• Title/Summary/Keyword: Plate Spring

Search Result 240, Processing Time 0.038 seconds

Prediction of Radiated Noise From a Shaft-bearing-plate System Due to an Axial Excitation of Helical Gears (헬리컬 기어의 축방향 가진에 의한 축-베어링-플레이트계의 방사소음 예측)

  • Park, Chan-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.199-203
    • /
    • 2004
  • In this paper, a simplified model is studied to predict analytically the radiated noise from the helical gear system due to an axial excitation of helical gear. The simplified model describes gear, shaft, bearing, and housing. To obtain the axial force of helical gear, mesh stiffness is calculated in the load deflection relation. The axial force is obtained from the solution of the equation of motion, using the mesh stiffness. It is used as a longitudinal excitation of the shaft, which in turn drives the gear housing through the bearing. In this study, the shaft is modeled as a rod, while the bearing is modeled as a parallel spring and damper only supporting longitudinal forces. The gear housing is modeled as a clamped circular plate with viscous damping. For the modeling of this system, transfer function from the shaft to the clamped plate are used, using a spectral method with four pole parameters. Out-of-plane displacement for the thin circular plate with viscous damping is derived and sound pressure radiated from the plate is also derived. Using the model, parameter studies are carried out.

  • PDF

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

Flaw Analysis Based Life Assessment of Welded Tubular Joint (결함해석에 기초한 배관용접부 수명평가)

  • Lee, Hyeong-Il;Han, Tae-Su;Jeong, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.5 s.176
    • /
    • pp.1331-1342
    • /
    • 2000
  • In power generation systems a variety of structural components typically operate at high temperature and pressure. Therefore a life assessment methodology accounting for gradual creep fracture is increasingly needed for these components. The most critical defects in such structure are generally found in the form of semi-elliptical surface cracks in the welded tubular joints. Therefore the analysis of a semi-elliptical surface crack in a plate or a shell is an important problem in engineering fracture mechanics. On this background, via shell/line-spring finite element analyses of such surface cracks in the welded T and L joints under various loadings, we investigate J-integral along the crack front We first develop T and L joints auto mesh generation program providing ABAQUS input file composed of shell/line-spring finite elements. We then further develop a T and L joints life assessment program based on the experimental creep crack growth law and auto mesh generation program in a graphical user interface format Finally the remaining life of T and L joints for various analytical parameters are assessed using the developed life assessment program.

Development of a Torsion Joint Yoke for Motor-Driven Power Steering System Using a Double-Action Extrusion Process (더블-액션 압출공정을 적용한 전동조향장치용 토션조인트 요크 개발)

  • Kim, H.M.;Kim, Y.K.;Park, Y.B.
    • Transactions of Materials Processing
    • /
    • v.21 no.8
    • /
    • pp.473-478
    • /
    • 2012
  • The yoke, a component of conventional motor-driven power steering system, often contains welding defects from its manufacturing process. To eliminate these defects, the precision cold forging process has been tried. In this study, the double-action complex forging has been used to manufacture a torsion joint yoke. The backward extrusion proved faster than the forward extrusion in forging of the product. The double-action complex forging process utilized an upper die composed of a punch, a punch guide, a disc spring and a coil spring. The forged material pushes up the punch guide, and then the disc spring and the coil spring balances the backward extrusion force. Consequently, the flow of material was essentially in the forward direction, resulting in a successful forging operation. The forging load of Al 6061-T6 was higher than that of the automotive structural hot rolled plate.

Simulation of Plate Deformation due to Triangle Heating Using Inherent Strain Method (고유변형도법을 이용한 삼각가열에 의한 판 변형의 시뮬레이션)

  • Jang, Chang-Doo;Ko, Dae-Eun;Ha, Yun-Sok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.703-709
    • /
    • 2008
  • In the shipyard, line heating and triangle heating are two major processes for forming curved plates in various shapes. While there have been many studies on line heating, triangle heating has been rarely studied due to its complicated heating process with irregular multi-heating paths and highly concentrated heat input. As the triangle heating process is one of the most labor-consuming jobs in shipyards, it is essential to study the automation as well as improvement of triangle heating process in order to increase hull forming productivity. In this study, a pioneering attempt to simulate triangle heating was made. A circular disk-spring model was proposed for elasto-plastic analysis procedure of triangle heating and the inherent strain method was also used to analyze the deformation of plates. Simulation results were compared with those of experiments and showed good agreement. It is shown that the present approach including analysis model used in this study is effective to simulate the triangle heating for plate forming process in shipbuilding.

