved to have a variable load-carrying capacity and about 42% impact absorption capacity with simple manipulation of the control screw.

Path Planning of a Free Flying Object and its Application for Gymnastic Robots

  • Nam Taek-Kun;Kim Yong-Joo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.63-69
    • /
    • 2005
  • The motion of animals and gymnasts in the air as well as free flying space robots without thrusters are subjected to nonholonomic constraints generated by the law of conservation of angular momentum. The purpose of this paper is to derive analytical posture control laws for free flying objects in the air. We propose the bang-bang control method for trajectory planning of a 3 link mechanical system with initial angular momentum. This technique is used to reduce the DOF (degrees of freedom) at first switching phase and to determine the control inputs to steer the reduced order system to the desired position. Computer simulations for motion planning of an athlete approximated by 3 link, namely platform diving, are provided to verify the effectiveness of the proposed control scheme.

Low-Cost SVM-DTC Strategy of Induction Machine Drives Using Single DC-link Current Sensor

  • Wang, Wei;Cheng, Ming;Hua, Wei;Ding, Shichuan;Zhu, Ying;Zhao, Wenxiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.266-273
    • /
    • 2012
  • In conventional direct torque control (DTC) using space-vector modulation (SVM) of induction machine (IM) drives, at least three current sensors are needed. In this paper, a low-cost SVM-DTC strategy is proposed, in which only a single current sensor is used. The position of the voltage space vector is divided into two areas: effective and non-effective area. If it is located in the non-effective area, the voltage space vector will be shifted into the effective area with minimum distortion. Further, the switching frequency remains constant. The simulation is carried out on a MATLAB/Simulink platform and the simulated results verify the effectiveness of the proposed strategy.

Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants (임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향)

  • Yun, Bo-Hyeok;Shin, Hyon-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

Influencing Factors on Users' Resistance to the Mobile Easy Payment Services : Focusing on the Case of KakaoPay Users (모바일 간편결제 서비스에 대한 사용자 수용저항 요인 : 카카오페이 사용자를 중심으로)

  • Kim, Sodam;Park, Philip;Yang, Sung-Byung
    • Journal of Information Technology Services
    • /
    • v.16 no.2
    • /
    • pp.139-156
    • /
    • 2017
  • Since the global financial crisis of 2008, the continuous development and innovation in technology-related fields such as information and communications technology (ICT) are likely to swim against the recession. In this paradoxical situation, the necessity of financial innovation through ICT is on the rise. For this reason, the appearance of Fintech is more meaningful as a new converged industry with the potential to lead financial innovation. The term of Fintech is derived from combining 'Finance' and 'Technology.' In South Korea, one of the most popular types of Fintech is mobile payment. KakaoPay, which is the first mobile easy payment service in Korea, is a much more simplified type of mobile payment service than ones used in the past, and is provided by the most popular mobile messenger service in Korea, KakaoTalk. However, KakaoPay has few active users in spite of its many advantages, which include convenience, simplicity, and a powerful platform. Thus, the main purpose of this paper is to investigate influencing factors of user resistance on KakaoPay. In order to investigate specific factors, a research model is developed based on the unified understanding of user resistance put forth by Laumer and Eckhardt (2012). After gathering online survey data from KakaoTalk users, an empirical analysis is conducted to verify this research model. The results of this study give insights regarding user resistance factors in the Fintech sector, and by so doing, it is expected that the important factors of user resistance could help the diffusion of new services when new mobile payment services appear in the near future.