• Title/Summary/Keyword: Plasmon resonance

Search Result 322, Processing Time 0.02 seconds

Sensing of the Insecticide Carbofuran Residues by Surface Plasmon Resonance and Immunoassay (표면플라즈몬공명과 효소면역분석법을 이용한 살충제 카보후란 잔류물 검출)

  • Yang G. M.;Cho N. H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.6 s.113
    • /
    • pp.333-339
    • /
    • 2005
  • The pesticide is raising public interest in the world, because it causes damage to an environmental pollution and the human health remaining agricultural products and an ecosystem, in spite of the advantages. Particularly, each country restricts the residual pesticide and induces observance about the safety and usage standard so that they can control the amount of pesticide used and defend the safety of agricultural products. The habitual practice for the analysis of the residual pesticide depends on GC (gas chromatography), HPLC (high performance liquid chromatography) and GC/MS (gas chromatography/mass spectroscopy), which triturate the fixed quantity of samples, abstract and purify as a suitable organic solvent. These methods have the highly efficient in aspects of sensitivity and accuracy. On the other hand, they need the high cost, time consuming, much effort, expensive equipment and the skillful management. Carbofuran is highly toxic by inhalation and ingestion and moderately toxic by dermal absorption. As with other carbamate compounds, it is metabolized in the liver and eventually excreted in the urine. The half-life of carbofuran on crops is about 4 days when applied to roots, and longer than 4 days if applied to the leaves. This research was conducted to develop immunoassay for detecting carbofuran residue quickly on the basis of surface plasmon resonance and to evaluate the measurement sensitivity. Gold chip used was CM5 spreaded dextran on the surface. An applied antibody to Immunoassay was GST (glutathione-s-transferase). The association and the dissociation time were 176 second and 215 second between GST and carbofuran. The total analysis time using surface plasmon resonance was 13 minutes including regeneration time, on the other hand HPLC and GC/MS was 2 hours usually. The minimum detection limit of a permissible amount for carbofuran in the country is 0.1 ppm. The immunoassay method using surface plasmon resonance was 0.002 ppm.

SPR-based Antibody-Antigen Interaction for Real Time Analysis of Carbamate Pesticide Residues

  • Yang, Gil-Mo;Kang, Suk-Won
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.15-19
    • /
    • 2008
  • This research was conducted to develop a quick and sensitive method of detecting carbamate residues using the immobilization of antibody-antigen interactions with surface plasmon resonance (SPR). We have used commercialized surface plasmon resonance equipment (Biacore 3000). The antibody used for the immunoassay was specific for glutathione-s-transferase (GST) and the antigens included several carbamate pesticides (carbofuran, carbaryl, and benfuracarb). When antigens were applied to the protein GST, the detection limit was 2 ng/mL of carbamate pesticide. The fabricated protein GST maintained its activity for over 200 measurements. Thus we determined that the SPR biosensors could detect the specific reversible binding of a reactant in solution to a binding partner immobilized on the surface of the sensor and allow real-time detection and monitoring.

Detection of Multi-class Pesticide Residues Using Surface Plasmon Resonance Based on Polyclonal Antibody

  • Yang, Gil-Mo;Kang, Suk-Won
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.547-552
    • /
    • 2008
  • The detection of carbamate (carbofuran, carbaryl, benfracarb, thiodicarb, and methomil) and organophosphate (diazinon, cadusafos, ethoprofos, parathion-methyl, and chlorpyrifos) pesticide residues with very low detection limits was carried out using surface plasmon resonance (SPR) based equipment. The capacity to develop a portable SPR biosensor for food safety was also investigated. The applied ligand for the immunoassays was polyclonal goat anti-rabbit immunoglobulin (IgG) peroxidase conjugate. Concentration tests using direct binding assays showed the possibility of quantitative analysis. For ligand fishing to find a proper antibody to respond to each pesticide, acetylcholinesterase (AChE), and glutathione-S-transferase (GST) were tested. The reproducibility and precision of SPR measurements were evaluated. With this approach, the limit of detection for pesticide residues was 1 ng/mL and analysis took less than 11 min. Thus, it was demonstrated that detecting multi-class pesticide residues using SPR and IgG antibodies provides enough sensitivity and speed for use in portable SPR biosensors.

Characteristics of a Bimetal-Layer Chip of a Surface Plasmon Resonance Sensor in the Intensity Interrogation for Tumor Marker Detection

  • Kim, Hyungjin;Kim, Chang-duk;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.243-246
    • /
    • 2016
  • The characteristics of a bimetallic surface plasmon resonance (SPR) chip were investigated to detect a tumor biomarker, carcinoembryonic antigen (CEA). The linewidth and the tangential slope of the reflectance curve of the bimetallic SPR chip was compared with those of the reflectance curve of a conventional gold (Au) SPR chip. The changes in reflectance in response to the variation in CEA in the critical concentration range were analyzed at an angle where the tangential slope of the reflectance curve was maximum. From linear regression analysis, the sensitivity of the bimetallic SPR chip with respect to the CEA in critical concentration was obtained.