Experimental Study on Performance Evaluation of Steel Frame with Buckling Control Brace (좌굴제어 가새를 가진 가새골조의 성능향상에 관한 실험적 연구)

  • Lee, Sang-Ju;Han, Sang-Eul;Noh, Sam-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.181-188
    • /
    • 2007
  • This research presents two methods to prevent local buckling from circular tube brace and then verify their performance capacity through a cyclic loading test. As control methods on local buckling, one is to restrict local buckling as attaching cover plate at range of buckling. And the another is to exclude danger of buckling as inserting contraction device with rod and spring at the center of brace. The purpose of this research is to develop structural device for restriction of local buckling or for exclusion of its. And we investigate appliance of suggested methods through an experiment. We also estimate the improvement of performance capacity in a quantitative respect.

Development of Metaal Bipolar plates for Fuel Cell Vehicles (연료전지 차량용 금속분리판 개발)

  • Jin, Sang-Mun;Yang, Yoo-Chang;Kim, Sae-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.331-334
    • /
    • 2009
  • Currently, the bipolar plates are fabricated mainly from graphite materials. However, metal bipolar plate are getting most attractive due to their good feasibility of mass production and low cost. In this study, metal bipolar plates for fuel cell Vehicles were developed with a concept based on the straight flow patterns to minimize the pressure drop and spring back. And molded gasket apply to the bipolar plate for improve sealing performance. Results show that the metal bipolar plate have a high potential to replace for graphite materials in fuel cell application.

  • PDF

A dynamic foundation model for the analysis of plates on foundation to a moving oscillator

  • Nguyen, Phuoc T.;Pham, Trung D.;Hoang, Hoa P.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.6
    • /
    • pp.1019-1035
    • /
    • 2016
  • This paper proposes a new foundation model called "Dynamic foundation model" for the dynamic analysis of plates on foundation subjected to a moving oscillator. This model includes a linear elastic spring, shear layer, viscous damping and the special effects of mass density parameters of foundation during vibration. By using finite element method and the principle of dynamic balance, the governing equation of motion of the plate travelled by the oscillator is derived and solved by the Newmark's time integration procedure. The accuracy of the algorithm is verified by comparing the numerical results with the other numerical results in the literature. Also, the effects of mass and damping ratio of system components, stiffness of suspension system, velocity of moving oscillator, and dynamic foundation parameters on dynamic responses are investigated. A very important role of these factors will be shown in the dynamic behavior of the plate.

Weldability of Dissimilar Metal Plates with YAG Laser (YAG 레이저에 의한 이종금속판재의 접합특성)

  • 이지환
    • Journal of Welding and Joining
    • /
    • v.6 no.1
    • /
    • pp.21-27
    • /
    • 1988
  • This paper describes weldability of dissimilar metal plates with YAG laser for the use of a small-size electronic spring parts. Effects of welding conditions, combination of plates, thickness of upper plate are examined in relation to welding strength and microstructure of welded region. The obtained results are summarized as follows. Welding defects such as cavity and crack showed a tendency to easily occur in the case where 1) pulse duration is short, 2) laser power is high, 3) PBS plate with high thermal diffusivity is used for lower plate. Among these defects, the occurrence of cavity cased a drop of welding strength. This results from the reduction of welding area between upper and lower plates. In SK-5/SUS304 plates (thickness: 0.2/0.4mm/, welding strength was the highest in welding conditions: laser power is 30J/pulse, pulse duration 9ms, amount of defocus +2mm.

  • PDF

Comparative Study on Detecting Methods for Total Coliform in Sewage Effluent (하수 방류수에서 대장균군의 검출방법의 비교)

  • Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.422-427
    • /
    • 2007
  • The purposes of this study were to investigate the concentration of total coliforms in sewage effluents during the period from August 2004 to October 2005. The removal efficiency range of multi-tube method and plate count method were $31.3{\sim}99.5%$ and $66.8{\sim}99.2%$, respectively. Though a correlation between the multi-tube method and the plate count method in the same sample is low, not only is an experimental procedure very simple, but the time required also is short. The seasonal correlation between methods showed more sensitive spring and summer than autumn and winter. So the study indicated plate count method can be used in rapid and reliance identification of total coliform more than the multi-tube method.