Classification of Measurement Methods of Surface Plasmon Resonance Biosensors by SK Index (SK 지수를 이용한 표면 플라즈몬 공명 바이오 센서의 측정방법의 분류)

  • Lee, Seung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.342-349
    • /
    • 2004
  • SK (SPR Kinds) index, which can categorize the complicated measurement methods of surface plasmon resonance by simple method, has been proposed and verified. SK index is composed of three digits, where each digit presents the type of immobilized ligand, the type of illumination and the kinds of varying parameter, sequentially. The measurement method of (33#) series among SK indices shows the possibility of the multi-sensing capability, by which the response of 2-dimensional array of immobilized ligands can be detected simultaneously. The proposed possibility of multi-sensing capability has been verified by the modeling that is based on Fresnel reflection model.

Optical Characteristics of Bimetallic Silver-Gold Film Structure in Surface Plasmon Resonance Sensor Applications (표면 플라즈몬 공명 센서에서의 쌍금속 은-금 박막 구조의 광학 특성)

  • Gwon, Hyuk-Rok;Lee, Seong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.156-160
    • /
    • 2007
  • Surface plasmon resonance(SPR) has been widely studied for biological and chemical sensing applications. The present study conducts numerical simulation for the single and bimetallic layer SPR configurations by using the multiple beam interference matrix(MBIM) method to investigate the influence of wave interference and complex refractive indices of materials on optical characteristics such as reflectance and optical phase shift which are used for sensing. First, calculated reflectances are compared with experimental data for validation. In addition, in the single film structures this study finds out the appropriate film thicknesses with minimum reflectance for cases of gold film and silver film. For a bimetallic silver-gold film structure, in particular, the bimetallic film thicknesses that has the minimum reflectance are found 36 nm for silver and 5 nm for gold. From the results, the use of phase shift would be useful compared to reflectance in determining the SPR configuration because the phase shift becomes more sensitive than reflectance.

Design of multi-layered surface plasmon resonance sensors using optical admittance method and evolution algorithm (광학 어드미턴스 기법과 진화 알고리즘 기법을 이용한 다층 표면 플라즈몬 공명 센서의 설계)

  • Jung, Jae-Hoon;Lee, Seung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.402-408
    • /
    • 2005
  • This paper describes the optimal design of a multi-layered surface plasmon resonance sensors to meet various specifications and improve some physical parameters. Dip 3 dB bandwidth and depth were chosen as design parameters and the objective function was the norm of the difference between design parameters and target values. The design variables are thicknesses of each layer and to obtain the design parameters, the optical admittance method was employed. The (1+1) evolution strategy was employed as an optimization tool. By applying the proposed optimization procedure to a 3-layered sensor, the optimized design variables considerably improved the 3 dB bandwidth by 4.8 nm and the dip depth by 1.1 dB.

Development and evaluation of surface plasmon resonance imaging for the detection of antibodies against classical swine fever virus in swine

  • Cho, Ho-Seong;Lee, Tae-Uk;Park, Nam-Yong
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.2
    • /
    • pp.205-209
    • /
    • 2007
  • A protein chip based on surface plasmon resonance (SPR) imaging was developed for measuring classical swine fever virus (CSFV) antibody using a recombinant gp55 protein as an antigen. The diagnostic potential of SPR imaging for detecting antibodies to the CSFV gp55 protein was compared with that of a enzyme -linked immunosorbent assay (ELISA) using 70 pig sera. There was a strong positive correlation between the SPR imaging and ELISA (n=70, r=0.916, p<0.01). Therefore, the SPR imaging, which is a label-free and high-through put method, is expected to be a valuable tool in the serodiagnosis of CSFV.

Sensitivity Enhancement of Surface Plasmon Resonance Biosensor with Colloidal Gold

  • Kibong Choi;Hee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.3 no.1
    • /
    • pp.19-23
    • /
    • 1998
  • We enhanced the sensitivity of surface plasmon resonance biosensor by the conversion of the real-time direct binding immunoassay into the sandwich immunoassay, in which colloidal gold particles coated with anti-mouse IgG was used. By the immobilization of anti-mouse IgG onto the carboxymethyl dextran surface of thin gold film, the direct binding of analyte(mouse IgG) onto the sensor chip, and the injection of colloidal gold particles coated with anti-mouse IgG, about 100 times of sensitivity enhancement was obtained. This result suggests that nanoparticles, which has a high refractive index, homogeneous ultrafine structure and capability of size control, would be applicable for the detection of very small quantity of biomaterial.

  • PDF

Characterization of gold nanoparticles on optical fiber for localized surface plasmon resonance sensor (광섬유 국소화 표면 플라즈몬 공명 센서를 위한 광섬유 표면상의 금 나노 입자 특성 분석)

  • Lee, Hoon;Lee, Seung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.226-233
    • /
    • 2009
  • In this study, the optical properties of localized surface plasmon resonance sensor using optical fiber was analyzed as the variation of a size and surface density of gold nano particles on the etched optical fiber surface. It is shown that a size and surface density of gold nano particles on optical fiber surface are controlled by $Na_3$ citrate quantity and pH of gold colloid solution. To measure the sensitivity, peak wavelength of absorbance spectrum was detected as the reflective index of the solution. The sensor sensitivity is linearly dependent on the size and surface densities of gold nano particles from the results of optical experiments.